High-performance flexible metal-on-silicon thermocouple

Open access
Assumpcao, Daniel, Kumar, Shailabh, Narasimhan, Vinayak, Lee, Jongho, Choo, Hyuck · 2018 · Scientific Reports

Abstract

We have demonstrated metal-on-silicon thermocouples with a noticeably high Seebeck coefficient and an excellent temperature-sensing resolution. Fabrication of the thermocouples involved only simple photolithography and metal-liftoff procedures on a silicon substrate. The experimentally measured Seebeck coefficient of our thermocouple was 9.17 × 10−4 V/°K, which is 30 times larger than those reported for standard metal thin-film thermocouples and comparable to the values of alloy-based thin-film thermocouples that require sophisticated and costly fabrication processes. The temperature-voltage measurements between 20 to 80 °C were highly linear with a linearity coefficient of 1, and the experimentally demonstrated temperature-sensing resolution was 0.01 °K which could be further improved up to a theoretical limit of 0.00055 °K. Finally, we applied this approach to demonstrate a flexible metal-on-silicon thermocouple with enhanced thermal sensitivity. The outstanding performance of our thermocouple combined with an extremely thin profile, bending flexibility, and simple, highly-compatible fabrication will proliferate its use in diverse applications such as micro-/nanoscale biometrics, energy management, and nanoscale thermography.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1038/s41598-018-32169-9

