Mechanical Properties of Cross-Linked Synthetic Elastomeric Polypentapeptides
The DOI matches its Crossref record.
Abstract
Mechanical properties in equilibrium swelling states were examined for two elastomeric polypentapeptides, namely, (GVGVP) 251 and (GVGIP) 260 where G = glycine, V = valine, P = proline, and I = isoleucine. They had been prepared using recombinant DNA technology and cross-linked by γ-irradiation over the range of doses from 6 to 30 Mrad. Moduli were measured in uniaxial tensile tests. The specific work of fracture was determined as a measure of toughness. Increased doses of γ-radiation increased the moduli (cross-link density) of hydrogels. The hydrophobic folding and assembly phase transition that occurred on raising the temperature was demonstrated to have significant effects on moduli and fracture properties. Thermoelasticity experiments suggest that the phase transition involves changes in elasticity mechanism. Above the transition temperature, hydrogels were shown to become more viscoelastic.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Designing materials for biology and medicine
Langer, R., & Tirrell, D. A. (2004) · Nature · doi:10.1038/nature02388 · Cited by 3,198
“Urry and co-workers have shown over many years that simple repeating polypeptides related to elastin can be engineered to exhibit mechanical behaviour reminiscent of the intact protei”
BackgroundRheological properties of peptide-based hydrogels for biomedical and other applications
Yan, C., & Pochan, D. J. (2010) · Chemical Society Reviews · doi:10.1039/b919449p · Cited by 800
Yilgör, I., Yilgör, E., & Wilkes, G. L. (2015) · Polymer · doi:10.1016/j.polymer.2014.12.014 · Cited by 654
Elastin as a biomaterial for tissue engineering
Daamen, W. F., Veerkamp, J. H., van Hest, J. C. M., & van Kuppevelt, T. H. (2007) · Biomaterials · doi:10.1016/j.biomaterials.2007.06.025 · Cited by 518
Mithieux, S. M., & Weiss, A. S. (2005) · Advances in Protein Chemistry · doi:10.1016/s0065-3233(05)70013-9 · Cited by 511
Applications of elastin-like polypeptides in tissue engineering
Nettles, D. L., Chilkoti, A., & Setton, L. A. (2010) · Advanced Drug Delivery Reviews · doi:10.1016/j.addr.2010.04.002 · Cited by 350
Peptide-based biopolymers in biomedicine and biotechnology
Chow, D., Nunalee, M. L., Lim, D. W., Simnick, A. J., & Chilkoti, A. (2008) · Materials Science and Engineering: R: Reports · doi:10.1016/j.mser.2008.04.004 · Cited by 327
Smart and genetically engineered biomaterials and drug delivery systems
Kopeček, J. (2003) · European Journal of Pharmaceutical Sciences · doi:10.1016/s0928-0987(03)00164-7 · Cited by 292
Independent Control of Rigidity and Toughness of Polymeric Hydrogels
Kong, H. J., Wong, E., & Mooney, D. J. (2003) · Macromolecules · doi:10.1021/ma034137w · Cited by 224
Responsive Polymers at the Biology/Materials Science Interface
Alexander, C., & Shakesheff, K. M. (2006) · Advanced Materials · doi:10.1002/adma.200502640 · Cited by 195
Protein engineering approaches to biomaterials design
Maskarinec, S. A., & Tirrell, D. A. (2005) · Current Opinion in Biotechnology · doi:10.1016/j.copbio.2005.06.009 · Cited by 178
Hydrogels for Musculoskeletal Tissue Engineering
Varghese, S., & Elisseeff, J. H. (2006) · Advances in Polymer Science · doi:10.1007/12_072 · Cited by 173
Metadata
- Authors
- Lee, J., Macosko, C. W., & Urry, D. W.
- Venue
- Macromolecules
- Publisher
- American Chemical Society (ACS)
- Published
- 2001-07-20
- Volume
- 34
- Issue
- 17
- Pages
- 5968-5974
- ISSN
- 0024-9297 (ISSN-L)
- 1520-5835
- OpenAlex
- W1995844621
- Cited by
- 92
- References
- 0
- FWCI
- 1.60
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.