The DOI matches its Crossref record.
A Precisely Controlled DNA Biped Walking Device
Abstract
We present an experimental realization of a molecular walking motor built from DNA. The device consists of a biped and a well-defined track where it walks. Input DNA strands act as a convenient interface to allow precise control of the biped walking forward or backward. Psoralen molecules are attached to the ends of the feet in synthesis. When irradiated, the psoralen molecules cross-link strands covalently, allowing unambiguous determination of the state of the walker.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Seeman, N. C., & Sleiman, H. F. (2017) · Nature Reviews Materials · doi:10.1038/natrevmats.2017.68 · Cited by 1,875
Self-citationDynamic DNA nanotechnology using strand-displacement reactions
Zhang, D. Y., & Seelig, G. (2011) · Nature Chemistry · doi:10.1038/nchem.957 · Cited by 1,785
Programmable materials and the nature of the DNA bond
Jones, M. R., Seeman, N. C., & Mirkin, C. A. (2015) · Science · doi:10.1126/science.1260901 · Cited by 1,347
Self-citationSeeman, N. C. (2010) · Annual Review of Biochemistry · doi:10.1146/annurev-biochem-060308-102244 · Cited by 992
Self-citationPrinciples and Applications of Nucleic Acid Strand Displacement Reactions
Simmel, F. C., Yurke, B., & Singh, H. R. (2019) · Chemical Reviews · doi:10.1021/acs.chemrev.8b00580 · Cited by 792
Metadata
- Authors
- Sherman, W. B., & Seeman, N. C.
- Venue
- Nano Letters
- Publisher
- American Chemical Society (ACS)
- Published
- 2004-04-22
- Volume
- 4
- Issue
- 7
- Pages
- 1203-1207
- ISSN
- 1530-6984 (ISSN-L)
- 1530-6992
- OpenAlex
- W2027838042
- Cited by
- 573
- References
- 0
- FWCI
- 13.34
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: A Precisely Controlled DNA Biped Walking Device. https://app.cochat.ai/papers/10.1021/nl049527q
- The paper
- Sherman, W. B., & Seeman, N. C. (2004). A Precisely Controlled DNA Biped Walking Device. Nano Letters. https://doi.org/10.1021/nl049527q
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.