Cites

46 of 46 references verified0 citation errors · 0 not checkable

Statistics

Figures

Figure 1 (a) Overview of the thermocouple structure. The thermally generated voltage (Vth) is measured at the cold end. The chrome strip forms a Schottky barrier and stays electrically isolated from the silicon substrate except at the hot point where the rectangular nickel pad forms a conductive ohmic contact and connects the chrome arm electrically to the silicon substrate only at the hot point, forming the chrome-silicon junction, resulting in a chrome-on-silicon thermocouple that makes the excellent use of the silicon’s large Seebeck coefficient while keeping the fabrication process simple. (b) Overall schematic of the thermocouple with the involved current path drawn on it. The colored arrows indicate the current path. (c) Equivalent resistive circuit for the chrome-on-silicon thermocouple in (b) to study their effects on the final Seebeck coefficient. The colored arrows indicate the current paths and the voltage measured between the points is a weighted average of the voltage change on each path. The blue arrow corresponds to the ideal current path leading to the highest output voltage consisting of the sum of the two Seebeck voltages. The red arrow corresponds to the very lossy current path leading to no voltage output (RCr: the resistance of the Cr arm; RSi: the resistance of the silicon between the measurement point and the pad; RCr-Si: the isolation resistance of the Schottky barrier between the Cr arm and the silicon; RCr-Ni-Si: the resistance of the Ni ohmic contact pad between the chromium and silicon arm; Vout: the output voltage measured at the pads; VCr: the Seebeck voltage contributed by the chromium arm; and VSi: the Seebeck voltage contributed by the silicon).
Figure 1 (a) Overview of the thermocouple structure. The thermally generated voltage (Vth) is measured at the cold end. The chrome strip forms a Schottky barrier and stays electrically isolated from the silicon substrate except at the hot point where the rectangular nickel pad forms a conductive ohmic contact and connects the chrome arm electrically to the silicon substrate only at the hot point, forming the chrome-silicon junction, resulting in a chrome-on-silicon thermocouple that makes the excellent use of the silicon’s large Seebeck coefficient while keeping the fabrication process simple. (b) Overall schematic of the thermocouple with the involved current path drawn on it. The colored arrows indicate the current path. (c) Equivalent resistive circuit for the chrome-on-silicon thermocouple in (b) to study their effects on the final Seebeck coefficient. The colored arrows indicate the current paths and the voltage measured between the points is a weighted average of the voltage change on each path. The blue arrow corresponds to the ideal current path leading to the highest output voltage consisting of the sum of the two Seebeck voltages. The red arrow corresponds to the very lossy current path leading to no voltage output (RCr: the resistance of the Cr arm; RSi: the resistance of the silicon between the measurement point and the pad; RCr-Si: the isolation resistance of the Schottky barrier between the Cr arm and the silicon; RCr-Ni-Si: the resistance of the Ni ohmic contact pad between the chromium and silicon arm; Vout: the output voltage measured at the pads; VCr: the Seebeck voltage contributed by the chromium arm; and VSi: the Seebeck voltage contributed by the silicon).CC BY · PubMed Central
Figure 2 (a) Diagram of a thermocouple unit cell which measures the temperature between its hot point (top of the diagram) and the cold end (bottom of the cell). The Cr metal arm is in brown, the Ni ohmic contact in silver, and the silicon substrate in black. In our simulation and analysis, we assume the unit cell has a size of X by X. (b) The effective Seebeck coefficient versus the characteristic size (x): the Seebeck coefficient goes down only when the size increases approximately above one meter and remains high and constant for micro scale measurements. (c) Schematic of two thermocouples adjacent to each other on a shared silicon substrate with individual current paths. The blue path corresponds to the ideal current path leading to no cross coupling and voltage loss. The red path corresponds to the lossy path through which no thermal voltage is produced. The green arrow indicates one possible cross coupling path where current goes from one Cr strip to the other Cr strip through two Schottky barriers. The brown arrow shows the other cross coupling path where current goes from one Ni hot point to the other through the Si substrate. (d) Equivalent circuit model for the two devices shown in (c). Rdist is an additional resistance that exists between the two points. (e) Cross-coupling (%) between the two hot points as a function of physical separation: the measurements represent the percent increase in temperature measured at one cold end caused by the increase of temperature at the hot point of the other device due to electrical crosstalk between them. The magnitude of the coupling remains small and relatively constant (<0.7%) below 1-mm separation. (f) Cross-coupling versus the unit size: the cross coupling remains relatively constant and negligible around 1×10−5% as the device size is decreased, suggesting that the cross coupling does not limit the device miniaturization.
Figure 2 (a) Diagram of a thermocouple unit cell which measures the temperature between its hot point (top of the diagram) and the cold end (bottom of the cell). The Cr metal arm is in brown, the Ni ohmic contact in silver, and the silicon substrate in black. In our simulation and analysis, we assume the unit cell has a size of X by X. (b) The effective Seebeck coefficient versus the characteristic size (x): the Seebeck coefficient goes down only when the size increases approximately above one meter and remains high and constant for micro scale measurements. (c) Schematic of two thermocouples adjacent to each other on a shared silicon substrate with individual current paths. The blue path corresponds to the ideal current path leading to no cross coupling and voltage loss. The red path corresponds to the lossy path through which no thermal voltage is produced. The green arrow indicates one possible cross coupling path where current goes from one Cr strip to the other Cr strip through two Schottky barriers. The brown arrow shows the other cross coupling path where current goes from one Ni hot point to the other through the Si substrate. (d) Equivalent circuit model for the two devices shown in (c). Rdist is an additional resistance that exists between the two points. (e) Cross-coupling (%) between the two hot points as a function of physical separation: the measurements represent the percent increase in temperature measured at one cold end caused by the increase of temperature at the hot point of the other device due to electrical crosstalk between them. The magnitude of the coupling remains small and relatively constant (<0.7%) below 1-mm separation. (f) Cross-coupling versus the unit size: the cross coupling remains relatively constant and negligible around 1×10−5% as the device size is decreased, suggesting that the cross coupling does not limit the device miniaturization.CC BY · PubMed Central
Figure 3 Fabrication of chrome-silicon thermocouples on a silicon wafer. (a) Start with a blank silicon wafer (dark grey in the drawing). (b) Deposit thin film of nickel (100 nm, silver in the drawing) on the wafer followed by liftoff patterning. (c) Deposit and pattern chromium (100 nm, brown in the drawing) on the wafer using liftoff. (d) Optical microscope image of an a fabricated 3 × 3 array of thermocouples with nickel patches of different shapes at the hot points. (e) A close-up optical microscope image of a hot point: the lighter, horizontal bar is made of nickel.
Figure 3 Fabrication of chrome-silicon thermocouples on a silicon wafer. (a) Start with a blank silicon wafer (dark grey in the drawing). (b) Deposit thin film of nickel (100 nm, silver in the drawing) on the wafer followed by liftoff patterning. (c) Deposit and pattern chromium (100 nm, brown in the drawing) on the wafer using liftoff. (d) Optical microscope image of an a fabricated 3 × 3 array of thermocouples with nickel patches of different shapes at the hot points. (e) A close-up optical microscope image of a hot point: the lighter, horizontal bar is made of nickel.CC BY · PubMed Central
Figure 4 Performance of the chrome-on-silicon thermocouple. (a) Thermal voltage vs temperature measurements were made with the cold end constantly held at 20 °C. The device produces linear output between 20 °C and 80 °C. (b) Noise measurements - voltage output of the thermocouple over time at a constant temperature. This helps us find the noise floor of the device. The standard deviation of the noise measurements was 0.143 µV.
Figure 4 Performance of the chrome-on-silicon thermocouple. (a) Thermal voltage vs temperature measurements were made with the cold end constantly held at 20 °C. The device produces linear output between 20 °C and 80 °C. (b) Noise measurements - voltage output of the thermocouple over time at a constant temperature. This helps us find the noise floor of the device. The standard deviation of the noise measurements was 0.143 µV.CC BY · PubMed Central
Figure 5 Temperature step measurements. The temperature was raised and lowered by (a) 0.05 °C, (b) 0.02 °C, and (c) 0.01 °C using a hot plate. The reference temperature was obtained using the built-in thermistor of the hot plate (left, in blue) while the voltage was measured on the device (right, in red). The measurements show clear step-shift in voltage level down to the temperature change of 0.01 °C, supporting that 0.01 °C sensitivity can be achieved with this device.
Figure 5 Temperature step measurements. The temperature was raised and lowered by (a) 0.05 °C, (b) 0.02 °C, and (c) 0.01 °C using a hot plate. The reference temperature was obtained using the built-in thermistor of the hot plate (left, in blue) while the voltage was measured on the device (right, in red). The measurements show clear step-shift in voltage level down to the temperature change of 0.01 °C, supporting that 0.01 °C sensitivity can be achieved with this device.CC BY · PubMed Central
Figure 6 Flexible chrome-on-silicon thermocouple arrays with a high Seebeck coefficient fabricated on a 50 µm-thick double-side-polished silicon wafer. (a) In bending testing, the flexible thermocouple array achieved a bending radius of 1.51 cm and a curvature angle of 64.98°. (b) Seebeck measurements of the flexible thermocouple array made on a flexible thin wafer – the measurements are highly linear with a high Seebeck coefficient.
Figure 6 Flexible chrome-on-silicon thermocouple arrays with a high Seebeck coefficient fabricated on a 50 µm-thick double-side-polished silicon wafer. (a) In bending testing, the flexible thermocouple array achieved a bending radius of 1.51 cm and a curvature angle of 64.98°. (b) Seebeck measurements of the flexible thermocouple array made on a flexible thin wafer – the measurements are highly linear with a high Seebeck coefficient.CC BY · PubMed Central

