The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Tumor Accumulation of NIR Fluorescent PEG–PLA Nanoparticles: Impact of Particle Size and Human Xenograft Tumor Model
Abstract
Cancer therapies are often terminated due to serious side effects of the drugs. The cause is the nonspecific distribution of chemotherapeutic agents to both cancerous and normal cells. Therefore, drug carriers which deliver their toxic cargo specific to cancer cells are needed. Size is one key parameter for the nanoparticle accumulation in tumor tissues. In the present study the influence of the size of biodegradable nanoparticles was investigated in detail, combining in vivo and ex vivo analysis with comprehensive particle size characterizations. Polyethylene glycol-polyesters poly(lactide) block polymers were synthesized and used for the production of three defined, stable, and nontoxic near-infrared (NIR) dye-loaded nanoparticle batches. Size analysis based on asymmetrical field flow field fractionation coupled with multiangle laser light scattering and photon correlation spectroscopy (PCS) revealed narrow size distribution and permitted accurate size evaluations. Furthermore, this study demonstrates the constraints of particle size data only obtained by PCS. By the multispectral analysis of the Maestro in vivo imaging system the in vivo fate of the nanoparticles next to their accumulation in special red fluorescent DsRed2 expressing HT29 xenografts could be followed. This simultaneous imaging in addition to confocal microscopy studies revealed information about the accumulation characteristics of nanoparticles inside the tumor tissues. This knowledge was further combined with extended size-dependent fluorescence imaging studies at two different xenograft tumor types, the HT29 (colorectal carcinoma) and the A2780 (ovarian carcinoma) cell lines. The combination of two different size measurement methods allowed the characterization of the dependence of nanoparticle accumulation in the tumor on even rather small differences in the nanoparticle size. While two nanoparticle batches (111 and 141 nm in diameter) accumulated efficiently in the human xenograft tumor tissue, the slightly bigger nanoparticles (diameter 166 nm) were rapidly eliminated by the liver.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
New-Concept Chemotherapy by Nanoparticles of Biodegradable Polymers: Where Are We Now?
Feng, S.-S. (2006) · Nanomedicine · doi:10.2217/17435889.1.3.297 · Cited by 1,951
The Mechanism of Uptake of Biodegradable Microparticles in Caco-2 Cells Is Size Dependent
Desai, M. P., Labhasetwar, V., Walter, E., Levy, R. J., & Amidon, G. L. (1997) · Pharmaceutical Research · doi:10.1023/a:1012126301290 · Cited by 858
Cited by
Targeted polymeric therapeutic nanoparticles: design, development and clinical translation
Kamaly, N., Xiao, Z., Valencia, P. M., Radovic-Moreno, A. F., & Farokhzad, O. C. (2012) · Chemical Society Reviews · doi:10.1039/c2cs15344k · Cited by 1,730
The role of micelle size in tumor accumulation, penetration, and treatment
Wang, J., Mao, W., Lock, L. L., Tang, J., Sui, M., Sun, W., Cui, H., Xu, D., & Shen, Y. (2015) · ACS Nano · doi:10.1021/acsnano.5b02017 · Cited by 635
Fluorescent Polymer Nanoparticles Based on Dyes: Seeking Brighter Tools for Bioimaging
Reisch, A., & Klymchenko, A. S. (2016) · Small · doi:10.1002/smll.201503396 · Cited by 634
Shi, C., Wu, J. B., & Pan, D. (2016) · Journal of Biomedical Optics · doi:10.1117/1.jbo.21.5.050901 · Cited by 286
Molecular imaging of the tumor microenvironment
Zhou, Z., & Lu, Z.-R. (2017) · Advanced Drug Delivery Reviews · doi:10.1016/j.addr.2016.07.012 · Cited by 253
Metadata
- Authors
- Schädlich, A., Caysa, H., Mueller, T., Tenambergen, F., Rose, C., Göpferich, A., Kuntsche, J., & Mäder, K.
- Venue
- ACS Nano
- Publisher
- American Chemical Society (ACS)
- Published
- 2011-10-10
- Volume
- 5
- Issue
- 11
- Pages
- 8710-8720
- ISSN
- 1936-0851 (ISSN-L)
- 1936-086X
- OpenAlex
- W1988587530
- Cited by
- 161
- References
- 2
- FWCI
- 6.30
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.