The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
In-Situ Thermoreversible Gelation of Block and Star Copolymers of Poly(ethylene glycol) and Poly(N-isopropylacrylamide) of Varying Architectures
Abstract
We report the development of a new gelation mechanism and a new family of polymers that self-assembles to form gels in a thermoreversible fashion. The polymers are block or star copolymers with a central hydrophilic poly(ethylene glycol) (PEG) segment (A) and temperature responsive poly( N -isopropylacrylamide) (PNIPAAm) terminal segments (B). Copolymers of various architectures, AB, A(B) 2, A(B) 4, and A(B) 8, were synthesized to investigate the structures and properties relationship. At 5 °C, the viscosities of 20 wt % solutions were between 700 and 950 cP, and they could be easily injected through a 25 G needle. Upon warming to body temperature, A(B) 2, A(B) 4, and A(B) 8 formed a strong associative network gel with aggregates of PNIPAAm segments acting as physical cross-links, whereas AB formed a weaker gel by micellar packing and entanglement. The values of elastic modulus, loss tangent, and yield strength were 1000−2500 Pa, 0.24−0.62, and 200−860 Pa, respectively. The gelation kinetic was fast; a typical gelation time for a solution of 5 mL in volume was less than a minute. No significant syneresis was observed after 2 months at 37 °C. DSC results indicated that the thermal behavior of material was completely reversible even after 30 heat-and-cool cycles. These materials are promising candidates for in-situ gelation applications such as injectable drug delivery, tissue engineering scaffolds, and anatomical barriers.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
The Physics of Block Copolymers
Hamley, I. W. (1998) · doi:10.1093/oso/9780198502180.001.0001 · Cited by 1,913
Cited by
Stimuli-reponsive polymers and their bioconjugates
GIL, E., & HUDSON, S. (2004) · Progress in Polymer Science · doi:10.1016/j.progpolymsci.2004.08.003 · Cited by 2,385
Thermosensitive sol-gel reversible hydrogels
Jeong, B., Kim, S. W., & Bae, Y. H. (2002) · Advanced Drug Delivery Reviews · doi:10.1016/s0169-409x(01)00242-3 · Cited by 1,478
In situ-forming hydrogels--review of temperature-sensitive systems
Ruel-Gariépy, E., & Leroux, J.-C. (2004) · European Journal of Pharmaceutics and Biopharmaceutics · doi:10.1016/j.ejpb.2004.03.019 · Cited by 1,297
Thermosensitive sol–gel reversible hydrogels
Jeong, B., Kim, S. W., & Bae, Y. H. (2012) · Advanced Drug Delivery Reviews · doi:10.1016/j.addr.2012.09.012 · Cited by 533
Responsive reversible hydrogels from associative “smart” macromolecules
Tsitsilianis, C. (2010) · Soft Matter · doi:10.1039/b923947b · Cited by 278
Metadata
- Authors
- Lin, H.-H., & Cheng, Y.-L.
- Venue
- Macromolecules
- Publisher
- American Chemical Society (ACS)
- Published
- 2001-04-24
- Volume
- 34
- Issue
- 11
- Pages
- 3710-3715
- ISSN
- 0024-9297 (ISSN-L)
- 1520-5835
- OpenAlex
- W2012281486
- Cited by
- 235
- References
- 1
- FWCI
- 2.40
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.