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 46 references

Cited by

See all 18

Metadata

Authors
Assumpcao, D., Kumar, S., Narasimhan, V., Lee, J., & Choo, H.
Affiliations
  • California Institute of Technology (US)
  • Gwangju Institute of Science and Technology (KR)
Corresponding author
Choo, Hyuck
Venue
Scientific Reports
Published
2018-09-13
Volume
8
Issue
1
Pages
13725-13725
ISSN
2045-2322 (ISSN-L)
OpenAlex
W2891763711
Cited by
18
References
46
Citations by year
2026: 2 · 2025: 1 · 2024: 7 · 2023: 2 · 2022: 1 · 2021: 4 · 2020: 1
FWCI
0.47
Type
journal article
Language
en
Open access
Licence
Locations
  • Scientific Reports (publishedVersion, cc-by)
  • Europe PMC (PubMed Central) (publishedVersion, cc-by)
  • PubMed Central (publishedVersion, cc-by)
  • PubMed (publishedVersion)
  • CaltechAUTHORS (California Institute of Technology) (submittedVersion, cc-by)
  • DOAJ (DOAJ: Directory of Open Access Journals) (submittedVersion, cc-by-sa)
Funders
  • California Institute of Technology
  • Heritage Medical Research Institute
Topics
  • Physical Sciences › Materials Science › Materials Chemistry › Advanced Thermoelectric Materials and Devices
  • Physical Sciences › Physics and Astronomy › Instrumentation › Advanced Sensor Technologies Research
  • Physical Sciences › Engineering › Electrical and Electronic Engineering › Advanced MEMS and NEMS Technologies
Keywords
Seebeck coefficient, thin film thermocouples, photolithography, thermal sensitivity, biometrics

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: High-performance flexible metal-on-silicon thermocouple. https://app.cochat.ai/papers/10.1038/s41598-018-32169-9
The paper
Assumpcao, D., Kumar, S., Narasimhan, V., Lee, J., & Choo, H. (2018). High-performance flexible metal-on-silicon thermocouple. Scientific Reports. https://doi.org/10.1038/s41598-018-32169-9

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.