Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 1,428

The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.

Application of Large Pore MCM-41 Molecular Sieves To Improve Pore Size Analysis Using Nitrogen Adsorption Measurements

Kruk, M., Jaroniec, M., Sayari, A.·1997·Langmuir

Abstract

MCM-41 siliceous molecular sieves were used to test the applicability of the Kelvin equation for nitrogen adsorption in cylindrical pores of the size from 2 to 6.5 nm. It was shown that the Kelvin equation for the hemispherical meniscus, corrected for the statistical film thickness, is in quite good agreement with an experimental relation between the pore size and the capillary condensation pressure. The agreement can be made quantitative in the pore size range from ca. 2 to 6.5 nm, if a simple correction to the Kelvin equation is introduced. The required statistical film thickness curve ( t -curve) was calculated using nitrogen adsorption data for large pore MCM-41 samples and the obtained results were extrapolated using an adsorption isotherm for a macroporous silica gel. Moreover, an accurate analytical representation of the t -curve was found. Since both the corrected Kelvin equation for cylindrical pores and the t -curve have simple analytical forms, they can conveniently be used in a variety of methods to evaluate porosity. It was shown that the BJH method with the corrected Kelvin equation accurately reproduces pore sizes of MCM-41 materials. A comparison was made between the specific surface areas for the MCM-41 samples calculated on the basis of the BET equation and those obtained using other independent methods. The results strongly suggest that when nitrogen adsorption data are used, the BET method overestimates the specific surface area of siliceous materials. The latter conclusion was supported by the examination of the obtained statistical film thickness curve.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1021/la970776m

Cites

2 of 2 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 2 references

Cited by

See all 1,428

Metadata

Authors
Kruk, M., Jaroniec, M., & Sayari, A.
Venue
Langmuir
Published
1997-11-01
Volume
13
Issue
23
Pages
6267-6273
ISSN
  • 0743-7463 (ISSN-L)
  • 1520-5827
OpenAlex
W2039241045
Cited by
1,428
References
2
FWCI
26.47
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Application of Large Pore MCM-41 Molecular Sieves To Improve Pore Size Analysis Using Nitrogen Adsorption Measurements. https://app.cochat.ai/papers/10.1021/la970776m
The paper
Kruk, M., Jaroniec, M., & Sayari, A. (1997). Application of Large Pore MCM-41 Molecular Sieves To Improve Pore Size Analysis Using Nitrogen Adsorption Measurements. Langmuir. https://doi.org/10.1021/la970776m

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.