The DOI matches its Crossref record; 4 of the 4 references it cites were found in a registry or an index.
Toward Single-DNA Electrochemical Biosensing by Graphene Nanowalls
Abstract
Graphene oxide nanowalls with extremely sharp edges and preferred vertical orientation were deposited on a graphite electrode by using electrophoretic deposition in an Mg(2+)-GO electrolyte. Using differential pulse voltammetry (DPV), reduced graphene nanowalls (RGNWs) were applied for the first time, in developing an ultra-high-resolution electrochemical biosensor for detection of the four bases of DNA (G, A, T, and C) by monitoring the oxidation signals of the individual nucleotide bases. The extremely enhanced electrochemical reactivity of the four free bases of DNA, single-stranded DNA, and double-stranded DNA (dsDNA) at the surface of the RGNW electrode was compared to electrochemical performances of reduced graphene nanosheet (RGNS), graphite, and glassy carbon electrodes. By increasing the number of DPVs up to 100 scans, the RGNW electrode exhibited an excellent stability with only 15% variation in the oxidation signals, while for the RGNS electrode no detectable signals relating to T and C of 0.1 μM dsDNA were observed. The linear dynamic detection range of the RGNW electrode for dsDNA was checked in the wide range of 0.1 fM to 10 mM, while for the RGNS electrode, it was from 2.0 pM to <10 mM. The lower limits of dsDNA detection of the RGNW and RGNS electrodes were estimated as 9.4 zM (∼5 dsDNA/mL) and 5.4 fM, respectively. The RGNWs were efficient in label-free detection of single nucleotide polymorphisms of 20 zM oligonucleotides (∼10 DNA/mL) having a specific sequence. Therefore, the RGNWs can effectively contribute to the development of ultra-high-sensitive electrochemical biosensors with single-DNA resolutions.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Two-dimensional gas of massless Dirac fermions in graphene
Novoselov, K. S., Geim, A. K., Morozov, S. V., Jiang, D., Katsnelson, M. I., Grigorieva, I. V., Dubonos, S. V., & Firsov, A. A. (2005) · Nature · doi:10.1038/nature04233 · Cited by 21,611
Experimental observation of the quantum Hall effect and Berry's phase in graphene
Zhang, Y., Tan, Y.-W., Stormer, H. L., & Kim, P. (2005) · Nature · doi:10.1038/nature04235 · Cited by 13,435
Importance of the Debye Screening Length on Nanowire Field Effect Transistor Sensors
Stern, E., Wagner, R., Sigworth, F. J., Breaker, R., Fahmy, T. M., & Reed, M. A. (2007) · Nano Letters · doi:10.1021/nl071792z · Cited by 806
Zhang, J., Song, S., Zhang, L., Wang, L., Wu, H., Pan, D., & Fan, C. (2006) · Journal of the American Chemical Society · doi:10.1021/ja061521a · Cited by 424
Cited by
Electrochemistry of Graphene and Related Materials
Ambrosi, A., Chua, C. K., Bonanni, A., & Pumera, M. (2014) · Chemical Reviews · doi:10.1021/cr500023c · Cited by 1,208
Electrically-Transduced Chemical Sensors Based on Two-Dimensional Nanomaterials
Meng, Z., Stolz, R. M., Mendecki, L., & Mirica, K. A. (2019) · Chemical Reviews · doi:10.1021/acs.chemrev.8b00311 · Cited by 773
Graphene-Based Electrochemical Sensors
Wu, S., He, Q., Tan, C., Wang, Y., & Zhang, H. (2013) · Small · doi:10.1002/smll.201202896 · Cited by 628
Chen, P., Shen, X., Zhao, S., Liu, Z., Zhu, Q., Zhu, T., Zhang, S., Li, Y., Mao, L., & Sun, J. (2021) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2021.113143 · Cited by 5
Metadata
- Authors
- Akhavan, O., Ghaderi, E., & Rahighi, R.
- Venue
- ACS Nano
- Publisher
- American Chemical Society (ACS)
- Published
- 2012-03-14
- Volume
- 6
- Issue
- 4
- Pages
- 2904-2916
- ISSN
- 1936-0851 (ISSN-L)
- 1936-086X
- OpenAlex
- W2324756273
- Cited by
- 514
- References
- 4
- FWCI
- 34.59
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Toward Single-DNA Electrochemical Biosensing by Graphene Nanowalls. https://app.cochat.ai/papers/10.1021/nn300261t
- The paper
- Akhavan, O., Ghaderi, E., & Rahighi, R. (2012). Toward Single-DNA Electrochemical Biosensing by Graphene Nanowalls. ACS Nano. https://doi.org/10.1021/nn300261t
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.