The DOI matches its Crossref record; 4 of the 4 references it cites were found in a registry or an index.
Receptor-Mediated Delivery of Magnetic Nanoparticles across the Blood–Brain Barrier
Abstract
A brain delivery probe was prepared by covalently conjugating lactoferrin (Lf) to a poly(ethylene glycol) (PEG)-coated Fe(3)O(4) nanoparticle in order to facilitate the transport of the nanoparticles across the blood-brain barrier (BBB) by receptor-mediated transcytosis via the Lf receptor present on cerebral endothelial cells. The efficacy of the Fe(3)O(4)-Lf conjugate to cross the BBB was evaluated in vitro using a cell culture model for the blood-brain barrier as well as in vivo in SD rats. For an in vitro experiment, a well-established porcine BBB model was used based on the primary culture of cerebral capillary endothelial cells grown on filter supports, thus allowing one to follow the transfer of nanoparticles from the apical (blood) to the basolateral (brain) side. For in vivo experiments, SD rats were used as animal model to detect the passage of the nanoparticles through the BBB by MRI techniques. The results of both in vitro and in vivo experiments revealed that the Fe(3)O(4)-Lf probe exhibited an enhanced ability to cross the BBB in comparison to the PEG-coated Fe(3)O(4) nanoparticles and further suggested that the Lf-receptor-mediated transcytosis was an effective measure for delivering the nanoparticles across the BBB.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Astrocyte-endothelial interactions at the blood-brain barrier
Abbott, N. J., Rönnbäck, L., & Hansson, E. (2006) · Nature Reviews Neuroscience · doi:10.1038/nrn1824 · Cited by 5,595
Superparamagnetic iron oxide nanoparticles: from preparations to in vivo MRI applications
Qiao, R., Yang, C., & Gao, M. (2009) · Journal of Materials Chemistry · doi:10.1039/b902394a · Cited by 685
Self-citationDelivery of therapeutic agents to the central nervous system: the problems and the possibilities
Begley, D. J. (2004) · Pharmacology & Therapeutics · doi:10.1016/j.pharmthera.2004.08.001 · Cited by 679
Long-circulating pegylated polycyanoacrylate nanoparticles as new drug carrier for brain delivery.
Calvo, P., Gouritin, B., Chacun, H., Desmaële, D., D'Angelo, J., Noel, J.-P., Georgin, D., Fattal, E., Andreux, J. P., & Couvreur, P. (2001) · Pharmaceutical Research · doi:10.1023/a:1010931127745 · Cited by 443
Cited by
The blood–brain barrier: Structure, regulation and drug delivery
Wu, D., Chen, Q., Chen, X., Han, F., Chen, Z., & Wang, Y. (2023) · Signal Transduction and Targeted Therapy · doi:10.1038/s41392-023-01481-w · Cited by 1,906
Helms, H. C., Abbott, N. J., Burek, M., Cecchelli, R., Couraud, P.-O., Deli, M. A., Förster, C., Galla, H. J., Romero, I. A., Shusta, E. V., et al. (2016) · Journal of Cerebral Blood Flow & Metabolism · doi:10.1177/0271678x16630991 · Cited by 843
Self-citationMussel-Inspired Polydopamine: A Biocompatible and Ultrastable Coating for Nanoparticles in Vivo
Liu, X., Cao, J., Li, H., Li, J., Jin, Q., Ren, K., & Ji, J. (2013) · ACS Nano · doi:10.1021/nn404117j · Cited by 667
Nanomaterial-based blood-brain-barrier (BBB) crossing strategies
Xie, J., Shen, Z., Anraku, Y., Kataoka, K., & Chen, X. (2019) · Biomaterials · doi:10.1016/j.biomaterials.2019.119491 · Cited by 604
Hersh, A. M., Alomari, S., & Tyler, B. M. (2022) · International Journal of Molecular Sciences · doi:10.3390/ijms23084153 · Cited by 478
Metadata
- Authors
- Qiao, R., Jia, Q., Hüwel, S., Xia, R., Liu, T., Gao, F., Galla, H.-J., & Gao, M.
- Venue
- ACS Nano
- Publisher
- American Chemical Society (ACS)
- Published
- 2012-03-29
- Volume
- 6
- Issue
- 4
- Pages
- 3304-3310
- ISSN
- 1936-0851 (ISSN-L)
- 1936-086X
- OpenAlex
- W1978507584
- Cited by
- 326
- References
- 4
- FWCI
- 11.40
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.