The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Noninvasive Photoacoustic and Fluorescence Sentinel Lymph Node Identification using Dye-Loaded Perfluorocarbon Nanoparticles
Open accessAbstract
The contrast mechanisms used for photoacoustic tomography (PAT) and fluorescence imaging differ in subtle, but significant, ways. The design of contrast agents for each or both modalities requires an understanding of the spectral characteristics as well as intra- and intermolecular interactions that occur during formulation. We found that fluorescence quenching that occurs in the formulation of near-infrared (NIR) fluorescent dyes in nanoparticles results in enhanced contrast for PAT. The ability of the new PAT method to utilize strongly absorbing chromophores for signal generation allowed us to convert a highly fluorescent dye into an exceptionally high PA contrast material. Spectroscopic characterization of the developed NIR dye-loaded perfluorocarbon-based nanoparticles for combined fluorescence and PA imaging revealed distinct dye-dependent photophysical behavior. We demonstrate that the enhanced contrast allows detection of regional lymph nodes of rats in vivo with time-domain optical and photoacoustic imaging methods. The results further show that the use of fluorescence lifetime imaging, which is less dependent on fluorescence intensity, provides a strategic approach to bridge the disparate contrast reporting mechanisms of fluorescence and PA imaging methods.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Pyrrolopyrrole Cyanine Dyes: A New Class of Near‐Infrared Dyes and Fluorophores
Fischer, G. M., Isomäki‐Krondahl, M., Göttker‐Schnetmann, I., Daltrozzo, E., & Zumbusch, A. (2009) · Chemistry – A European Journal · doi:10.1002/chem.200801996 · Cited by 144
Self-citation
Cited by
Photothermal therapy and photoacoustic imaging via nanotheranostics in fighting cancer
Liu, Y., Bhattarai, P., Dai, Z., & Chen, X. (2019) · Chemical Society Reviews · doi:10.1039/c8cs00618k · Cited by 2,904
Semiconducting polymer nanoparticles as photoacoustic molecular imaging probes in living mice
Pu, K., Shuhendler, A. J., Jokerst, J. V., Mei, J., Gambhir, S. S., Bao, Z., & Rao, J. (2014) · Nature Nanotechnology · doi:10.1038/nnano.2013.302 · Cited by 1,185
The unique role of nanoparticles in nanomedicine: imaging, drug delivery and therapy
Doane, T. L., & Burda, C. (2012) · Chemical Society Reviews · doi:10.1039/c2cs15260f · Cited by 1,098
Polymer-encapsulated organic nanoparticles for fluorescence and photoacoustic imaging
Li, K., & Liu, B. (2014) · Chem. Soc. Rev. · doi:10.1039/c4cs00014e · Cited by 987
Yao, J., & Wang, L. V. (2013) · Laser & Photonics Reviews · doi:10.1002/lpor.201200060 · Cited by 616
Self-citationMolecular Interactions in Organic Nanoparticles for Phototheranostic Applications
Ng, K. K., & Zheng, G. (2015) · Chemical Reviews · doi:10.1021/acs.chemrev.5b00140 · Cited by 609
Nanotheranostics for personalized medicine
Mura, S., & Couvreur, P. (2012) · Advanced Drug Delivery Reviews · doi:10.1016/j.addr.2012.06.006 · Cited by 527
Applications of nanoparticles for diagnosis and therapy of cancer
Baetke, S. C., Lammers, T., & Kiessling, F. (2015) · The British Journal of Radiology · doi:10.1259/bjr.20150207 · Cited by 494
Light In and Sound Out: Emerging Translational Strategies for Photoacoustic Imaging
Zackrisson, S., van de Ven, S. M. W. Y., & Gambhir, S. S. (2014) · Cancer Research · doi:10.1158/0008-5472.can-13-2387 · Cited by 480
Li, J., Rao, J., & Pu, K. (2018) · Biomaterials · doi:10.1016/j.biomaterials.2017.11.025 · Cited by 469
Structural and functional photoacoustic molecular tomography aided by emerging contrast agents
Nie, L., & Chen, X. (2014) · Chem. Soc. Rev. · doi:10.1039/c4cs00086b · Cited by 383
Nanoscale Metal–Organic Frameworks for Real-Time Intracellular pH Sensing in Live Cells
He, C., Lu, K., & Lin, W. (2014) · Journal of the American Chemical Society · doi:10.1021/ja507333c · Cited by 294
Advanced Photoacoustic Imaging Applications of Near‐Infrared Absorbing Organic Nanoparticles
Jiang, Y., & Pu, K. (2017) · Small · doi:10.1002/smll.201700710 · Cited by 277
Fan, Q., Cheng, K., Yang, Z., Zhang, R., Yang, M., Hu, X., Ma, X., Bu, L., Lu, X., Xiong, X., et al. (2015) · Advanced Materials · doi:10.1002/adma.201402972 · Cited by 264
Semiconducting polymer dots with bright narrow-band emission at 800 nm for biological applications
Chen, D., Wu, I.-C., Liu, Z., Tang, Y., Chen, H., Yu, J., Wu, C., & Chiu, D. T. (2017) · Chemical Science · doi:10.1039/c7sc00441a · Cited by 78
Metadata
- Authors
- Akers, W. J., Kim, C., Berezin, M., Guo, K., Fuhrhop, R., Lanza, G. M., Fischer, G. M., Daltrozzo, E., Zumbusch, A., Cai, X., Wang, L. V., & Achilefu, S.
- Venue
- ACS Nano
- Publisher
- American Chemical Society (ACS)
- Published
- 2010-12-20
- Volume
- 5
- Issue
- 1
- Pages
- 173-182
- ISSN
- 1936-0851 (ISSN-L)
- 1936-086X
- OpenAlex
- W2122426907
- Cited by
- 192
- References
- 1
- FWCI
- 8.19
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.