Highly Sensitive Detection of Target ssDNA Based on SERS Liquid Chip Using Suspended Magnetic Nanospheres as Capturing Substrates
The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Abstract
A new approach for sensitive detection of a specific ssDNA (single-stranded DNA) sequence based on the surface enhanced Raman spectroscopy (SERS) liquid chip is demonstrated. In this method, the probe DNA (targeting to one part of target ssDNA) was attached to the nano-SERS-tags (poly(styrene-co-acrylic acid)/(silver nanoparticles)/silica composite nanospheres), and the capture DNA (targeting to the other part of target ssDNA) was attached to the Fe3O4/poly(acrylic acid) core/shell nanospheres. The nano-SERS-tags with probe DNA were first allowed to undergo hybridization with the target ssDNA in solution to achieve the best efficiency. Subsequently, the magnetic composite nanospheres with capture DNA were added as the capturing substrates of the target ssDNA combined with the nano-SERS-tags. Upon attraction with an external magnet, the nanospheres (including the nano-SERS-tags) were deposited together due to the hybridization, and the deposit sediment was then analyzed by SERS. Quantitative detection of target ssDNA was achieved based on the well-defined linear correlation between the SERS signal intensity and the target ssDNA quantity in the range of 10 nM to 10 pM, and the limit of detection was approximately 10 pM. Multiplexed detection of up to three different ssDNA targets in one sample was demonstrated using three different types of nano-SERS-tags under a single excitation laser. The experimental results indicated that the liquid-phase DNA sequencing method, thus named the SERS liquid chip (SLC) method, holds significant promises for specific detection of trace targets of organisms.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
In vivo tumor targeting and spectroscopic detection with surface-enhanced Raman nanoparticle tags
Qian, X., Peng, X.-H., Ansari, D. O., Yin-Goen, Q., Chen, G. Z., Shin, D. M., Yang, L., Young, A. N., Wang, M. D., & Nie, S. (2008) · Nature Biotechnology · doi:10.1038/nbt1377 · Cited by 2,201
Cited by
Plasmon-enhanced optical sensors: a review
Li, M., Cushing, S. K., & Wu, N. (2015) · The Analyst · doi:10.1039/c4an01079e · Cited by 1,011
Liu, M., Wang, Z., Zong, S., Chen, H., Zhu, D., Wu, L., Hu, G., & Cui, Y. (2014) · ACS Applied Materials & Interfaces · doi:10.1021/am5006282 · Cited by 178
Ngo, H. T., Gandra, N., Fales, A. M., Taylor, S. M., & Vo-Dinh, T. (2016) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2016.01.073 · Cited by 135
“…has been investigated widely (Cao et al. 2002; Fabris et al. 2007; Faulds et al. 2008; Gao et al. 2013; He et al. 2011; Hu et al. 2010; Kang et al. 2010; Li et al. 2012; Li et al. 2013b; Ngo et al. 2014a; Ngo et al. 2014b; Ngo et al. 2013, 2015; Qi et al. 2014; Sun et al. 2007; Xu et al. 2015).”
MethodInfluentialNgo, H. T., Freedman, E., Odion, R. A., Strobbia, P., De Silva Indrasekara, A. S., Vohra, P., Taylor, S. M., & Vo-Dinh, T. (2018) · Scientific Reports · doi:10.1038/s41598-018-21615-3 · Cited by 66
Metadata
- Authors
- Li, J.-M., Ma, W.-F., You, L.-J., Guo, J., Hu, J., & Wang, C.-C.
- Venue
- Langmuir
- Publisher
- American Chemical Society (ACS)
- Published
- 2013-05-09
- Volume
- 29
- Issue
- 20
- Pages
- 6147-6155
- ISSN
- 0743-7463 (ISSN-L)
- 1520-5827
- OpenAlex
- W1992140499
- Cited by
- 46
- References
- 1
- FWCI
- 3.41
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).