CoChat

Interactions between Polymer-Grafted Membranes in Concentrated Solutions of Free Polymer

Evans, E., Klingenberg, D. J., Rawicz, W., Szoka, F. · 1996 · Langmuir
Cited by 50

The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.

Abstract

Polymers grafted or otherwise immobilized at surfaces are often used to stabilize particle suspensions in situations where nonspecific colloidal forces or specific chemical bonds act to coagulate the particles. Although the motivation is clear, criteria for steric stabilization are not well established for environments that contain large amounts of free polymer which can induce strong attraction through depletion forces. To examine these criteria, we have performed micromechanical tests of adhesion between pairs of large vesicles with membranes made from mixtures of phospholipids and phospholipids grafted with poly(ethylene oxide) PEO chains in aqueous solutions of free (nonadsorbing) PEO chains. Solutions were made with two free polymer fractions ( N p ≈ 114 and 444 monomers in average length) over a large range of volume fractions between 0.01 and 0.2. Three graft chain lengths ( N g ≈ 45, 114, and 273 monomers) and several surface densities were used to extend the scale of surface roughness from ∼0.5 nm for smooth bilayers to nearly 16 nm for the most prominent graft. On the basis of established theory, the grafted polymers were expected to form structures that varied from dilute noninteracting chains to semidilute marginal brushes with mean volume fractions of up to 0.06. Surprisingly, we found a consistent pattern of interaction for all graft lengths and surface densities; i.e., there was no adhesion below a threshold level of free polymer concentration and adhesion energy increased strongly with free polymer concentration above the threshold. Moreover, there was no tendency toward stabilization even at the highest volume fractions of 0.15−0.2. When both surfaces carried grafts ( symmetric interactions), the stabilization threshold was proportionally higher than when one of the two surfaces was bare ( asymmetric interactions). Significantly, these features were independent of free and graft polymer molecular weights. Correlation of the energy scale for free polymer depletion at the threshold to the graft surface density and symmetry of the steric interaction implies a simple criterion for stabilization of surfaces grafted with homopolymers in semidilute solutions of nonadsorbing free polymer and good solvent.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1021/la9509559

Cites

1 of 1 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Cited by

See all 50

Metadata

Authors
Evans, E., Klingenberg, D. J., Rawicz, W., & Szoka, F.
Venue
Langmuir
Published
1996-01-01
Volume
12
Issue
12
Pages
3031-3037
ISSN
  • 0743-7463 (ISSN-L)
  • 1520-5827
OpenAlex
W2031280010
Cited by
50
References
1
FWCI
2.60
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.