The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.
Quantifying the Coverage Density of Poly(ethylene glycol) Chains on the Surface of Gold Nanostructures
Open accessAbstract
The coverage density of poly(ethylene glycol) (PEG) is a key parameter in determining the efficiency of PEGylation, a process pivotal to in vivo delivery and targeting of nanomaterials. Here we report four complementary methods for quantifying the coverage density of PEG chains on various types of Au nanostructures by using a model system based on HS-PEG-NH(2) with different molecular weights. Specifically, the methods involve reactions with fluorescamine and ninhydrin, as well as labeling with fluorescein isothiocyanate (FITC) and Cu(2+) ions. The first two methods use conventional amine assays to measure the number of unreacted HS-PEG-NH(2) molecules left behind in the solution after incubation with the Au nanostructures. The other two methods involve coupling between the terminal -NH(2) groups of adsorbed -S-PEG-NH(2) chains and FITC or a ligand for Cu(2+) ion, and thus pertain to the "active" -NH(2) groups on the surface of a Au nanostructure. We found that the coverage density decreased as the length of PEG chains increased. A stronger binding affinity of the initial capping ligand to the Au surface tended to reduce the PEGylation efficiency by slowing down the ligand exchange process. For the Au nanostructures and capping ligands we have tested, the PEGylation efficiency decreased in the order of citrate-capped nanoparticles > PVP-capped nanocages ≈ CTAC-capped nanoparticles ≫ CTAB-capped nanorods, where PVP, CTAC, and CTAB stand for poly(vinyl pyrrolidone), cetyltrimethylammonium chloride, and cetyltrimethylammonium bromide, respectively.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Nanocarriers as an emerging platform for cancer therapy
Peer, D., Karp, J. M., Hong, S., Farokhzad, O. C., Margalit, R., & Langer, R. (2007) · Nature Nanotechnology · doi:10.1038/nnano.2007.387 · Cited by 8,710
Nanostructures in Biodiagnostics
Rosi, N. L., & Mirkin, C. A. (2005) · Chemical Reviews · doi:10.1021/cr030067f · Cited by 4,603
Poly(ethylene glycol) in Drug Delivery: Pros and Cons as Well as Potential Alternatives
Knop, K., Hoogenboom, R., Fischer, D., & Schubert, U. S. (2010) · Angewandte Chemie International Edition · doi:10.1002/anie.200902672 · Cited by 3,533
Cited by
PEGylation as a strategy for improving nanoparticle-based drug and gene delivery
Suk, J. S., Xu, Q., Kim, N., Hanes, J., & Ensign, L. M. (2016) · Advanced Drug Delivery Reviews · doi:10.1016/j.addr.2015.09.012 · Cited by 4,523
Engineered Nanoparticles for Drug Delivery in Cancer Therapy
Sun, T., Zhang, Y. S., Pang, B., Hyun, D. C., Yang, M., & Xia, Y. (2014) · Angewandte Chemie International Edition · doi:10.1002/anie.201403036 · Cited by 2,164
Self-citationGold Nanomaterials at Work in Biomedicine
Yang, X., Yang, M., Pang, B., Vara, M., & Xia, Y. (2015) · Chemical Reviews · doi:10.1021/acs.chemrev.5b00193 · Cited by 1,162
Self-citationXia, X., Wang, Y., Ruditskiy, A., & Xia, Y. (2013) · Advanced Materials · doi:10.1002/adma.201302820 · Cited by 1,019
Self-citationSERS Nanoparticles in Medicine: From Label-Free Detection to Spectroscopic Tagging
Lane, L. A., Qian, X., & Nie, S. (2015) · Chemical Reviews · doi:10.1021/acs.chemrev.5b00265 · Cited by 873
Metadata
- Authors
- Xia, X., Yang, M., Wang, Y., Zheng, Y., Li, Q., Chen, J., & Xia, Y.
- Venue
- ACS Nano
- Publisher
- American Chemical Society (ACS)
- Published
- 2011-12-19
- Volume
- 6
- Issue
- 1
- Pages
- 512-522
- ISSN
- 1936-0851 (ISSN-L)
- 1936-086X
- OpenAlex
- W2094864238
- Cited by
- 239
- References
- 3
- FWCI
- 6.18
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Quantifying the Coverage Density of Poly(ethylene glycol) Chains on the Surface of Gold Nanostructures. https://app.cochat.ai/papers/10.1021/nn2038516
- The paper
- Xia, X., Yang, M., Wang, Y., Zheng, Y., Li, Q., Chen, J., & Xia, Y. (2012). Quantifying the Coverage Density of Poly(ethylene glycol) Chains on the Surface of Gold Nanostructures. ACS Nano. https://doi.org/10.1021/nn2038516
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.