CoChat

Integration of an Optical Ring Resonator Biosensor into a Self-Contained Microfluidic Cartridge with Active, Single-Shot Micropumps

Open access
Geidel, Sascha, Peransi Llopis, Sergio, Rodrigo, Manuel, De Diego-Castilla, Graciela, Sousa, Antonio, Nestler, Jörg, Otto, Thomas, Gessner, Thomas, Parro, Victor · 2016 · Micromachines

The DOI matches its Crossref record; 27 of the 27 references it cites were found in a registry or an index.

Abstract

While there have been huge advances in the field of biosensors during the last decade, their integration into a microfluidic environment avoiding external tubing and pumping is still neglected. Herein, we show a new microfluidic design that integrates multiple reservoirs for reagent storage and single-use electrochemical pumps for time-controlled delivery of the liquids. The cartridge has been tested and validated with a silicon nitride-based photonic biosensor incorporating multiple optical ring resonators as sensing elements and an immunoassay as a potential target application. Based on experimental results obtained with a demonstration model, subcomponents were designed and existing protocols were adapted. The newly-designed microfluidic cartridges and photonic sensors were separately characterized on a technical basis and performed well. Afterwards, the sensor was functionalized for a protein detection. The microfluidic cartridge was loaded with the necessary assay reagents. The integrated pumps were programmed to drive the single process steps of an immunoassay. The prototype worked selectively, but only with a low sensitivity. Further work must be carried out to optimize biofunctionalization of the optical ring resonators and to have a more suitable flow velocity progression to enhance the system’s reproducibility.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.3390/mi7090153

Cites

27 of 27 references verified0 citation errors · 0 not checkable

Statistics

Figures

Figure 1 Manufacturing and characterization methodologies used for the fabrication of the photonic sensor: (a) cross-section showing the final layer structure of a photonic sensor with optical waveguides secured by an oxide and optical ring resonators in contact with the surrounding environment; (b) SEM picture of optical waveguides within silicon nitride. SEM images are done for technical characterization reasons of the single features by spot testing; and (c) response signal of an exemplary optical ring resonator. The included labels refer to central parameters describing the performance of each resonator.
Figure 1 Manufacturing and characterization methodologies used for the fabrication of the photonic sensor: (a) cross-section showing the final layer structure of a photonic sensor with optical waveguides secured by an oxide and optical ring resonators in contact with the surrounding environment; (b) SEM picture of optical waveguides within silicon nitride. SEM images are done for technical characterization reasons of the single features by spot testing; and (c) response signal of an exemplary optical ring resonator. The included labels refer to central parameters describing the performance of each resonator.CC BY · PubMed Central
Figure 2 Demonstration model: (a) a standard flex.flow cartridge used for the study of the interfacing method between a microfluidic cartridge and the photonic sensor; (b) flow cell developed to form a sensor chamber on top of the optical ring resonators; (c) picture of the experimental setup with optical fibers aligned to the demonstration model; and (d) plot of the resonance frequency shift of the observed optical ring resonator, while different concentrations of phosphate buffered saline (PBS) are pumped through the sensor chamber.
Figure 2 Demonstration model: (a) a standard flex.flow cartridge used for the study of the interfacing method between a microfluidic cartridge and the photonic sensor; (b) flow cell developed to form a sensor chamber on top of the optical ring resonators; (c) picture of the experimental setup with optical fibers aligned to the demonstration model; and (d) plot of the resonance frequency shift of the observed optical ring resonator, while different concentrations of phosphate buffered saline (PBS) are pumped through the sensor chamber.CC BY · PubMed Central
Figure 3 The picture of the newly-designed cartridge shows the reservoirs filled with colored water except the sample reservoirs. The sample is filled into the corresponding reservoirs using an external manipulator through tubing’s connected to a port with high performance liquid chromatography (HPLC)-fitting compatible threadings. The PIC is not shown here.
Figure 3 The picture of the newly-designed cartridge shows the reservoirs filled with colored water except the sample reservoirs. The sample is filled into the corresponding reservoirs using an external manipulator through tubing’s connected to a port with high performance liquid chromatography (HPLC)-fitting compatible threadings. The PIC is not shown here.CC BY · PubMed Central
Figure 4 Design of the photonic sensor: (a) microscope image of a part of the photonic sensor with optical ring resonators (a1), optical waveguides (a2), and optical interfaces on the right (a3); (b) drawing of the whole circuit’s layout with an array of optical grating couplers on the left (b1) and on the right (b3) connected by a waveguide (b2). Optical ring resonators are located in the middle of the chip (b5). The black frame (b4) is not a part of the chip. It marks the area where the liquids will be pumped through; (c) detailed design of an optical ring resonator within the photonic sensor. An optical waveguide (c1) passes the optical ring resonator (c3) at a small area (c2); and (d) a schematic sketch of the fluidic connection of a polymer based cartridge (d8) and a silicon chip d4 using an elastomer sealing ring (d6). The direction of the pumped liquids is visualized by arrows.
Figure 4 Design of the photonic sensor: (a) microscope image of a part of the photonic sensor with optical ring resonators (a1), optical waveguides (a2), and optical interfaces on the right (a3); (b) drawing of the whole circuit’s layout with an array of optical grating couplers on the left (b1) and on the right (b3) connected by a waveguide (b2). Optical ring resonators are located in the middle of the chip (b5). The black frame (b4) is not a part of the chip. It marks the area where the liquids will be pumped through; (c) detailed design of an optical ring resonator within the photonic sensor. An optical waveguide (c1) passes the optical ring resonator (c3) at a small area (c2); and (d) a schematic sketch of the fluidic connection of a polymer based cartridge (d8) and a silicon chip d4 using an elastomer sealing ring (d6). The direction of the pumped liquids is visualized by arrows.CC BY · PubMed Central
Figure 5 Data achieved by the pump characterization process of (a) 45 µL reservoirs and (b) 25 µL reservoirs. Each graph shows the arithmetic mean of the measured flow velocity achieved by an electrolysis reaction. The failure tube is formed by the standard deviation of 13 reservoirs with a volume of 25 µL and eight reservoirs with a volume of 45 µL.
Figure 5 Data achieved by the pump characterization process of (a) 45 µL reservoirs and (b) 25 µL reservoirs. Each graph shows the arithmetic mean of the measured flow velocity achieved by an electrolysis reaction. The failure tube is formed by the standard deviation of 13 reservoirs with a volume of 25 µL and eight reservoirs with a volume of 45 µL.CC BY · PubMed Central
Figure 6 Measurements taken by the photonic sensor. Depicted is the response of four different optical ring resonators of one photonic sensor. The response signals are well defined and each separate frequency shift of one optical ring resonator can be easily tracked.
Figure 6 Measurements taken by the photonic sensor. Depicted is the response of four different optical ring resonators of one photonic sensor. The response signals are well defined and each separate frequency shift of one optical ring resonator can be easily tracked.CC BY · PubMed Central
Figure 7 Optofluidic immunoassay. Results of an immunoassay experiment automatically performed by the microfluidic cartridge and monitored by the photonic sensor. With a differential frequency shift of 60 pm, only the labeled measurement, which was enhanced with functionalized nanoparticles, showed a significant signal increase.
Figure 7 Optofluidic immunoassay. Results of an immunoassay experiment automatically performed by the microfluidic cartridge and monitored by the photonic sensor. With a differential frequency shift of 60 pm, only the labeled measurement, which was enhanced with functionalized nanoparticles, showed a significant signal increase.CC BY · PubMed Central

