The DOI matches its Crossref record; 44 of the 44 references it cites were found in a registry or an index.
Precise Subnanometer Plasmonic Junctions for SERS within Gold Nanoparticle Assemblies Using Cucurbit[n]uril “Glue”
Abstract
Cucurbit[n]urils (CB[n]) are macrocyclic host molecules with subnanometer dimensions capable of binding to gold surfaces. Aggregation of gold nanoparticles with CB[n] produces a repeatable, fixed, and rigid interparticle separation of 0.9 nm, and thus such assemblies possess distinct and exquisitely sensitive plasmonics. Understanding the plasmonic evolution is key to their use as powerful SERS substrates. Furthermore, this unique spatial control permits fast nanoscale probing of the plasmonics of the aggregates "glued" together by CBs within different kinetic regimes using simultaneous extinction and SERS measurements. The kinetic rates determine the topology of the aggregates including the constituent structural motifs and allow the identification of discrete plasmon modes which are attributed to disordered chains of increasing lengths by theoretical simulations. The CBs directly report the near-field strength of the nanojunctions they create via their own SERS, allowing calibration of the enhancement. Owing to the unique barrel-shaped geometry of CB[n] and their ability to bind "guest" molecules, the aggregates afford a new type of in situ self-calibrated and reliable SERS substrate where molecules can be selectively trapped by the CB[n] and exposed to the nanojunction plasmonic field. Using this concept, a powerful molecular-recognition-based SERS assay is demonstrated by selective cucurbit[n]uril host-guest complexation.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Optical Constants of the Noble Metals
Johnson, P. B., & Christy, R. W. (1972) · Physical Review B · doi:10.1103/physrevb.6.4370 · Cited by 20,094
Absorption and Scattering of Light by Small Particles
Bohren, C. F., & Huffman, D. R. (1998) · doi:10.1002/9783527618156 · Cited by 18,474
Daniel, M.-C., & Astruc, D. (2004) · Chemical Reviews · doi:10.1021/cr030698+ · Cited by 12,446
Probing Single Molecules and Single Nanoparticles by Surface-Enhanced Raman Scattering
Nie, S., & Emory, S. R. (1997) · Science · doi:10.1126/science.275.5303.1102 · Cited by 10,238
Plasmonics: Fundamentals and Applications
Maier, S. A. (2007) · Springer eBooks · doi:10.1007/0-387-37825-1 · Cited by 9,728
Optical Properties of Metal Clusters
Kreibig, U., & Vollmer, M. (1995) · Springer Series in Materials Science · doi:10.1007/978-3-662-09109-8 · Cited by 7,896
Raman spectra of pyridine adsorbed at a silver electrode
Fleischmann, M., Hendra, P. J., & McQuillan, A. J. (1974) · Chemical Physics Letters · doi:10.1016/0009-2614(74)85388-1 · Cited by 7,172
Single Molecule Detection Using Surface-Enhanced Raman Scattering (SERS)
Kneipp, K., Wang, Y., Kneipp, H., Perelman, L. T., Itzkan, I., Dasari, R. R., & Feld, M. S. (1997) · Physical Review Letters · doi:10.1103/physrevlett.78.1667 · Cited by 6,816
Novotny, L., & Hecht, B. (2025) · Cambridge University Press eBooks · doi:10.1017/9781108781503 · Cited by 6,220
Moskovits, M. (1985) · Reviews of Modern Physics · doi:10.1103/revmodphys.57.783 · Cited by 5,466
Cited by
Localized surface plasmon resonance: Nanostructures, bioassays and biosensing—A review
Petryayeva, E., & Krull, U. J. (2011) · Analytica Chimica Acta · doi:10.1016/j.aca.2011.08.020 · Cited by 1,379
Quantum mechanical effects in plasmonic structures with subnanometre gaps
Zhu, W., Esteban, R., Borisov, A. G., Baumberg, J. J., Nordlander, P., Lezec, H. J., Aizpurua, J., & Crozier, K. B. (2016) · Nature Communications · doi:10.1038/ncomms11495 · Cited by 820
Self-citationRaman Techniques: Fundamentals and Frontiers
Jones, R. R., Hooper, D. C., Zhang, L., Wolverson, D., & Valev, V. K. (2019) · Nanoscale Research Letters · doi:10.1186/s11671-019-3039-2 · Cited by 804
Fan, M., Andrade, G. F. S., & Brolo, A. G. (2020) · Analytica Chimica Acta · doi:10.1016/j.aca.2019.11.049 · Cited by 533
Single-Molecule Plasmon Sensing: Current Status and Future Prospects
Taylor, A. B., & Zijlstra, P. (2017) · ACS Sensors · doi:10.1021/acssensors.7b00382 · Cited by 366
Metadata
- Authors
- Taylor, R. W., Lee, T.-C., Scherman, O. A., Esteban, R., Aizpurua, J., Huang, F. M., Baumberg, J. J., & Mahajan, S.
- Venue
- ACS Nano
- Publisher
- American Chemical Society (ACS)
- Published
- 2011-05-06
- Volume
- 5
- Issue
- 5
- Pages
- 3878-3887
- ISSN
- 1936-0851 (ISSN-L)
- 1936-086X
- OpenAlex
- W2104791047
- Cited by
- 355
- References
- 44
- FWCI
- 11.61
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Precise Subnanometer Plasmonic Junctions for SERS within Gold Nanoparticle Assemblies Using Cucurbit[n]uril “Glue”. https://app.cochat.ai/papers/10.1021/nn200250v
- The paper
- Taylor, R. W., Lee, T.-C., Scherman, O. A., Esteban, R., Aizpurua, J., Huang, F. M., Baumberg, J. J., & Mahajan, S. (2011). Precise Subnanometer Plasmonic Junctions for SERS within Gold Nanoparticle Assemblies Using Cucurbit[n]uril “Glue”. ACS Nano. https://doi.org/10.1021/nn200250v
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.