Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 771

The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.

Electronic Detection of Specific Protein Binding Using Nanotube FET Devices

Star, Alexander, Gabriel, Jean-Christophe P., Bradley, Keith, Grüner, George·2003·Nano Letters

Abstract

We have used nanoscale field effect transistor devices with carbon nanotubes as the conducting channel to detect protein binding. A PEI/PEG polymer coating layer has been employed to avoid nonspecific binding, with attachment of biotin to the layer for specific molecular recognition. Biotin-streptavidin binding has been detected by changes in the device characteristic. Nonspecific binding was observed in devices without the polymer coating, while no binding was found for polymer-coated but not biotinylated devices. Streptavidin, in which the biotin-binding sites were blocked by reaction with excess biotin, produced essentially no change in device characteristic of the biotinylated polymer-coated devices.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1021/nl0340172

Cites

1 of 1 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 1 references

Cited by

See all 771

Metadata

Authors
Star, A., Gabriel, J.-C. P., Bradley, K., & Grüner, G.
Venue
Nano Letters
Published
2003-03-05
Volume
3
Issue
4
Pages
459-463
ISSN
  • 1530-6984 (ISSN-L)
  • 1530-6992
OpenAlex
W2135331413
Cited by
771
References
1
FWCI
38.55
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Electronic Detection of Specific Protein Binding Using Nanotube FET Devices. https://app.cochat.ai/papers/10.1021/nl0340172
The paper
Star, A., Gabriel, J.-C. P., Bradley, K., & Grüner, G. (2003). Electronic Detection of Specific Protein Binding Using Nanotube FET Devices. Nano Letters. https://doi.org/10.1021/nl0340172

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.