The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Multiple Micellization and Dissociation Transitions of Thermo- and Light-Sensitive Poly(ethylene oxide)-b-poly(ethoxytri(ethylene glycol) acrylate-co-o-nitrobenzyl acrylate) in Water
Abstract
This article reports on the synthesis of thermo- and light-sensitive hydrophilic block copolymers, poly(ethylene oxide)- b -poly(ethoxytri(ethylene glycol) acrylate- co - o -nitrobenzyl acrylate), and the study of their micellization/dissociation transitions in water in response to temperature changes and UV irradiation. The block copolymers with controlled molecular weights and narrow polydispersities were synthesized by atom transfer radical polymerization of a mixture of ethoxytri(ethylene glycol) acrylate and o -nitrobenzyl acrylate with a molar ratio of 100:10 from a PEO macroinitiator. Dynamic light scattering and fluorescence spectroscopy studies showed that these copolymers were molecularly dissolved in water at lower temperatures and self-assembled into micelles with the thermosensitive block associating into the core and the PEO block forming the corona when the temperature was above the lower critical solution temperature (LCST) of the thermosensitive block. Upon UV irradiation, the o -nitrobenzyl group was cleaved and the LCST of the thermosensitive block was increased, causing the dissociation of micelles into unimers and the release of encapsulated fluorescent dye Nile Red into water. Further increasing the temperature induced the formation of micelles again and the re-encapsulation of Nile Red. The thermo-induced formation and dissociation of micelles were reversible.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Synthetic Micelle Sensitive to IR Light via a Two-Photon Process
Goodwin, A. P., Mynar, J. L., Ma, Y., Fleming, G. R., & Fréchet, J. M. J. (2005) · Journal of the American Chemical Society · doi:10.1021/ja0523035 · Cited by 352
Cited by
Dual and multi-stimuli responsive polymeric nanoparticles for programmed site-specific drug delivery
Cheng, R., Meng, F., Deng, C., Klok, H.-A., & Zhong, Z. (2013) · Biomaterials · doi:10.1016/j.biomaterials.2013.01.084 · Cited by 1,354
Motornov, M., Roiter, Y., Tokarev, I., & Minko, S. (2010) · Progress in Polymer Science · doi:10.1016/j.progpolymsci.2009.10.004 · Cited by 773
Multi-Stimuli Sensitive Amphiphilic Block Copolymer Assemblies
Klaikherd, A., Nagamani, C., & Thayumanavan, S. (2009) · Journal of the American Chemical Society · doi:10.1021/ja809475a · Cited by 594
3D Printed Photoresponsive Devices Based on Shape Memory Composites
Yang, H., Leow, W. R., Wang, T., Wang, J., Yu, J., He, K., Qi, D., Wan, C., & Chen, X. (2017) · Advanced Materials · doi:10.1002/adma.201701627 · Cited by 483
Stimuli-Responsive Polymers and Their Applications in Nanomedicine
Cabane, E., Zhang, X., Langowska, K., Palivan, C. G., & Meier, W. (2012) · Biointerphases · doi:10.1007/s13758-011-0009-3 · Cited by 468
Metadata
- Authors
- Jiang, X., Lavender, C. A., Woodcock, J. W., & Zhao, B.
- Venue
- Macromolecules
- Publisher
- American Chemical Society (ACS)
- Published
- 2008-03-08
- Volume
- 41
- Issue
- 7
- Pages
- 2632-2643
- ISSN
- 0024-9297 (ISSN-L)
- 1520-5835
- OpenAlex
- W2066960931
- Cited by
- 207
- References
- 1
- FWCI
- 10.07
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.