The DOI matches its Crossref record; 4 of the 4 references it cites were found in a registry or an index.
Highly Sensitive Glucose Sensor Based on Pt Nanoparticle/Polyaniline Hydrogel Heterostructures
Abstract
Glucose enzyme biosensors have been shown useful for a range of applications from medical diagnosis, bioprocess monitoring, to beverage industry and environmental monitoring. We present here a highly sensitive glucose enzyme sensor based on Pt nanoparticles (PtNPs)-polyaniline (PAni) hydrogel heterostructures. High-density PtNPs were homogeneously loaded onto the three-dimensional (3D) nanostructured matrix of the PAni hydrogel. The PtNP/PAni hydrogel heterostructure-based glucose sensor synergizes the advantages of both the conducting hydrogel and the nanoparticle catalyst. The porous structure of the PAni hydrogel favored the high density immobilization of the enzyme and the penetration of water-soluble molecules, which helped efficiently catalyze the oxidation of glucose. In addition, the PtNPs catalyzed the decomposition of hydrogen peroxide that was generated during the enzymatic reaction. The transferred charges from these electrochemical processes were efficiently collected by the highly conducting PtNP/PAni hydrogel heterostructures. The glucose enzyme sensor based on this heterostructure exhibited unprecedented sensitivity, as high as 96.1 μA·mM(-1)·cm(-2), with a response time as fast as 3 s, a linear range of 0.01 to 8 mM, and a low detection limit of 0.7 μM.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Electrochemical Glucose Biosensors
Wang, J. (2008) · Chemical Reviews · doi:10.1021/cr068123a · Cited by 3,498
Electrochemical Glucose Sensors and Their Applications in Diabetes Management
Heller, A., & Feldman, B. (2008) · Chemical Reviews · doi:10.1021/cr068069y · Cited by 1,707
Hierarchical nanostructured conducting polymer hydrogel with high electrochemical activity
Pan, L., Yu, G., Zhai, D., Lee, H. R., Zhao, W., Liu, N., Wang, H., Tee, B. C.-K., Shi, Y., Cui, Y., et al. (2012) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.1202636109 · Cited by 1,216
Self-citationPhotoemission from mass-selected monodispersed Pt clusters
Eberhardt, W., Fayet, P., Cox, D. M., Fu, Z., Kaldor, A., Sherwood, R., & Sondericker, D. (1990) · Physical Review Letters · doi:10.1103/physrevlett.64.780 · Cited by 284
Cited by
Electrochemical Sensors and Biosensors Based on Nanomaterials and Nanostructures
Zhu, C., Yang, G., Li, H., Du, D., & Lin, Y. (2015) · Analytical Chemistry · doi:10.1021/ac5039863 · Cited by 1,741
Liu, X., Liu, J., Lin, S., & Zhao, X. (2020) · Materials Today · doi:10.1016/j.mattod.2019.12.026 · Cited by 1,023
Zhu, C., Du, D., Eychmüller, A., & Lin, Y. (2015) · Chemical Reviews · doi:10.1021/acs.chemrev.5b00255 · Cited by 672
El-Husseiny, H. M., Mady, E. A., Hamabe, L., Abugomaa, A., Shimada, K., Yoshida, T., Tanaka, T., Yokoi, A., Elbadawy, M., & Tanaka, R. (2022) · Materials Today Bio · doi:10.1016/j.mtbio.2021.100186 · Cited by 533
Hydrogel Based Sensors for Biomedical Applications: An Updated Review
Tavakoli, J., & Tang, Y. (2017) · Polymers · doi:10.3390/polym9080364 · Cited by 434
Metadata
- Authors
- Zhai, D., Liu, B., Shi, Y., Pan, L., Wang, Y., Li, W., Zhang, R., & Yu, G.
- Venue
- ACS Nano
- Publisher
- American Chemical Society (ACS)
- Published
- 2013-03-14
- Volume
- 7
- Issue
- 4
- Pages
- 3540-3546
- ISSN
- 1936-0851 (ISSN-L)
- 1936-086X
- OpenAlex
- W2031449366
- Cited by
- 814
- References
- 4
- FWCI
- 42.14
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.