Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 300

The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.

Highly Sensitive Biosensing Using Arrays of Plasmonic Au Nanodisks Realized by Nanoimprint Lithography

Lee, Seung-Woo, Lee, Kyeong-Seok, Ahn, Junhyoung, Lee, Jae-Jong, Kim, Min-Gon, Shin, Yong-Beom·2011·ACS Nano

Abstract

We describe the fabrication of elliptical Au nanodisk arrays as a localized surface plasmon resonance (LSPR) sensing substrate for clinical immunoassay via thermal nanoimprint lithography (NIL) and enhancement in the sensitivity of the detection of the prostate-specific antigen (PSA) using the precipitation of 5-bromo-4-chloro-3-indolyl phosphate p-toluidine/nitro blue tetrazolium (BCIP/NBT), catalyzed by alkaline phosphatase. Au nanodisks were fabricated on glass through an unconventional tilted evaporation, which could preserve the thickness of imprinted resists and create an undercut beneficial to the subsequent lift-off process without any damage to pattern dimension and the glass while removing the residual polymers. To investigate the optically anisotropic property of the LSPR sensors, a probe light with linear polarization parallel to and perpendicular to the long axis of the elliptical nanodisk array was utilized, and their sensitivity to the bulk refractive index (RI) was measured as 327 and 167 nm/RIU, respectively. To our knowledge, this is the first application of enzyme-substrate reaction to sandwich immunoassay-based LSPR biosensors that previously suffered from a low sensitivity due to the short penetration depth of the plasmon field, especially when large-sized antibodies were used as bioreceptors. As a result, a large change in local refractive index because of the precipitation on the Au nanodisks amplified the wavelength shift of the LSPR peak in the vis-NIR spectrum, resulting in femtomolar detection limits, which was ∼10(5)-fold lower than the label-free detection without the enzyme precipitation. This method can be extended easily to the other clinical diagnostics with a high sensitivity.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1021/nn102041m

Cites

1 of 1 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 300

Metadata

Authors
Lee, S.-W., Lee, K.-S., Ahn, J., Lee, J.-J., Kim, M.-G., & Shin, Y.-B.
Venue
ACS Nano
Published
2011-01-11
Volume
5
Issue
2
Pages
897-904
ISSN
  • 1936-0851 (ISSN-L)
  • 1936-086X
OpenAlex
W1988327598
Cited by
300
References
1
FWCI
12.22
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Highly Sensitive Biosensing Using Arrays of Plasmonic Au Nanodisks Realized by Nanoimprint Lithography. https://app.cochat.ai/papers/10.1021/nn102041m
The paper
Lee, S.-W., Lee, K.-S., Ahn, J., Lee, J.-J., Kim, M.-G., & Shin, Y.-B. (2011). Highly Sensitive Biosensing Using Arrays of Plasmonic Au Nanodisks Realized by Nanoimprint Lithography. ACS Nano. https://doi.org/10.1021/nn102041m

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.