Ultrahydrophobic and Ultralyophobic Surfaces: Some Comments and Examples
Abstract
The preparation of ultrahydrophobic and ultralyophobic surfaces using several techniques is described. Plasma polymerization of 2,2,3,3,4,4,4-heptafluorobutyl acrylate on poly(ethylene terephthalate) yields surfaces with water contact angles of θ A /θ R = 174°/173°. Argon plasma etching of polypropylene in the presence of poly(tetrafluoroethylene) renders surfaces with water contact angles as high as θ A /θ R = 172°/169°. Surfaces of compressed pellets of submicrometer, variable-diameter spherical particles of PTFE oligomers exhibit water contact angles of θ A /θ R = 177°/177°, methylene iodide contact angles of θ A /θ R = 140°/138°, and hexadecane contact angles of θ A /θ R = 140°/125°. We emphasize that contact angle hysteresis is more important in characterizing lyophobicity than is the maximum achievable contact angle. These surfaces are rough at the micrometer and submicrometer scales, and water drops roll easily on all of them. We make an intuitive argument that the topology of the roughness is important and controls the continuity of the three-phase contact line and thus the hysteresis. We also report smooth ultralyophobic surfaces that are prepared by silanization of silicon wafers with Cl(SiMe 2 O) n SiMe 2 Cl ( n = 0, 1, 2, and 3), (Me 3 SiO) 3 SiCH 2 CH 2 Si(CH 3 ) 2 Cl, and (Me 3 SiO) 2 Si(CH 3 )CH 2 CH 2 Si(CH 3 ) 2 Cl. These surfaces exhibit much lower contact angles but little or no hysteresis, and droplets of water, hexadecane and methylene iodide slide easily off them. We propose that these covalently attached monolayers are flexible and liquidlike and that droplets in contact with them experience very low energy barriers between metastable states.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Wettability of porous surfaces
Cassie, A. B. D., & Baxter, S. (1944) · Transactions of the Faraday Society · doi:10.1039/tf9444000546 · Cited by 13,807
RESISTANCE OF SOLID SURFACES TO WETTING BY WATER
Wenzel, R. N. (1936) · Industrial & Engineering Chemistry · doi:10.1021/ie50320a024 · Cited by 13,316
Chaudhury, M. K., & Whitesides, G. M. (1991) · Langmuir · doi:10.1021/la00053a033 · Cited by 658
Cited by
Superhydrophobic surfaces: from structural control to functional application
Zhang, X., Shi, F., Niu, J., Jiang, Y., & Wang, Z. (2008) · J. Mater. Chem. · doi:10.1039/b711226b · Cited by 1,768
Bioinspired Surfaces with Superwettability: New Insight on Theory, Design, and Applications
Wang, S., Liu, K., Yao, X., & Jiang, L. (2015) · Chemical Reviews · doi:10.1021/cr400083y · Cited by 1,646
Stable Superhydrophobic Coatings from Polyelectrolyte Multilayers
Zhai, L., Cebeci, F. Ç., Cohen, R. E., & Rubner, M. F. (2004) · Nano Letters · doi:10.1021/nl049463j · Cited by 916
Evidence for self-cleaning in gecko setae
Hansen, W. R., & Autumn, K. (2005) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0408304102 · Cited by 601
Copper sulphide (CuxS) as an ammonia gas sensor working at room temperature
Sagade, A. A., & Sharma, R. (2008) · Sensors and Actuators B: Chemical · doi:10.1016/j.snb.2008.02.015 · Cited by 276
Metadata
- Authors
- Chen, W., Fadeev, A. Y., Hsieh, M. C., Öner, D., Youngblood, J., & McCarthy, T. J.
- Venue
- Langmuir
- Publisher
- American Chemical Society (ACS)
- Published
- 1999-04-24
- Volume
- 15
- Issue
- 10
- Pages
- 3395-3399
- ISSN
- 0743-7463 (ISSN-L)
- 1520-5827
- OpenAlex
- W2084807890
- Cited by
- 1,190
- References
- 3
- FWCI
- 10.62
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Ultrahydrophobic and Ultralyophobic Surfaces: Some Comments and Examples. https://app.cochat.ai/papers/10.1021/la990074s
- The paper
- Chen, W., Fadeev, A. Y., Hsieh, M. C., Öner, D., Youngblood, J., & McCarthy, T. J. (1999). Ultrahydrophobic and Ultralyophobic Surfaces: Some Comments and Examples. Langmuir. https://doi.org/10.1021/la990074s
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.