CoChat

Molecular Engineering of Silk-Elastinlike Polymers for Matrix-Mediated Gene Delivery: Biosynthesis and Characterization

Haider, Mohamed, Leung, Vivian, Ferrari, Franco, Crissman, John, Powell, James, Cappello, Joseph, Ghandehari, Hamidreza · 2005 · Molecular Pharmaceutics
Cited by 104

The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.

Abstract

The unique advantage of genetic engineering techniques for the design and development of polymers for controlled gene delivery lies in exquisite control over polymer structure. In this article we report the biosynthesis and characterization of a series of new silk-elastinlike protein polymers (SELPs), namely, SELP415K, with larger elastin blocks per monomer unit than SELP47K previously studied for matrix-mediated gene delivery. A new cloning strategy was used, where a block of eight elastin units (8E) was integrated into the existing DNA sequence of SELP47K monomer genes using appropriate restriction endonuclease recognition sites. Following random multimerization, multimer gene segments of desired size were selected, expressed, and purified on Ni-agarose columns. The molecular weight and sequence composition of the purified SELPs were determined by MALDI-TOF and amino acid analysis, respectively. The influence of structural changes on the rheological properties of the polymers was investigated. In addition, hydrogel disks were prepared from 47K and 415K-8mer polymer solutions, and the effects of cure time and environmental conditions on the hydrogel equilibrium swelling ratio as a function of polymer composition were studied. DNA sequencing and agarose gel electrophoresis confirmed the successful cloning of the monomer gene segment of SELP415K consisting of 312 bp. Random concatemerization of SELP415K monomer gene segments resulted in a library of SELP415K multimer sequences of 6, 8, and 10 repeats respectively, each yielding a polymer with exact molecular weight and sequence. Rheometric measurements showed that both complex shear modulus (G*) and gelation point were influenced by polymer composition. Equilibrium swelling studies on hydrogel disks prepared from 47K and 415K-8mer polymer solutions showed that changes in polymer composition resulted in different gelation patterns and increased sensitivity toward changes in temperature and ionic strength but not pH. Together these results demonstrate the potential of recombinant techniques in engineering polymers with defined structures which allows the study of the structural parameters affecting matrix-mediated delivery of genes and bioactive agents.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1021/mp049906s

Cites

3 of 3 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Cited by

See all 104

Metadata

Authors
Haider, M., Leung, V., Ferrari, F., Crissman, J., Powell, J., Cappello, J., & Ghandehari, H.
Venue
Molecular Pharmaceutics
Published
2005-02-26
Volume
2
Issue
2
Pages
139-150
ISSN
  • 1543-8384 (ISSN-L)
  • 1543-8392
OpenAlex
W2091810337
Cited by
104
References
3
FWCI
4.24
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.