The DOI matches its Crossref record; 23 of the 23 references it cites were found in a registry or an index.
Formulation and Acoustic Studies of a New Phase-Shift Agent for Diagnostic and Therapeutic Ultrasound
Open accessAbstract
Recent efforts in the area of acoustic droplet vaporization with the objective of designing extravascular ultrasound contrast agents has led to the development of stabilized, lipid-encapsulated nanodroplets of the highly volatile compound decafluorobutane (DFB). We developed two methods of generating DFB droplets, the first of which involves condensing DFB gas (boiling point from -1.1 to -2 °C) followed by extrusion with a lipid formulation in HEPES buffer. Acoustic droplet vaporization of micrometer-sized lipid-coated droplets at diagnostic ultrasound frequencies and mechanical indices were confirmed optically. In our second formulation methodology, we demonstrate the formulation of submicrometer-sized lipid-coated nanodroplets based upon condensation of preformed microbubbles containing DFB. The droplets are routinely in the 200-300 nm range and yield microbubbles on the order of 1-5 μm once vaporized, consistent with ideal gas law expansion predictions. The simple and effective nature of this methodology allows for the development of a variety of different formulations that can be used for imaging, drug and gene delivery, and therapy. This study is the first to our knowledge to demonstrate both a method of generating ADV agents by microbubble condensation and formulation of primarily submicrometer droplets of decafluorobutane that remain stable at physiological temperatures. Finally, activation of DFB nanodroplets is demonstrated using pressures within the FDA guidelines for diagnostic imaging, which may minimize the potential for bioeffects in humans. This methodology offers a new means of developing extravascular contrast agents for diagnostic and therapeutic applications.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Handbook of Chemistry and Physics.
(1973) · Annals of Internal Medicine · doi:10.7326/0003-4819-79-6-934_3 · Cited by 2,559
Regulation of transport pathways in tumor vessels: Role of tumor type and microenvironment
Hobbs, S. K., Monsky, W. L., Yuan, F., Roberts, W. G., Griffith, L., Torchilin, V. P., & Jain, R. K. (1998) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.95.8.4607 · Cited by 2,438
Acoustic droplet vaporization for therapeutic and diagnostic applications
Kripfgans, O. D., Fowlkes, J. B., Miller, D. L., Eldevik, O. P., & Carson, P. L. (2000) · Ultrasound in Medicine & Biology · doi:10.1016/s0301-5629(00)00262-3 · Cited by 572
Controlled and targeted tumor chemotherapy by ultrasound-activated nanoemulsions/microbubbles
Rapoport, N. Y., Kennedy, A. M., Shea, J. E., Scaife, C. L., & Nam, K.-H. (2009) · Journal of Controlled Release · doi:10.1016/j.jconrel.2009.05.026 · Cited by 551
Microbubble-enhanced US in Body Imaging: What Role?
Wilson, S. R., & Burns, P. N. (2010) · Radiology · doi:10.1148/radiol.10091210 · Cited by 470
Alexandridis, P., Athanassiou, V., Fukuda, S., & Hatton, T. A. (1994) · Langmuir · doi:10.1021/la00020a019 · Cited by 356
Decafluorobutane as a Phase-Change Contrast Agent for Low-Energy Extravascular Ultrasonic Imaging
Sheeran, P. S., Wong, V. P., Luois, S., McFarland, R. J., Ross, W. D., Feingold, S., Matsunaga, T. O., & Dayton, P. A. (2011) · Ultrasound in Medicine & Biology · doi:10.1016/j.ultrasmedbio.2011.05.021 · Cited by 244
Self-citationThe role of inertial cavitation in acoustic droplet vaporization
Fabiilli, M. L., Haworth, K. J., Fakhri, N. H., Kripfgans, O. D., Carson, P. L., & Fowlkes, J. B. (2009) · IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control · doi:10.1109/tuffc.2009.1132 · Cited by 232
On the acoustic vaporization of micrometer-sized droplets
Kripfgans, O. D., Fabiilli, M. L., Carson, P. L., & Fowlkes, J. B. (2004) · The Journal of the Acoustical Society of America · doi:10.1121/1.1755236 · Cited by 221
Anderson, C. R., Hu, X., Zhang, H., Tlaxca, J., Declèves, A.-E., Houghtaling, R., Sharma, K., Lawrence, M., Ferrara, K. W., & Rychak, J. J. (2011) · Investigative Radiology · doi:10.1097/rli.0b013e3182034fed · Cited by 219
Cited by
State-of-the-art materials for ultrasound-triggered drug delivery
Sirsi, S. R., & Borden, M. A. (2014) · Advanced Drug Delivery Reviews · doi:10.1016/j.addr.2013.12.010 · Cited by 488
Wilson, K., Homan, K., & Emelianov, S. (2012) · Nature Communications · doi:10.1038/ncomms1627 · Cited by 442
Ultrasound Localization Microscopy and Super-Resolution: A State of the Art
Couture, O., Hingot, V., Heiles, B., Muleki-Seya, P., & Tanter, M. (2018) · IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control · doi:10.1109/tuffc.2018.2850811 · Cited by 423
Gas-Mediated Cancer Bioimaging and Therapy
Chen, L., Zhou, S.-F., Su, L., & Song, J. (2019) · ACS Nano · doi:10.1021/acsnano.9b04954 · Cited by 343
Ultrasound-responsive systems as components for smart materials
Athanassiadis, A. G., Ma, Z., Moreno-Gomez, N., Melde, K., Choi, E., Goyal, R., & Fischer, P. (2022) · Chemical Reviews · doi:10.1021/acs.chemrev.1c00622 · Cited by 293
Design of ultrasonically-activatable nanoparticles using low boiling point perfluorocarbons
Sheeran, P. S., Luois, S. H., Mullin, L. B., Matsunaga, T. O., & Dayton, P. A. (2012) · Biomaterials · doi:10.1016/j.biomaterials.2012.01.021 · Cited by 254
Self-citationPhase-Change Contrast Agents for Imaging and Therapy
S. Sheeran, P., & A.Dayton, P. (2012) · Current Pharmaceutical Design · doi:10.2174/138161212800099883 · Cited by 253
Ultrasound nanotheranostics in fighting cancer: Advances and prospects
Zhou, L.-Q., Li, P., Cui, X.-W., & Dietrich, C. F. (2020) · Cancer Letters · doi:10.1016/j.canlet.2019.11.034 · Cited by 112
Metadata
- Authors
- Sheeran, P. S., Luois, S., Dayton, P. A., & Matsunaga, T. O.
- Venue
- Langmuir
- Publisher
- American Chemical Society (ACS)
- Published
- 2011-07-28
- Volume
- 27
- Issue
- 17
- Pages
- 10412-10420
- ISSN
- 0743-7463 (ISSN-L)
- 1520-5827
- OpenAlex
- W2058379099
- Cited by
- 309
- References
- 23
- FWCI
- 12.03
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.