The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Sensitivity and Optimization of Localized Surface Plasmon Resonance Transducers
Abstract
Gold nanoisland films displaying localized surface plasmon resonance optical response were constructed by evaporation on glass and annealing. The surface plasmon distance sensitivity and refractive index sensitivity (RIS) for island films of different nominal thicknesses and morphologies were investigated using layer-by-layer polyelectrolyte multilayer assembly. Since the polymer forms a conformal coating on the Au islands and the glass substrate between islands, the relative sensitivity of the optical response to adsorption on and between islands was evaluated. The RIS was also determined independently using a series of solvents. An apparent discrepancy between the behavior of the RIS for wavelength shift and intensity change is resolved by considering the different physical nature of the two quantities, leading to the use of a new variable, that is, RIS (for intensity change) normalized to the surface density of islands. In the present system the surface plasmon decay length and RIS are shown to be directly correlated; both parameters increase with increasing average island size. This result implies that a higher RIS is not always beneficial for sensing; maximizing the transducer optical response requires the interrelated RIS and decay length to be optimized with respect to the dimensions of the studied analyte-receptor system. It is shown that, as a rule, transducers comprising larger islands furnish better overall sensitivity for thicker adlayers, whereas thinner adlayers produce a larger response when sensed using transducers comprising smaller islands, despite the lower RIS of the latter.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Haes, A. J., & Van Duyne, R. P. (2002) · Journal of the American Chemical Society · doi:10.1021/ja020393x · Cited by 2,057
Cited by
Advances and applications of nanophotonic biosensors
Altug, H., Oh, S.-H., Maier, S. A., & Homola, J. (2022) · Nature Nanotechnology · doi:10.1038/s41565-021-01045-5 · Cited by 882
Optical Biosensors Based on Plasmonic Nanostructures: A Review
Spackova, B., Wrobel, P., Bockova, M., & Homola, J. (2016) · Proceedings of the IEEE · doi:10.1109/jproc.2016.2624340 · Cited by 421
Ben-Moshe, A., Maoz, B. M., Govorov, A. O., & Markovich, G. (2013) · Chemical Society Reviews · doi:10.1039/c3cs60139k · Cited by 378
Amplification of Chiroptical Activity of Chiral Biomolecules by Surface Plasmons
Maoz, B. M., Chaikin, Y., Tesler, A. B., Bar Elli, O., Fan, Z., Govorov, A. O., & Markovich, G. (2013) · Nano Letters · doi:10.1021/nl304638a · Cited by 268
Self-citationGeidel, S., Peransi Llopis, S., Rodrigo, M., De Diego-Castilla, G., Sousa, A., Nestler, J., Otto, T., Gessner, T., & Parro, V. (2016) · Micromachines · doi:10.3390/mi7090153 · Cited by 26
Metadata
- Authors
- Kedem, O., Tesler, A. B., Vaskevich, A., & Rubinstein, I.
- Venue
- ACS Nano
- Publisher
- American Chemical Society (ACS)
- Published
- 2011-01-12
- Volume
- 5
- Issue
- 2
- Pages
- 748-760
- ISSN
- 1936-0851 (ISSN-L)
- 1936-086X
- OpenAlex
- W1969447791
- Cited by
- 175
- References
- 1
- FWCI
- 11.12
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.