Student or educator? Sign up with your school email and get 6 months of Pro free.
CoChat

The DOI matches its Crossref record; 27 of the 27 references it cites were found in a registry or an index.

Miscibility and Mechanical Properties of Blends of (l)-Lactide Copolymers with Atactic Poly(3-hydroxybutyrate)

Focarete, Maria Letizia, Scandola, Mariastella, Dobrzynski, Piotr, Kowalczuk, Marek · 2002 · Macromolecules

Abstract

Poly( l -lactide- co -glycolide) (PLLAGA) copolymers and poly( dl -lactide) (PDLLA) were synthesized using the low toxicity compound zirconium(IV) acetylacetonate. Blends with synthetic atactic poly(3-hydroxybutyrate) (a-PHB) were prepared in film form by solvent casting. The solid-state properties of the plain polymers and of the blends were investigated by thermogravimetric analysis coupled with mass spectrometry (TGA−MS), differential scanning calorimetry (DSC), wide-angle X-ray diffraction (WAXD) and stress−strain measurements. The a-PHB/PDLLA blends are miscible over the whole composition range. On the other hand, blends of a-PHB with PLLAGA copolymers containing 5 and 16 mol % of GA units show partial miscibility. The solubility limit of a-PHB in PLLAGA is around 20 wt % in both cases. In the blends, the a-PHB in excess to this value segregates as a pure phase. The mechanical properties of blend films of either PDLLA or PLLAGA containing up to 50 wt % of a-PHB can be modulated by changing blend composition. The tenacity progressively increases by the addition of a-PHB not only in the miscible amorphous a-PHB/PDLLA system but also in the partially miscible a-PHB/PLLAGA blends.

Overview

Integrity signals

Registry

Crossref · 10.1021/ma020940z

Cites

27 of 27 references verified0 citation errors · 0 not checkable

Statistics

Recomputing p-values needs the paper’s full text.

Verification

Claims the paper makes

This paper’s full text isn’t openly available, so its claims and self-check weren’t run. The registry and citation checks still apply.

Citations

Cites

Show all 27 references

Research works printed but not linked: 11

  1. Khon J., 1996, Biomaterial Science
  2. Seebach D., 1995, Biopolymers and -oligomers of (R)-3-Hydroxyalkanoic Acids−Contributions of Synthetic Organic Chemists
  3. Jedlinski Z., 1991, Macromolecules, 24, 352
  4. Kurcok P., 1992, Macromolecules, 25, 2020
  5. McNeill I. C., 1985, Polym. Degrad. Stab., 11, 285
  6. Kopinke F.-D., 1996, Polym. Degrad. Stab., 53, 342
  7. McNeill I. C., 1985, Polym. Degrad. Stab., 11, 326
  8. Grassie N., 1984, Polym. Degrad. Stab., 6, 61
  9. Grassie N., 1984, Polym. Degrad. Stab., 6, 134
  10. Fischer E. W., 1972, Kolloid Z. Z. Polym., 251, 990
  11. Wood L. A., 1958, J. Polym. Sci., 28, 330

Metadata

Authors
Focarete, M. L., Scandola, M., Dobrzynski, P., & Kowalczuk, M.
Affiliations
Institute of Organic Synthesis and Photoreactivity (IT)
Venue
Macromolecules
Published
2002-09-25
Volume
35
Issue
22
Pages
8472-8477
ISSN
  • 0024-9297 (ISSN-L)
  • 1520-5835
OpenAlex
W2083360677
Cited by
119
References
27
Citations by year
2025: 1 · 2024: 3 · 2023: 2 · 2022: 2 · 2021: 2 · 2019: 4 · 2018: 2 · 2017: 4 · 2016: 5 · 2015: 11 · 2014: 10 · 2013: 8 · 2012: 12
FWCI
1.93
Type
journal article
Language
en
Open access
closed
Locations
Macromolecules (publishedVersion)
Topics
  • Physical Sciences › Materials Science › Biomaterials › biodegradable polymer synthesis and properties
  • Physical Sciences › Materials Science › Polymers and Plastics › Polymer crystallization and properties
  • Physical Sciences › Materials Science › Materials Chemistry › Block Copolymer Self-Assembly
Keywords
polyhydroxybutyrate, poly(L-lactide-co-glycolide), poly(L-lactic acid), polymer blends, miscibility, phase separation, solubility limit, mechanical properties, tenacity, biodegradable polymers, polymer blend films

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.