The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Stretchable Magnetoelectronics
Open accessAbstract
We fabricated [Co/Cu] multilayers revealing a giant magnetoresistance (GMR) effect on free-standing elastic poly(dimethylsiloxane) (PDMS) membranes. The GMR performance of [Co/Cu] multilayers on rigid silicon and on free-standing PDMS is similar and does not change with tensile deformations up to 4.5%. Mechanical deformations imposed on the sensor are totally reversible, due to the elasticity of the PDMS membranes. This remarkable performance upon stretching relies on a wrinkling of GMR layers on top of the PDMS membrane.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Kim, R.-H., Kim, D.-H., Xiao, J., Kim, B. H., Park, S.-I., Panilaitis, B., Ghaffari, R., Yao, J., Li, M., Liu, Z., et al. (2010) · Nature Materials · doi:10.1038/nmat2879 · Cited by 637
Cited by
Skin-inspired highly stretchable and conformable matrix networks for multifunctional sensing
Hua, Q., Sun, J., Liu, H., Bao, R., Yu, R., Zhai, J., Pan, C., & Wang, Z. L. (2018) · Nature Communications · doi:10.1038/s41467-017-02685-9 · Cited by 1,413
Three-dimensional nanomagnetism
Fernández-Pacheco, A., Streubel, R., Fruchart, O., Hertel, R., Fischer, P., & Cowburn, R. P. (2017) · Nature Communications · doi:10.1038/ncomms15756 · Cited by 592
Magnetism in curved geometries
Streubel, R., Fischer, P., Kronast, F., Kravchuk, V. P., Sheka, D. D., Gaididei, Y., Schmidt, O. G., & Makarov, D. (2016) · Journal of Physics D: Applied Physics · doi:10.1088/0022-3727/49/36/363001 · Cited by 371
Self-citationJamali, M., Lee, J. S., Jeong, J. S., Mahfouzi, F., Lv, Y., Zhao, Z., Nikolić, B. K., Mkhoyan, K. A., Samarth, N., & Wang, J.-P. (2015) · Nano Letters · doi:10.1021/acs.nanolett.5b03274 · Cited by 314
Mechanically‐Guided Structural Designs in Stretchable Inorganic Electronics
Xue, Z., Song, H., Rogers, J. A., Zhang, Y., & Huang, Y. (2020) · Advanced Materials · doi:10.1002/adma.201902254 · Cited by 314
Magnetoresistive Sensor Development Roadmap (Non-Recording Applications)
Zheng, C., Zhu, K., Cardoso de Freitas, S., Chang, J.-Y., Davies, J. E., Eames, P., Freitas, P. P., Kazakova, O., Kim, C., Leung, C.-W., et al. (2019) · IEEE Transactions on Magnetics · doi:10.1109/tmag.2019.2896036 · Cited by 268
Wearable Magnetic Field Sensors for Flexible Electronics
Melzer, M., Mönch, J. I., Makarov, D., Zabila, Y., Cañón Bermúdez, G. S., Karnaushenko, D., Baunack, S., Bahr, F., Yan, C., Kaltenbrunner, M., et al. (2015) · Advanced Materials · doi:10.1002/adma.201405027 · Cited by 265
Self-citationUltrasensitive self-powered pressure sensing system
Luo, J., Fan, F. R., Zhou, T., Tang, W., Xue, F., & Wang, Z. L. (2015) · Extreme Mechanics Letters · doi:10.1016/j.eml.2015.01.008 · Cited by 87
Flexible MgO Barrier Magnetic Tunnel Junctions
Loong, L. M., Lee, W., Qiu, X., Yang, P., Kawai, H., Saeys, M., Ahn, J., & Yang, H. (2016) · Advanced Materials · doi:10.1002/adma.201600062 · Cited by 82
Metadata
- Authors
- Melzer, M., Makarov, D., Calvimontes, A., Karnaushenko, D., Baunack, S., Kaltofen, R., Mei, Y., & Schmidt, O. G.
- Venue
- Nano Letters
- Publisher
- American Chemical Society (ACS)
- Published
- 2011-05-10
- Volume
- 11
- Issue
- 6
- Pages
- 2522-2526
- ISSN
- 1530-6984 (ISSN-L)
- 1530-6992
- OpenAlex
- W4253864062
- Cited by
- 167
- References
- 1
- FWCI
- 5.39
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.