The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Electrical Recording from Hearts with Flexible Nanowire Device Arrays
Open accessAbstract
We show that nanowire field-effect transistor (NWFET) arrays fabricated on both planar and flexible polymeric substrates can be reproducibly interfaced with spontaneously beating embryonic chicken hearts in both planar and bent conformations. Simultaneous recordings from glass microelectrode and NWFET devices show that NWFET conductance variations are synchronized with the beating heart. The conductance change associated with beating can be tuned substantially by device sensitivity, although the voltage-calibrated signals, 4-6 mV, are relatively constant and typically larger than signals recorded by microelectrode arrays. Multiplexed recording from NWFET arrays yielded signal propagation times across the myocardium with high spatial resolution. The transparent and flexible NWFET chips also enable simultaneous electrical recording and optical registration of devices to heart surfaces in three-dimensional conformations not possible with planar microdevices. The capability of simultaneous optical imaging and electrical recording also could be used to register devices to a specific region of the myocardium at the cellular level, and more generally, NWFET arrays fabricated on increasingly flexible plastic and/or biopolymer substrates have the potential to become unique tools for electrical recording from other tissue/organ samples or as powerful implants.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Exploring and Engineering the Cell Surface Interface
Stevens, M. M., & George, J. H. (2005) · Science · doi:10.1126/science.1106587 · Cited by 2,607
Label-free immunodetection with CMOS-compatible semiconducting nanowires
Stern, E., Klemic, J. F., Routenberg, D. A., Wyrembak, P. N., Turner-Evans, D. B., Hamilton, A. D., LaVan, D. A., Fahmy, T. M., & Reed, M. A. (2007) · Nature · doi:10.1038/nature05498 · Cited by 1,352
Cited by
Nanotechnological strategies for engineering complex tissues
Dvir, T., Timko, B. P., Kohane, D. S., & Langer, R. (2011) · Nature Nanotechnology · doi:10.1038/nnano.2010.246 · Cited by 1,367
Self-citationUltrathin, highly flexible and stretchable PLEDs
White, M. S., Kaltenbrunner, M., Głowacki, E. D., Gutnichenko, K., Kettlgruber, G., Graz, I., Aazou, S., Ulbricht, C., Egbe, D. A. M., Miron, M. C., et al. (2013) · Nature Photonics · doi:10.1038/nphoton.2013.188 · Cited by 938
Mannoor, M. S., Jiang, Z., James, T., Kong, Y. L., Malatesta, K. A., Soboyejo, W. O., Verma, N., Gracias, D. H., & McAlpine, M. C. (2013) · Nano Letters · doi:10.1021/nl4007744 · Cited by 874
Nanowired three-dimensional cardiac patches
Dvir, T., Timko, B. P., Brigham, M. D., Naik, S. R., Karajanagi, S. S., Levy, O., Jin, H., Parker, K. K., Langer, R., & Kohane, D. S. (2011) · Nature Nanotechnology · doi:10.1038/nnano.2011.160 · Cited by 760
Self-citationSyringe-injectable electronics
Liu, J., Fu, T.-M., Cheng, Z., Hong, G., Zhou, T., Jin, L., Duvvuri, M., Jiang, Z., Kruskal, P., Xie, C., et al. (2015) · Nature Nanotechnology · doi:10.1038/nnano.2015.115 · Cited by 687
Self-citation
Metadata
- Authors
- Timko, B. P., Cohen-Karni, T., Yu, G., Qing, Q., Tian, B., & Lieber, C. M.
- Venue
- Nano Letters
- Publisher
- American Chemical Society (ACS)
- Published
- 2009-01-26
- Volume
- 9
- Issue
- 2
- Pages
- 914-918
- ISSN
- 1530-6984 (ISSN-L)
- 1530-6992
- OpenAlex
- W2122482341
- Cited by
- 215
- References
- 2
- FWCI
- 9.28
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Electrical Recording from Hearts with Flexible Nanowire Device Arrays. https://app.cochat.ai/papers/10.1021/nl900096z
- The paper
- Timko, B. P., Cohen-Karni, T., Yu, G., Qing, Q., Tian, B., & Lieber, C. M. (2009). Electrical Recording from Hearts with Flexible Nanowire Device Arrays. Nano Letters. https://doi.org/10.1021/nl900096z
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.