The DOI matches its Crossref record.
Knitted Fabrics Made from Highly Conductive Stretchable Fibers
Abstract
We report knitted fabrics made from highly conductive stretchable fibers. The maximum initial conductivity of fibers synthesized by wet spinning was 17460 S cm(-1) with a rupture tensile strain of 50%. The maximum strain could be increased to 490% by decreasing the conductivity to 236 S cm(-1). The knitted fabric was mechanically and electrically reversible up to 100% tensile strain when coated by poly(dimethylsiloxane). The normalized resistance of the poly(dimethylsiloxane)-coated fabric decreased to 0.65 at 100% strain.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Technology Roadmap for Flexible Sensors
Luo, Y., Abidian, M. R., Ahn, J.-H., Akinwande, D., Andrews, A. M., Antonietti, M., Bao, Z., Berggren, M., Berkey, C. A., Bettinger, C. J., et al. (2023) · ACS Nano · doi:10.1021/acsnano.2c12606 · Cited by 1,383
Nature-Inspired Structural Materials for Flexible Electronic Devices
Liu, Y., He, K., Chen, G., Leow, W. R., & Chen, X. (2017) · Chemical Reviews · doi:10.1021/acs.chemrev.7b00291 · Cited by 798
Materials and Structures toward Soft Electronics
Wang, C., Wang, C., Huang, Z., & Xu, S. (2018) · Advanced Materials · doi:10.1002/adma.201801368 · Cited by 662
Hao, P., Zhao, Z., Leng, Y., Tian, J., Sang, Y., Boughton, R. I., Wong, C. P., Liu, H., & Yang, B. (2015) · Nano Energy · doi:10.1016/j.nanoen.2015.02.035 · Cited by 644
Kim, K. K., Hong, S., Cho, H. M., Lee, J., Suh, Y. D., Ham, J., & Ko, S. H. (2015) · Nano Letters · doi:10.1021/acs.nanolett.5b01505 · Cited by 626
Self-citationAg Nanowire Reinforced Highly Stretchable Conductive Fibers for Wearable Electronics
Lee, S., Shin, S., Lee, S., Seo, J., Lee, J., Son, S., Cho, H. J., Algadi, H., Al‐Sayari, S., Kim, D. E., et al. (2015) · Advanced Functional Materials · doi:10.1002/adfm.201500628 · Cited by 605
Self-citationChoi, S., Han, S. I., Kim, D., Hyeon, T., & Kim, D.-H. (2019) · Chemical Society Reviews · doi:10.1039/c8cs00706c · Cited by 591
Choi, S., Park, J., Hyun, W., Kim, J., Kim, J., Lee, Y. B., Song, C., Hwang, H. J., Kim, J. H., Hyeon, T., et al. (2015) · ACS Nano · doi:10.1021/acsnano.5b02790 · Cited by 568
Liang, J., Tong, K., & Pei, Q. (2016) · Advanced Materials · doi:10.1002/adma.201600772 · Cited by 535
One‐Dimensional Nanomaterials for Soft Electronics
Gong, S., & Cheng, W. (2017) · Advanced Electronic Materials · doi:10.1002/aelm.201600314 · Cited by 361
Sun, J., Huang, Y., Fu, C., Wang, Z., Huang, Y., Zhu, M., Zhi, C., & Hu, H. (2016) · Nano Energy · doi:10.1016/j.nanoen.2016.07.008 · Cited by 331
Knitted Strain Sensor Textiles of Highly Conductive All-Polymeric Fibers
Seyedin, S., Razal, J. M., Innis, P. C., Jeiranikhameneh, A., Beirne, S., & Wallace, G. G. (2015) · ACS Applied Materials & Interfaces · doi:10.1021/acsami.5b04892 · Cited by 331
Zhang, Q., Liu, X., Duan, L., & Gao, G. (2019) · Chemical Engineering Journal · doi:10.1016/j.cej.2019.02.014 · Cited by 321
Metadata
- Authors
- Ma, R., Lee, J., Choi, D., Moon, H., & Baik, S.
- Venue
- Nano Letters
- Publisher
- American Chemical Society (ACS)
- Published
- 2014-03-24
- Volume
- 14
- Issue
- 4
- Pages
- 1944-1951
- ISSN
- 1530-6984 (ISSN-L)
- 1530-6992
- OpenAlex
- W2331547947
- Cited by
- 164
- References
- 0
- FWCI
- 8.94
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.