Thermocapillary Motion of a Liquid Drop on a Horizontal Solid Surface
The DOI matches its Crossref record; 5 of the 5 references it cites were found in a registry or an index.
Abstract
The motion of drops of decane on horizontal poly(dimethylsiloxane) (PDMS)-coated glass surfaces resulting from a temperature gradient on the surface is studied experimentally, and a theoretical description of the thermocapillary motion of spherical-cap drops on a horizontal solid surface obtained using the lubrication approximation also is presented. The drop size and the applied temperature gradient are varied in the experiments, and the measured velocities of the drops are compared with predictions from the model. The scalings of the velocity with drop size and with the applied temperature gradient are predicted correctly by the theoretical model, even though the actual velocities are smaller than those predicted. The influence of contact angle hysteresis, which leads to a critical drop size below which drops do not move, is found to be minimal. Unlike in previous studies (Chen, J. Z.; Troian, S. M.; Darhuber, A. A.; Wagner, S. J. Appl. Phys. 2005, 97, 014906; Brzoska, J. B.; Brochard-Wyart, F.; Rondelez, F. Langmuir 1993, 9, 2220), this small critical drop size appears to be independent of the applied temperature gradient. Results also are presented on the deformation of the contact lines of the moving drops in the form of an aspect ratio, and correlated with the temperature difference across the footprints of the drops and the capillary number.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
de Gennes, P. G. (1985) · Reviews of Modern Physics · doi:10.1103/revmodphys.57.827 · Cited by 7,207
The dynamics of the spreading of liquids on a solid surface. Part 1. Viscous flow
Cox, R. G. (1986) · Journal of Fluid Mechanics · doi:10.1017/s0022112086000332 · Cited by 1,435
Darhuber, A. A., Valentino, J. P., Troian, S. M., & Wagner, S. (2003) · Journal of Microelectromechanical Systems · doi:10.1109/jmems.2003.820267 · Cited by 240
Polystyrene Layers Grafted to Macromolecular Anchoring Layer
Iyer, K. S., Zdyrko, B., Malz, H., Pionteck, J., & Luzinov, I. A. (2003) · Macromolecules · doi:10.1021/ma034460z · Cited by 142
Motion of droplets along thin fibers with temperature gradient
Yarin, A. L., Liu, W., & Reneker, D. H. (2002) · Journal of Applied Physics · doi:10.1063/1.1459099 · Cited by 92
Cited by
Soft Actuators for Small-Scale Robotics
Hines, L., Petersen, K., Lum, G. Z., & Sitti, M. (2017) · Advanced Materials · doi:10.1002/adma.201603483 · Cited by 1,337
Thermal non-equilibrium transport in colloids
Würger, A. (2010) · Reports on Progress in Physics · doi:10.1088/0034-4885/73/12/126601 · Cited by 433
Manipulation of droplets in microfluidic systems
Yang, C.-G., Xu, Z.-R., & Wang, J.-H. (2010) · TrAC Trends in Analytical Chemistry · doi:10.1016/j.trac.2009.11.002 · Cited by 158
Metadata
- Authors
- Pratap, V., Moumen, N., & Subramanian, R. S.
- Venue
- Langmuir
- Publisher
- American Chemical Society (ACS)
- Published
- 2008-04-10
- Volume
- 24
- Issue
- 9
- Pages
- 5185-5193
- ISSN
- 0743-7463 (ISSN-L)
- 1520-5827
- OpenAlex
- W2028015001
- Cited by
- 158
- References
- 5
- FWCI
- 6.65
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.