The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Kinetic Aspects of Emulsion Stabilization by Surfactants: A Microfluidic Analysis
Abstract
In classical emulsification processes, surfactants play two roles: first, they reduce the interfacial tension, facilitating droplet deformation and rupture, and second, they reduce droplet coalescence. Here, we use a microfluidic emulsification system to completely uncouple these two processes, allowing stabilization against coalescence to be studied quantitatively and independently of droplet formation. We demonstrate that, in addition to the classical effect of stabilization by an increase of surfactant concentration, the dynamics of adsorption of surfactant at the water-oil interface is a key element for droplet stabilization. Microfluidic emulsification devices can therefore be tailored to improve emulsification while decreasing the concentration of surfactant by increasing the time before the droplets first come into contact.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
The origins and the future of microfluidics
Whitesides, G. M. (2006) · Nature · doi:10.1038/nature05058 · Cited by 9,687
Cited by
Single-cell analysis and sorting using droplet-based microfluidics
Mazutis, L., Gilbert, J., Ung, W. L., Weitz, D. A., Griffiths, A. D., & Heyman, J. A. (2013) · Nature Protocols · doi:10.1038/nprot.2013.046 · Cited by 1,355
Self-citationPassive and active droplet generation with microfluidics: a review
Zhu, P., & Wang, L. (2017) · Lab on a Chip · doi:10.1039/c6lc01018k · Cited by 1,238
Microdroplets in Microfluidics: An Evolving Platform for Discoveries in Chemistry and Biology
Theberge, A. B., Courtois, F., Schaerli, Y., Fischlechner, M., Abell, C., Hollfelder, F., & Huck, W. T. S. (2010) · Angewandte Chemie International Edition · doi:10.1002/anie.200906653 · Cited by 1,059
Seemann, R., Brinkmann, M., Pfohl, T., & Herminghaus, S. (2012) · Reports on Progress in Physics · doi:10.1088/0034-4885/75/1/016601 · Cited by 1,049
Surfactants in droplet-based microfluidics
Baret, J.-C. (2012) · Lab Chip · doi:10.1039/c1lc20582j · Cited by 649
Self-citationDroplets and Bubbles in Microfluidic Devices
Anna, S. L. (2016) · Annual Review of Fluid Mechanics · doi:10.1146/annurev-fluid-122414-034425 · Cited by 582
Droplet microfluidics: A tool for biology, chemistry and nanotechnology
Mashaghi, S., Abbaspourrad, A., Weitz, D. A., & van Oijen, A. M. (2016) · TrAC Trends in Analytical Chemistry · doi:10.1016/j.trac.2016.05.019 · Cited by 374
Moragues, T., Arguijo, D., Beneyton, T., Modavi, C., Simutis, K., Abate, A. R., Baret, J.-C., deMello, A. J., Densmore, D., & Griffiths, A. D. (2023) · Nature Reviews Methods Primers · doi:10.1038/s43586-023-00212-3 · Cited by 316
Self-citationDroplets Formation and Merging in Two-Phase Flow Microfluidics
Gu, H., Duits, M. H. G., & Mugele, F. (2011) · International Journal of Molecular Sciences · doi:10.3390/ijms12042572 · Cited by 312
Ho, T. M., Razzaghi, A., Ramachandran, A., & Mikkonen, K. S. (2022) · Advances in Colloid and Interface Science · doi:10.1016/j.cis.2021.102541 · Cited by 253
Grenoble, Z., & Trabelsi, S. (2018) · Advances in Colloid and Interface Science · doi:10.1016/j.cis.2018.08.003 · Cited by 120
Digital PCR: From early developments to its future application in clinics
Trouchet, A., Gines, G., Benhaim, L., & Taly, V. (2025) · Lab on a Chip · doi:10.1039/d5lc00055f · Cited by 43
Metadata
- Authors
- Baret, J.-C., Kleinschmidt, F., El Harrak, A., & Griffiths, A. D.
- Venue
- Langmuir
- Publisher
- American Chemical Society (ACS)
- Published
- 2009-03-18
- Volume
- 25
- Issue
- 11
- Pages
- 6088-6093
- ISSN
- 0743-7463 (ISSN-L)
- 1520-5827
- OpenAlex
- W2027794151
- Cited by
- 234
- References
- 1
- FWCI
- 9.12
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.