The DOI matches its Crossref record.
Ultra-High Vacuum Scanning Thermal Microscopy for Nanometer Resolution Quantitative Thermometry
Abstract
Understanding energy dissipation at the nanoscale requires the ability to probe temperature fields with nanometer resolution. Here, we describe an ultra-high vacuum (UHV)-based scanning thermal microscope (SThM) technique that is capable of quantitatively mapping temperature fields with ∼15 mK temperature resolution and ∼10 nm spatial resolution. In this technique, a custom fabricated atomic force microscope (AFM) cantilever, with a nanoscale Au-Cr thermocouple integrated into the tip of the probe, is used to measure temperature fields of surfaces. Operation in an UHV environment eliminates parasitic heat transport between the tip and the sample enabling quantitative measurement of temperature fields on metal and dielectric surfaces with nanoscale resolution. We demonstrate the capabilities of this technique by directly imaging thermal fields in the vicinity of a 200 nm wide, self-heated, Pt line. Our measurements are in excellent agreement with computational results-unambiguously demonstrating the quantitative capabilities of the technique. UHV-SThM techniques will play an important role in the study of energy dissipation in nanometer-sized electronic and photonic devices and the study of phonon and electron transport at the nanoscale.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Nanoscale thermal transport. II. 2003–2012
Cahill, D. G., Braun, P. V., Chen, G., Clarke, D. R., Fan, S., Goodson, K. E., Keblinski, P., King, W. P., Mahan, G. D., Majumdar, A., et al. (2014) · Applied Physics Reviews · doi:10.1063/1.4832615 · Cited by 1,763
Principles of photothermal gas-phase heterogeneous CO2 catalysis
Ghoussoub, M., Xia, M., Duchesne, P. N., Segal, D., & Ozin, G. (2019) · Energy & Environmental Science · doi:10.1039/c8ee02790k · Cited by 531
Scanning thermal microscopy: A review
Gomès, S., Assy, A., & Chapuis, P.-O. (2015) · physica status solidi (a) · doi:10.1002/pssa.201400360 · Cited by 281
Nanoscale heat transfer – from computation to experiment
Luo, T., & Chen, G. (2013) · Physical Chemistry Chemical Physics · doi:10.1039/c2cp43771f · Cited by 273
High-performance flexible metal-on-silicon thermocouple
Assumpcao, D., Kumar, S., Narasimhan, V., Lee, J., & Choo, H. (2018) · Scientific Reports · doi:10.1038/s41598-018-32169-9 · Cited by 18
Metadata
- Authors
- Kim, K., Jeong, W., Lee, W., & Reddy, P.
- Venue
- ACS Nano
- Publisher
- American Chemical Society (ACS)
- Published
- 2012-05-02
- Volume
- 6
- Issue
- 5
- Pages
- 4248-4257
- ISSN
- 1936-0851 (ISSN-L)
- 1936-086X
- OpenAlex
- W2326528943
- Cited by
- 209
- References
- 0
- FWCI
- 6.95
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Ultra-High Vacuum Scanning Thermal Microscopy for Nanometer Resolution Quantitative Thermometry. https://app.cochat.ai/papers/10.1021/nn300774n
- The paper
- Kim, K., Jeong, W., Lee, W., & Reddy, P. (2012). Ultra-High Vacuum Scanning Thermal Microscopy for Nanometer Resolution Quantitative Thermometry. ACS Nano. https://doi.org/10.1021/nn300774n
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.