The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Screening-Limited Response of NanoBiosensors
Open accessAbstract
Despite tremendous potential of highly sensitive electronic detection of biomolecules by nanoscale biosensors for genomics and proteomic applications, many aspects of experimentally observed sensor response (S) are difficult to understand within isolated theoretical frameworks of kinetic response or electrolyte screening. In this paper, we combine analytic solutions of Poisson-Boltzmann and diffusion-capture equations to show that the electrostatic screening within an ionic environment limits the response of nanobiosensor such that S(t) approximately c1(ln(rho0) - ln(I0)/2 + ln(t)/ D F + c2[pH]) + c3 where c i are geometry-dependent constants, rho0 is the concentration of target molecules, I0 the salt concentration, and D F the fractal dimension of sensor surface. Our analysis provides a coherent theoretical interpretation of a wide variety of puzzling experimental data that have so far defied intuitive explanation.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Label-free immunodetection with CMOS-compatible semiconducting nanowires
Stern, E., Klemic, J. F., Routenberg, D. A., Wyrembak, P. N., Turner-Evans, D. B., Hamilton, A. D., LaVan, D. A., Fahmy, T. M., & Reed, M. A. (2007) · Nature · doi:10.1038/nature05498 · Cited by 1,352
Cited by
Subthreshold Regime has the Optimal Sensitivity for Nanowire FET Biosensors
Gao, X. P. A., Zheng, G., & Lieber, C. M. (2010) · Nano Letters · doi:10.1021/nl9034219 · Cited by 571
Nernst Limit in Dual-Gated Si-Nanowire FET Sensors
Knopfmacher, O., Tarasov, A., Fu, W., Wipf, M., Niesen, B., Calame, M., & Schönenberger, C. (2010) · Nano Letters · doi:10.1021/nl100892y · Cited by 353
Two-dimensional Layered MoS2 Biosensors Enable Highly Sensitive Detection of Biomolecules
Lee, J., Dak, P., Lee, Y., Park, H., Choi, W., Alam, M. A., & Kim, S. (2014) · Scientific Reports · doi:10.1038/srep07352 · Cited by 318
Self-citationGraphene nanoelectronic heterodyne sensor for rapid and sensitive vapour detection
Kulkarni, G. S., Reddy, K., Zhong, Z., & Fan, X. (2014) · Nature Communications · doi:10.1038/ncomms5376 · Cited by 189
Effect of Nanowire Number, Diameter, and Doping Density on Nano-FET Biosensor Sensitivity
Li, J., Zhang, Y., To, S., You, L., & Sun, Y. (2011) · ACS Nano · doi:10.1021/nn202182p · Cited by 138
Metadata
- Authors
- Nair, P. R., & Alam, M. A.
- Venue
- Nano Letters
- Publisher
- American Chemical Society (ACS)
- Published
- 2008-04-03
- Volume
- 8
- Issue
- 5
- Pages
- 1281-1285
- ISSN
- 1530-6984 (ISSN-L)
- 1530-6992
- OpenAlex
- W2094693115
- Cited by
- 227
- References
- 1
- FWCI
- 7.44
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.