Dissipative Particle Dynamics Studies on Microstructure of pH-Sensitive Micelles for Sustained Drug Delivery
The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.
Abstract
Dissipative particle dynamics simulations were performed to study the microstructures of doxorubicin (DOX) loaded/blank micelles self-assembled from cholesterol conjugated His 10 Arg 10 (HR20-Chol) at different pH conditions. DOX molecules can be efficiently encapsulated in the core of micelles. At pH > 6.0, these micelles have stronger DOX loading ability due to the hydrophobicity of histidine residues, as compared to that of pH < 6.0. With the decrease of pH from pH > 6.0 to pH < 6.0, the structure of micelles trends to be swelling from dense conformations. This structural transformation can facilitate the release of DOX from the core of micelles. All the simulation results are qualitatively consistent with the experimental results, demonstrating that the DPD method may provide a powerful tool in analysis and design of drug delivery systems.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Simulating microscopic hydrodynamic phenomena with dissipative particle dynamics
Hoogerbrugge, P. J., & Koelman, J. M. V. A. (1992) · Europhysics Letters (EPL) · doi:10.1209/0295-5075/19/3/001 · Cited by 3,811
Thermo- and pH-responsive polymers in drug delivery☆
SCHMALJOHANN, D. (2006) · Advanced Drug Delivery Reviews · doi:10.1016/j.addr.2006.09.020 · Cited by 3,023
Patel, S., Lavasanifar, A., & Choi, P. (2008) · Biomacromolecules · doi:10.1021/bm800320z · Cited by 92
Cited by
pH-Sensitive nano-systems for drug delivery in cancer therapy
Liu, J., Huang, Y., Kumar, A., Tan, A., Jin, S., Mozhi, A., & Liang, X.-J. (2014) · Biotechnology Advances · doi:10.1016/j.biotechadv.2013.11.009 · Cited by 1,121
Moradi Kashkooli, F., Soltani, M., & Souri, M. (2020) · Journal of Controlled Release · doi:10.1016/j.jconrel.2020.08.012 · Cited by 514
Switchable pH-Responsive Polymeric Membranes Prepared via Block Copolymer Micelle Assembly
Nunes, S. P., Behzad, A. R., Hooghan, B., Sougrat, R., Karunakaran, M., Pradeep, N., Vainio, U., & Peinemann, K.-V. (2011) · ACS Nano · doi:10.1021/nn200484v · Cited by 295
Luo, Z., & Jiang, J. (2012) · Journal of Controlled Release · doi:10.1016/j.jconrel.2012.06.027 · Cited by 193
Nexus between in silico and in vivo models to enhance clinical translation of nanomedicine
Moradi Kashkooli, F., Soltani, M., Souri, M., Meaney, C., & Kohandel, M. (2021) · Nano Today · doi:10.1016/j.nantod.2020.101057 · Cited by 120
Computational amphiphilic materials for drug delivery
Thota, N., & Jiang, J. (2015) · Frontiers in Materials · doi:10.3389/fmats.2015.00064 · Cited by 38
“Consistent with FAMD simulation, water molecules were excluded from the hydrophobic core (Lee et al., 2012a).”
BackgroundResultInfluentialHan, Y., Liu, S., Mao, H., Tian, L., & Ning, W. (2016) · Polymers · doi:10.3390/polym8110367 · Cited by 17
Metadata
- Authors
- Guo, X. D., Zhang, L. J., Wu, Z. M., & Qian, Y.
- Venue
- Macromolecules
- Publisher
- American Chemical Society (ACS)
- Published
- 2010-07-30
- Volume
- 43
- Issue
- 18
- Pages
- 7839-7844
- ISSN
- 0024-9297 (ISSN-L)
- 1520-5835
- OpenAlex
- W1991382157
- Cited by
- 122
- References
- 3
- FWCI
- 2.69
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.