Mesoscopic Size Effects on the Thermal Conductance of Silicon Nanowire
The DOI matches its Crossref record; 4 of the 4 references it cites were found in a registry or an index.
Abstract
We report the measurement of thermal conductance of silicon nanowires at low temperature. It is demonstrated that the roughness at the nanometer scale plays a crucial role for the phonon transport in low-dimensional samples. To this end, using e-beam lithography, nanowires of size 200 nm by 100 nm and 10 microm long have been nanofabricated. Their thermal properties have been measured using the 3 omega method between 0.3 and 6 K. The change in the temperature behavior of the thermal conductance (quadratic temperature dependence of K(T)) is a signature of an intermediate regime lying between the classical Casimir regime and the quantum regime. The Casimir-Ziman model is used to show that this specific behavior originates in mesoscopic samples where the dominant phonon wavelength becomes commensurate to the characteristic length of the roughness of the nanowire surfaces.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Enhanced thermoelectric performance of rough silicon nanowires
Hochbaum, A. I., Chen, R., Delgado, R. D., Liang, W., Garnett, E. C., Najarian, M., Majumdar, A., & Yang, P. (2008) · Nature · doi:10.1038/nature06381 · Cited by 4,109
Thermal conductivity measurement from 30 to 750 K: the 3ω method
Cahill, D. G. (1990) · Review of Scientific Instruments · doi:10.1063/1.1141498 · Cited by 1,928
Shi, L., Li, D., Yu, C., Jang, W., Kim, D., Yao, Z., Kim, P., & Majumdar, A. (2003) · Journal of Heat Transfer · doi:10.1115/1.1597619 · Cited by 733
3 omega method for specific heat and thermal conductivity measurements
Lu, L., Yi, W., & Zhang, D. L. (2002) · arXiv · doi:10.48550/arxiv.quant-ph/0202038 · Cited by 447
Cited by
Nanoscale thermal transport. II. 2003–2012
Cahill, D. G., Braun, P. V., Chen, G., Clarke, D. R., Fan, S., Goodson, K. E., Keblinski, P., King, W. P., Mahan, G. D., Majumdar, A., et al. (2014) · Applied Physics Reviews · doi:10.1063/1.4832615 · Cited by 1,763
Fundamental aspects of steady-state conversion of heat to work at the nanoscale
Benenti, G., Casati, G., Saito, K., & Whitney, R. S. (2017) · Physics Reports · doi:10.1016/j.physrep.2017.05.008 · Cited by 664
Advances in Thermal Conductivity
Toberer, E. S., Baranowski, L. L., & Dames, C. (2012) · Annual Review of Materials Research · doi:10.1146/annurev-matsci-070511-155040 · Cited by 334
Most Efficient Quantum Thermoelectric at Finite Power Output
Whitney, R. S. (2014) · Physical Review Letters · doi:10.1103/physrevlett.112.130601 · Cited by 314
Mean free path spectra as a tool to understand thermal conductivity in bulk and nanostructures
Yang, F., & Dames, C. (2013) · Physical Review B · doi:10.1103/physrevb.87.035437 · Cited by 283
Spectrally Resolved Specular Reflections of Thermal Phonons from Atomically Rough Surfaces
Ravichandran, N. K., Zhang, H., & Minnich, A. J. (2018) · Physical Review X · doi:10.1103/physrevx.8.041004 · Cited by 48
Metadata
- Authors
- Heron, J. S., Fournier, T., Mingo, N., & Bourgeois, O.
- Venue
- Nano Letters
- Publisher
- American Chemical Society (ACS)
- Published
- 2009-03-26
- Volume
- 9
- Issue
- 5
- Pages
- 1861-1865
- ISSN
- 1530-6984 (ISSN-L)
- 1530-6992
- OpenAlex
- W2048779441
- Cited by
- 120
- References
- 4
- FWCI
- 4.94
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.