CoChat

Ultralight Multiwalled Carbon Nanotube Aerogel

Open access

The DOI matches its Crossref record; 60 of the 62 references it cites were found in a registry or an index.

Abstract

Ultralight multiwalled carbon nanotube (MWCNT) aerogel is fabricated from a wet gel of well-dispersed pristine MWCNTs. On the basis of a theoretical prediction that increasing interaction potential between CNTs lowers their critical concentration to form an infinite percolation network, poly(3-(trimethoxysilyl) propyl methacrylate) (PTMSPMA) is used to disperse and functionalize MWCNTs where the subsequent hydrolysis and condensation of PTMSPMA introduces strong and permanent chemical bonding between MWCNTs. The interaction is both experimentally and theoretically proven to facilitate the formation of a MWCNT percolation network, which leads to the gelation of MWCNT dispersion at ultralow MWCNT concentration. After removing the liquid component from the MWCNT wet gel, the lightest ever free-standing MWCNT aerogel monolith with a density of 4 mg/cm(3) is obtained. The MWCNT aerogel has an ordered macroporous honeycomb structure with straight and parallel voids in 50-150 μm separated by less than 100 nm thick walls. The entangled MWCNTs generate mesoporous structures on the honeycomb walls, creating aerogels with a surface area of 580 m(2)/g which is much higher than that of pristine MWCNTs (241 m(2)/g). Despite the ultralow density, the MWCNT aerogels have an excellent compression recoverable property as demonstrated by the compression test. The aerogels have an electrical conductivity of 3.2 × 10(-2) S·cm(-1) that can be further increased to 0.67 S·cm(-1) by a high-current pulse method without degrading their structures. The excellent compression recoverable property, hierarchically porous structure with large surface area, and high conductivity grant the MWCNT aerogels exceptional pressure and chemical vapor sensing capabilities.

Overview

Integrity signals

Registry

Crossref · 10.1021/nn102246a

Cites

60 of 60 references verified0 citation errors · 0 not checkable

Statistics

Recomputing p-values needs the paper’s full text.

Verification

Claims the paper makes

We couldn’t retrieve this paper’s full text, so its claims and self-check weren’t run. The registry and citation checks still apply.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

Citations

Cites

Show all 60 references

Research works printed but not linked: 1

  1. Webb P. A., 1997, Analytical Methods in Fine Particle Technology

Cited by

Items 101–200 of 513

Metadata

Authors
Zou, J., Liu, J., Karakoti, A. S., Kumar, A., Joung, D., Li, Q., Khondaker, S. I., Seal, S., & Zhai, L.
Affiliations
  • NanoScience Technology Center
  • Advanced Materials Processing and Analysis Center
  • Department of Physics
Corresponding author
Zhai, Lei
Venue
ACS Nano
Published
2010-11-22
Volume
4
Issue
12
Pages
7293-7302
ISSN
  • 1936-0851 (ISSN-L)
  • 1936-086X
OpenAlex
W2314021766
Cited by
509
References
62
Citations by year
2026: 12 · 2025: 10 · 2024: 21 · 2023: 16 · 2022: 24 · 2021: 41 · 2020: 39 · 2019: 36 · 2018: 56 · 2017: 50 · 2016: 58 · 2015: 45 · 2014: 38 · 2013: 33 · 2012: 22
FWCI
9.90
Type
journal article
Language
en
Open access
Locations
  • ACS Nano (publishedVersion)
  • PubMed (publishedVersion)
  • Journal of International Crisis and Risk Communication Research (submittedVersion)
Topics
  • Physical Sciences › Materials Science › Materials Chemistry › Carbon Nanotubes in Composites
  • Physical Sciences › Materials Science › Materials Chemistry › Aerogels and thermal insulation
  • Physical Sciences › Materials Science › Electronic, Optical and Magnetic Materials › Electromagnetic wave absorption materials
Keywords
multi-walled carbon nanotubes, carbon nanotube aerogels, ultralight materials, percolation network, silane functionalization, hierarchical porosity, surface area enhancement, electrical conductivity, pressure sensing, chemical vapor sensing

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.