The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Nanometer-Scale Surface Properties of Mixed Phospholipid Monolayers and Bilayers
Abstract
Mixed distearoylphosphatidylethanolamine (DSPE) and dioleoylphosphatidylethanolamine (DOPE) monolayers and bilayers have been deposited on mica using the Langmuir−Blodgett (LB) technique, as a model system for biomembranes. Investigation with atomic force microscopy revealed phase-separation for both monolayers in air and bilayers in water in the form of microscopic DSPE domains embedded in a DOPE matrix. For the monolayers in air, the step height measured between the higher DSPE phase and the lower DOPE phase was larger than expected from the molecular lengths, and a significant contrast in adhesion and friction was observed despite identical lipid end groups. This unexpected behavior resulted primarily from a difference in the film mechanical properties, the DOPE phase being inelastically deformed by the probe. For the bilayers in water, similar trends were found in terms of height, adhesion, and friction, but an additional short-range repulsive hydration/steric force over the DSPE phase contributed to the observed differences.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Hydration forces between phospholipid bilayers
Rand, R. P., & Parsegian, V. A. (1989) · Biochimica et Biophysica Acta (BBA) - Reviews on Biomembranes · doi:10.1016/0304-4157(89)90010-5 · Cited by 1,125
Cited by
AFM: a versatile tool in biophysics
Alessandrini, A., & Facci, P. (2005) · Measurement Science and Technology · doi:10.1088/0957-0233/16/6/r01 · Cited by 384
Yuan, C., Furlong, J., Burgos, P., & Johnston, L. J. (2002) · Biophysical Journal · doi:10.1016/s0006-3495(02)75596-3 · Cited by 313
Feldman, K., Hähner, G., Spencer, N. D., Harder, P., & Grunze, M. (1999) · Journal of the American Chemical Society · doi:10.1021/ja991049b · Cited by 279
Chemical and Biochemical Analysis Using Scanning Force Microscopy
Takano, H., Kenseth, J. R., Wong, S.-S., O'Brie, J. C., & Porter, M. D. (1999) · Chemical Reviews · doi:10.1021/cr9801317 · Cited by 259
Sample preparation procedures for biological atomic force microscopy
EL KIRAT, K., BURTON, I., DUPRES, V., & DUFRENE, Y. F. (2005) · Journal of Microscopy · doi:10.1111/j.1365-2818.2005.01480.x · Cited by 130
Metadata
- Authors
- Dufrêne, Y. F., Barger, W. R., Green, J.-B. D., & Lee, G. U.
- Venue
- Langmuir
- Publisher
- American Chemical Society (ACS)
- Published
- 1997-09-01
- Volume
- 13
- Issue
- 18
- Pages
- 4779-4784
- ISSN
- 0743-7463 (ISSN-L)
- 1520-5827
- OpenAlex
- W2093315204
- Cited by
- 232
- References
- 1
- FWCI
- 3.94
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Nanometer-Scale Surface Properties of Mixed Phospholipid Monolayers and Bilayers. https://app.cochat.ai/papers/10.1021/la970221r
- The paper
- Dufrêne, Y. F., Barger, W. R., Green, J.-B. D., & Lee, G. U. (1997). Nanometer-Scale Surface Properties of Mixed Phospholipid Monolayers and Bilayers. Langmuir. https://doi.org/10.1021/la970221r
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.