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 27 references

Cited by

See all 26

Metadata

Authors
Geidel, S., Peransi Llopis, S., Rodrigo, M., De Diego-Castilla, G., Sousa, A., Nestler, J., Otto, T., Gessner, T., & Parro, V.
Affiliations
  • Fraunhofer Institute for Electronic Nano Systems (DE)
  • DAS Photonics S.L., Valencia 46022, Spain
  • Centro de Astrobiología (INTA-CSIC), Torrejon de Ardoz 28850, Spain
  • Evoleo Technologies Lda, 442565 Maia, Portugal
  • Berlin Institute for the Foundations of Learning and Data (DE)
Corresponding author
Geidel, Sascha
Venue
Micromachines
Publisher
MDPI AG
Published
2016-09-13
Volume
7
Issue
9
Pages
153
ISSN
2072-666X (ISSN-L)
OpenAlex
W2518754193
Cited by
26
References
27
Citations by year
2026: 3 · 2025: 1 · 2024: 2 · 2023: 1 · 2022: 1 · 2021: 1 · 2020: 4 · 2019: 5 · 2018: 7 · 2017: 1
FWCI
2.09
Type
journal article
Language
en
Open access
Locations
  • Micromachines (publishedVersion, cc-by)
  • Europe PMC (PubMed Central) (publishedVersion, other-oa)
  • PubMed Central (publishedVersion, cc-by)
  • PubMed (publishedVersion)
  • DIGITAL.CSIC (Spanish National Research Council (CSIC)) (submittedVersion)
  • DOAJ (DOAJ: Directory of Open Access Journals) (submittedVersion, cc-by-sa)
  • Fraunhofer-Publica (Fraunhofer-Gesellschaft) (submittedVersion)
Funders
European Commission (312942-PBSA)
Topics
  • Physical Sciences › Engineering › Biomedical Engineering › Microfluidic and Capillary Electrophoresis Applications
  • Physical Sciences › Engineering › Electrical and Electronic Engineering › Photonic and Optical Devices
  • Physical Sciences › Engineering › Biomedical Engineering › Biosensors and Analytical Detection
Keywords
microfluidic cartridge, immunoassay, protein detection, biofunctionalization

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Integration of an Optical Ring Resonator Biosensor into a Self-Contained Microfluidic Cartridge with Active, Single-Shot Micropumps. https://app.cochat.ai/papers/10.3390/mi7090153
The paper
Geidel, S., Peransi Llopis, S., Rodrigo, M., De Diego-Castilla, G., Sousa, A., Nestler, J., Otto, T., Gessner, T., & Parro, V. (2016). Integration of an Optical Ring Resonator Biosensor into a Self-Contained Microfluidic Cartridge with Active, Single-Shot Micropumps. Micromachines. https://doi.org/10.3390/mi7090153

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.