The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Dynamic Inversion Enables External Magnets To Concentrate Ferromagnetic Rods to a Central Target
Abstract
The ability to use magnets external to the body to focus therapy to deep tissue targets has remained an elusive goal in magnetic drug targeting. Researchers have hitherto been able to manipulate magnetic nanotherapeutics in vivo with nearby magnets but have remained unable to focus these therapies to targets deep within the body using magnets external to the body. One of the factors that has made focusing of therapy to central targets between magnets challenging is Samuel Earnshaw’s theorem as applied to Maxwell’s equations. These mathematical formulations imply that external static magnets cannot create a stable potential energy well between them. We posited that fast magnetic pulses could act on ferromagnetic rods before they could realign with the magnetic field. Mathematically, this is equivalent to reversing the sign of the potential energy term in Earnshaw’s theorem, thus enabling a quasi-static stable trap between magnets. With in vitro experiments, we demonstrated that quick, shaped magnetic pulses can be successfully used to create inward pointing magnetic forces that, on average, enable external magnets to concentrate ferromagnetic rods to a central location.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Polyak, B., Fishbein, I., Chorny, M., Alferiev, I., Williams, D., Yellen, B., Friedman, G., & Levy, R. J. (2008) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0708338105 · Cited by 257
Wilson, M. W., Kerlan, R. K., Fidelman, N. A., Venook, A. P., LaBerge, J. M., Koda, J., & Gordon, R. L. (2004) · Radiology · doi:10.1148/radiol.2301021493 · Cited by 190
Research works printed but not linked: 38
- Strebhardt, 2008, Nat. Rev. Cancer, 8, 473, 10.1038/nrc2394 · DOI · Paper page
- Lubbe, 1996, Cancer Res., 56, 4686
- Pouponneau, 2011, Biomaterials, 32, 3481, 10.1016/j.biomaterials.2010.12.059 · DOI · Paper page
- Krukemeyer, 2012, J. Surg Res., 175, 35, 10.1016/j.jss.2011.01.060 · DOI
- Liu, 2010, Proc. Natl. Acad. Sci. U.S.A., 107, 15205, 10.1073/pnas.1003388107 · DOI · Paper page
- Raut, 2010, Nanotechnology, 21, 395102, 10.1088/0957-4484/21/39/395102 · DOI
- Koda, 2002, Eur. J. Cancer, 38, S18
- McBain, 2008, Int. J. Nanomed., 3, 169
- Lemke, 2004, Eur. Radiol., 14, 1949, 10.1007/s00330-004-2445-7 · DOI
- Lemke, 1996, Radiology, 201, 1421
- Pouponneau, 2009, Biomaterials, 30, 6327, 10.1016/j.biomaterials.2009.08.005 · DOI
- Forbes, 2008, IEEE Trans. Biomed. Eng., 55, 643, 10.1109/TBME.2007.899347 · DOI
- Fernández-Pacheco, 2007, J. Magn. Magn. Mater., 311, 318, 10.1016/j.jmmm.2006.11.192 · DOI
- Yanai, 2012, Cell Transplant., 21, 1137, 10.3727/096368911X627435 · DOI
- Lübbe, 2001, J. Surg. Res., 95, 200, 10.1006/jsre.2000.6030 · DOI · Paper page
- Pislaru, 2006, J. Am. Coll. Cardiol., 48, 1839, 10.1016/j.jacc.2006.06.069 · DOI
- Dobson, 2006, Nanomedicine, 1, 31, 10.2217/17435889.1.1.31 · DOI · Paper page
- Shapiro, 2009, J. Magn. Magn. Mater., 321, 1594, 10.1016/j.jmmm.2009.02.094 · DOI
- Hayden, 2006, J. Phys.: Condens. Matter, 18, S2877
- Cao, 2011, J. Magn. Magn. Mater., 323, 1919, 10.1016/j.jmmm.2010.11.058 · DOI
