The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Sugar-Installed Polymer Micelles: Synthesis and Micellization of Poly(ethylene glycol)−Poly(d,l-lactide) Block Copolymers Having Sugar Groups at the PEG Chain End
Abstract
A poly(ethylene glycol)−poly( d, l -lactide) block copolymer (PEG−PLA) having a site specifically protected-sugar group at the PEG chain end was synthesized through a successive ring-opening polymerization of ethylene oxide and d, l -lactide using a metalated protected sugar as an initiator. Removal of protective groups from the sugar residue in the block copolymer was quantitatively carried out using 80% trifluoroacetic acid at room temperature, yielding a block copolymer having a glucose or galactose residue at the chain end in a regioselective manner. Polymer micelles having sugar residues on the surface were then prepared by dialyzing an N, N -dimethylacetamide solution of the sugar-bearing PEG−PLA block copolymer against water. Dynamic light-scattering measurement of the polymer micelle solution revealed that the scaled characteristics line width had essentially no angular dependence, consistent with the spherical geometry of the polymer micelle. The diameter and polydispersity index of the polymer micelle, determined by a cumulant method, were approximately 40 nm and less than 0.1, respectively. Further, a galactose-bearing PEG−PLA micelle was confirmed to selectively attach to RCA-1 lectin, which is known to recognize β- d -galactose residues. These polymer micelles having sugar groups regioselectively on their exterior are expected to have wide utility in the field of drug delivery as glyco-receptor-directed carrier systems.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Kwon, G., Suwa, S., Yokoyama, M., Okano, T., Sakurai, Y., & Kataoka, K. (1994) · Journal of Controlled Release · doi:10.1016/0168-3659(94)90118-x · Cited by 409
Self-citationKabanov, A. V., Chekhonin, V. P., Alakhov, V. Y., Batrakova, E. V., Lebedev, A. S., Melik-Nubarov, N. S., Arzhakov, S. A., Levashov, A. V., Morozov, G. V., Severin, E. S., et al. (1989) · FEBS Letters · doi:10.1016/0014-5793(89)81689-8 · Cited by 296
Cited by
Block copolymer micelles for drug delivery: design, characterization and biological significance
Kataoka, K., Harada, A., & Nagasaki, Y. (2001) · Advanced Drug Delivery Reviews · doi:10.1016/s0169-409x(00)00124-1 · Cited by 3,506
Self-citationRecent Developments in Ring Opening Polymerization of Lactones for Biomedical Applications
Albertsson, A.-C., & Varma, I. K. (2003) · Biomacromolecules · doi:10.1021/bm034247a · Cited by 1,582
Block copolymer micelles: preparation, characterization and application in drug delivery
Gaucher, G., Dufresne, M.-H., Sant, V. P., Kang, N., Maysinger, D., & Leroux, J.-C. (2005) · Journal of Controlled Release · doi:10.1016/j.jconrel.2005.09.034 · Cited by 1,498
Block copolymer micelles in nanomedicine applications
Cabral, H., Miyata, K., Osada, K., & Kataoka, K. (2018) · Chemical Reviews · doi:10.1021/acs.chemrev.8b00199 · Cited by 1,309
Self-citationNicolas, J., Mura, S., Brambilla, D., Mackiewicz, N., & Couvreur, P. (2013) · Chem. Soc. Rev. · doi:10.1039/c2cs35265f · Cited by 1,270
Metadata
- Authors
- Yasugi, K., Nakamura, T., Nagasaki, Y., Kato, M., & Kataoka, K.
- Venue
- Macromolecules
- Publisher
- American Chemical Society (ACS)
- Published
- 1999-11-01
- Volume
- 32
- Issue
- 24
- Pages
- 8024-8032
- ISSN
- 0024-9297 (ISSN-L)
- 1520-5835
- OpenAlex
- W1989605629
- Cited by
- 176
- References
- 2
- FWCI
- 4.61
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.