Interactions between Polymer-Grafted Membranes in Concentrated Solutions of Free Polymer
The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Abstract
Polymers grafted or otherwise immobilized at surfaces are often used to stabilize particle suspensions in situations where nonspecific colloidal forces or specific chemical bonds act to coagulate the particles. Although the motivation is clear, criteria for steric stabilization are not well established for environments that contain large amounts of free polymer which can induce strong attraction through depletion forces. To examine these criteria, we have performed micromechanical tests of adhesion between pairs of large vesicles with membranes made from mixtures of phospholipids and phospholipids grafted with poly(ethylene oxide) PEO chains in aqueous solutions of free (nonadsorbing) PEO chains. Solutions were made with two free polymer fractions ( N p ≈ 114 and 444 monomers in average length) over a large range of volume fractions between 0.01 and 0.2. Three graft chain lengths ( N g ≈ 45, 114, and 273 monomers) and several surface densities were used to extend the scale of surface roughness from ∼0.5 nm for smooth bilayers to nearly 16 nm for the most prominent graft. On the basis of established theory, the grafted polymers were expected to form structures that varied from dilute noninteracting chains to semidilute marginal brushes with mean volume fractions of up to 0.06. Surprisingly, we found a consistent pattern of interaction for all graft lengths and surface densities; i.e., there was no adhesion below a threshold level of free polymer concentration and adhesion energy increased strongly with free polymer concentration above the threshold. Moreover, there was no tendency toward stabilization even at the highest volume fractions of 0.15−0.2. When both surfaces carried grafts ( symmetric interactions), the stabilization threshold was proportionally higher than when one of the two surfaces was bare ( asymmetric interactions). Significantly, these features were independent of free and graft polymer molecular weights. Correlation of the energy scale for free polymer depletion at the threshold to the graft surface density and symmetry of the steric interaction implies a simple criterion for stabilization of surfaces grafted with homopolymers in semidilute solutions of nonadsorbing free polymer and good solvent.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Hydration forces between phospholipid bilayers
Rand, R. P., & Parsegian, V. A. (1989) · Biochimica et Biophysica Acta (BBA) - Reviews on Biomembranes · doi:10.1016/0304-4157(89)90010-5 · Cited by 1,125
Cited by
Polyester Dendritic Systems for Drug Delivery Applications: Design, Synthesis, and Characterization
Ihre, H. R., Padilla De Jesús, O. L., Szoka, & Fréchet, J. M. J. (2002) · Bioconjugate Chemistry · doi:10.1021/bc010102u · Cited by 332
Lipid membranes with grafted polymers: physicochemical aspects
Marsh, D., Bartucci, R., & Sportelli, L. (2003) · Biochimica et Biophysica Acta (BBA) - Biomembranes · doi:10.1016/s0005-2736(03)00197-4 · Cited by 232
“These results establish a parsimonious criterion for stabilisation of vesicle surfaces grafted with homopolymers [6].”
BackgroundResultInfluentialJohnson-Kendall-Roberts Theory Applied to Living Cells
Chu, Y.-S., Dufour, S., Thiery, J. P., Perez, E., & Pincet, F. (2005) · Physical Review Letters · doi:10.1103/physrevlett.94.028102 · Cited by 219
Kierstead, P. H., Okochi, H., Venditto, V. J., Chuong, T. C., Kivimae, S., Fréchet, J. M. J., & Szoka, F. C. (2015) · Journal of Controlled Release · doi:10.1016/j.jconrel.2015.06.023 · Cited by 210
Self-citationMultifunctional Role of Polyvinylpyrrolidone in Pharmaceutical Formulations
Luo, Y., Hong, Y., Shen, L., Wu, F., & Lin, X. (2021) · AAPS PharmSciTech · doi:10.1208/s12249-020-01909-4 · Cited by 195
Designer lipids for drug delivery: From heads to tails
Kohli, A. G., Kierstead, P. H., Venditto, V. J., Walsh, C. L., & Szoka, F. C. (2014) · Journal of Controlled Release · doi:10.1016/j.jconrel.2014.04.047 · Cited by 167
“By forming a steric barrier around the liposome, PEG-modified lipids embedded in a lipid bilayer decrease interactions with serum opsonins, cellular ligands/receptors and other preexisting serum factors [22] while reducing adhesion to other membrane surfaces [23].”
BackgroundSelf-citationKaizuka, Y., & Machida, R. (2025) · eLife · doi:10.7554/elife.101175.3 · Cited by 2
Kaizuka, Y., & Machida, R. (2025) · eLife · doi:10.7554/elife.101175
Metadata
- Authors
- Evans, E., Klingenberg, D. J., Rawicz, W., & Szoka, F.
- Venue
- Langmuir
- Publisher
- American Chemical Society (ACS)
- Published
- 1996-01-01
- Volume
- 12
- Issue
- 12
- Pages
- 3031-3037
- ISSN
- 0743-7463 (ISSN-L)
- 1520-5827
- OpenAlex
- W2031280010
- Cited by
- 50
- References
- 1
- FWCI
- 2.60
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.