- Schuerle, 2013, IEEE Trans. Magn., 49, 321, 10.1109/TMAG.2012.2224693 · doi:10.1109/tmag.2012.2224693
- Brandt, 1989, Science, 243, 349, 10.1126/science.243.4889.349 · DOI
- Geim, 1999, Nature, 400, 323, 10.1038/22444 · doi:10.1038/22444
- Earnshaw, 1842, Trans. Cambridge Philos. Soc., 7, 97
- Nacev, 2012, IEEE Control Syst., 32, 32, 10.1109/MCS.2012.2189052 · DOI
- Weinberg, 2012, Med. Phys., 39, 2578, 10.1118/1.3702775 · DOI
- Pankhurst, 2003, J. Phys. D: Appl. Phys., 36, R167, 10.1088/0022-3727/36/13/201 · DOI · Paper page
- Feynman, 1964, The Feynman Lectures on Physics, 10.1063/1.3051743 · DOI · Paper page
- Zborowski, 1997, Scientific and Clinical Applications of Magnetic Carriers SE-15, 205, 10.1007/978-1-4757-6482-6_15 · DOI
- Salem, 2003, Nat. Mater., 2, 668, 10.1038/nmat974 · DOI · Paper page
- Babincova, 2001, Zeit. Naturforsch. C-a: J. Biosci., 56, 909, 10.1515/znc-2001-9-1039 · doi:10.1515/znc-2001-9-1039
- Polyak, 2009, Expert Opin. Drug Delivery, 6, 53, 10.1517/17425240802662795 · DOI · Paper page
- Nacev, 2010, Nanomed. London Engl., 5, 1459, 10.2217/nnm.10.104 · DOI
- Gleich, 2005, Nature, 435, 1214, 10.1038/nature03808 · DOI · Paper page
- Pankhurst, 2009, J. Phys. D: Appl. Phys., 42, 224001, 10.1088/0022-3727/42/22/224001 · DOI · Paper page
- Blums, 1997, Magnetic Fluids
- Metzger, 2000, IEEE Trans. Magn., 36, 30, 10.1109/20.824421 · DOI · Paper page
- Frka-Petesic, 2011, J. Magn. Magn. Mater., 323, 1309, 10.1016/j.jmmm.2010.11.036 · doi:10.1016/j.jmmm.2010.11.036
Cited by
Ulbrich, K., Holá, K., Šubr, V., Bakandritsos, A., Tuček, J., & Zbořil, R. (2016) · Chemical Reviews · doi:10.1021/acs.chemrev.5b00589 · Cited by 1,730
Diverse Applications of Nanomedicine
Pelaz, B., Alexiou, C., Alvarez-Puebla, R. A., Alves, F., Andrews, A. M., Ashraf, S., Balogh, L. P., Ballerini, L., Bestetti, A., Brendel, C., et al. (2017) · ACS Nano · doi:10.1021/acsnano.6b06040 · Cited by 1,350
Magnetic nanoparticles in nanomedicine: a review of recent advances
Wu, K., Su, D., Liu, J., Saha, R., & Wang, J.-P. (2019) · Nanotechnology · doi:10.1088/1361-6528/ab4241 · Cited by 509
Magnetic nanoparticle-based drug delivery for cancer therapy
Tietze, R., Zaloga, J., Unterweger, H., Lyer, S., Friedrich, R. P., Janko, C., Pöttler, M., Dürr, S., & Alexiou, C. (2015) · Biochemical and Biophysical Research Communications · doi:10.1016/j.bbrc.2015.08.022 · Cited by 425
A review of magnet systems for targeted drug delivery
Liu, Y.-L., Chen, D., Shang, P., & Yin, D.-C. (2019) · Journal of Controlled Release · doi:10.1016/j.jconrel.2019.03.031 · Cited by 298
Metadata
- Authors
- Nacev, A., Weinberg, I. N., Stepanov, P. Y., Kupfer, S., Mair, L. O., Urdaneta, M. G., Shimoji, M., Fricke, S. T., & Shapiro, B.
- Venue
- Nano Letters
- Publisher
- American Chemical Society (ACS)
- Published
- 2014-12-02
- Volume
- 15
- Issue
- 1
- Pages
- 359-364
- ISSN
- 1530-6984
- 1530-6992
- Cited by
- 74
- References
- 2
- Language
- en
- Funders
- National Cancer Institute (1R21CA140068-01, 1R43CA174280)
- National Institute on Deafness and Other Communication Disorders (1R41DC013534-01A1)
- National Institute of Neurological Disorders and Stroke (5R42NS073289)
- Division of Civil, Mechanical and Manufacturing Innovation (1261938)
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.