The DOI matches its Crossref record.
Long-Range Fluorescence Quenching by Gold Nanoparticles in a Sandwich Immunoassay for Cardiac Troponin T
Abstract
We report the first homogeneous sandwich immunoassay with gold nanoparticles (AuNPs) as fluorescence quenchers. The sandwich assay is designed for the detection of the protein cardiac troponin T (cTnT) by its simultaneous interaction with two different antibodies, one attached to AuNPs and the other labeled with fluorescent dyes. We demonstrate the working principle of the assay and using time-resolved fluorescence spectroscopy, we determine the quenching efficiency of the gold nanoparticles. In spite of the relatively large separation distance between dye molecules and AuNPs, ranging from 3 to 22 nm, the AuNPs quench the fluorescence with efficiencies as high as 95%. A limit of detection of 0.02 nM (0.7 ng/mL) was obtained for cTnT, which is the lowest value reported for a homogeneous sandwich assay for cTnT. These results illustrate the use of metallic nanoparticles as fluorescence quenchers in immunoassays where the large biomolecules involved impose distances for which energy transfer between fluorophores would be inefficient.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Functional Gold Nanorods: Synthesis, Self‐Assembly, and Sensing Applications
Vigderman, L., Khanal, B. P., & Zubarev, E. R. (2012) · Advanced Materials · doi:10.1002/adma.201201690 · Cited by 777
Noble Metal Nanoparticles for Biosensing Applications
Doria, G., Conde, J., Veigas, B., Giestas, L., Almeida, C., Assunção, M., Rosa, J., & Baptista, P. V. (2012) · Sensors · doi:10.3390/s120201657 · Cited by 708
Nanoparticle-Based Immunochemical Biosensors and Assays: Recent Advances and Challenges
Farka, Z., Juřík, T., Kovář, D., Trnková, L., & Skládal, P. (2017) · Chemical Reviews · doi:10.1021/acs.chemrev.7b00037 · Cited by 694
Nanostructured Sensors for Detection of Heavy Metals: A Review
Li, M., Gou, H., Al-Ogaidi, I., & Wu, N. (2013) · ACS Sustainable Chemistry & Engineering · doi:10.1021/sc400019a · Cited by 606
Conde, J., Dias, J. T., Grazú, V., Moros, M., Baptista, P. V., & de la Fuente, J. M. (2014) · Frontiers in Chemistry · doi:10.3389/fchem.2014.00048 · Cited by 425
Metadata
- Authors
- Mayilo, S., Kloster, M. A., Wunderlich, M., Lutich, A., Klar, T. A., Nichtl, A., Kürzinger, K., Stefani, F. D., & Feldmann, J.
- Venue
- Nano Letters
- Publisher
- American Chemical Society (ACS)
- Published
- 2009-11-18
- Volume
- 9
- Issue
- 12
- Pages
- 4558-4563
- ISSN
- 1530-6984 (ISSN-L)
- 1530-6992
- OpenAlex
- W1983586473
- Cited by
- 213
- References
- 0
- FWCI
- 8.52
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Long-Range Fluorescence Quenching by Gold Nanoparticles in a Sandwich Immunoassay for Cardiac Troponin T. https://app.cochat.ai/papers/10.1021/nl903178n
- The paper
- Mayilo, S., Kloster, M. A., Wunderlich, M., Lutich, A., Klar, T. A., Nichtl, A., Kürzinger, K., Stefani, F. D., & Feldmann, J. (2009). Long-Range Fluorescence Quenching by Gold Nanoparticles in a Sandwich Immunoassay for Cardiac Troponin T. Nano Letters. https://doi.org/10.1021/nl903178n
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.