The DOI matches its Crossref record; 4 of the 4 references it cites were found in a registry or an index.
Ultrarapid Generation of Femtoliter Microfluidic Droplets for Single-Molecule-Counting Immunoassays
Open accessAbstract
We report a microfluidic droplet-based approach enabling the measurement of chemical reactions of individual enzyme molecules and its application to a single-molecule-counting immunoassay. A microfluidic device is used to generate and manipulate <10 fL droplets at rates of up to 1.3 × 10(6) per second, about 2 orders of magnitude faster than has previously been reported. The femtodroplets produced with this device can be used to encapsulate single biomolecular complexes tagged with a reporter enzyme; their small volume enables the fluorescent product of a single enzyme molecule to be detected within 10 min of on-chip incubation. Our prototype system is validated by detection of a biomarker for prostate cancer in buffer, down to a concentration of 46 fM. This work demonstrates a highly flexible and sensitive diagnostic platform that exploits extremely high-speed generation of monodisperse femtoliter droplets for the counting of individual analyte molecules.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
The origins and the future of microfluidics
Whitesides, G. M. (2006) · Nature · doi:10.1038/nature05058 · Cited by 9,687
Alzheimer’s Disease: The Challenge of the Second Century
Holtzman, D. M., Morris, J. C., & Goate, A. M. (2011) · Science Translational Medicine · doi:10.1126/scitranslmed.3002369 · Cited by 1,424
Stochastic protein expression in individual cells at the single molecule level
Cai, L., Friedman, N., & Xie, X. S. (2006) · Nature · doi:10.1038/nature04599 · Cited by 1,145
Duff, B. R. L., & Faber, R. J. (2011) · Journal of Advertising · doi:10.2753/joa0091-3367400204 · Cited by 137
Cited by
Emerging Droplet Microfluidics
Shang, L., Cheng, Y., & Zhao, Y. (2017) · Chemical Reviews · doi:10.1021/acs.chemrev.6b00848 · Cited by 1,584
Passive and active droplet generation with microfluidics: a review
Zhu, P., & Wang, L. (2017) · Lab on a Chip · doi:10.1039/c6lc01018k · Cited by 1,238
Single-Exosome-Counting Immunoassays for Cancer Diagnostics
Liu, C., Xu, X., Li, B., Situ, B., Pan, W., Hu, Y., An, T., Yao, S., & Zheng, L. (2018) · Nano Letters · doi:10.1021/acs.nanolett.8b01184 · Cited by 406
Currin, A., Swainston, N., Day, P. J., & Kell, D. B. (2015) · Chemical Society Reviews · doi:10.1039/c4cs00351a · Cited by 388
Controlled droplet microfluidic systems for multistep chemical and biological assays
Kaminski, T. S., & Garstecki, P. (2017) · Chemical Society Reviews · doi:10.1039/c5cs00717h · Cited by 299
Metadata
- Authors
- Shim, J.-U., Ranasinghe, R. T., Smith, C. A., Ibrahim, S. M., Hollfelder, F., Huck, W. T. S., Klenerman, D., & Abell, C.
- Venue
- ACS Nano
- Publisher
- American Chemical Society (ACS)
- Published
- 2013-07-08
- Volume
- 7
- Issue
- 7
- Pages
- 5955-5964
- ISSN
- 1936-0851 (ISSN-L)
- 1936-086X
- OpenAlex
- W2080681593
- Cited by
- 218
- References
- 4
- FWCI
- 8.15
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Ultrarapid Generation of Femtoliter Microfluidic Droplets for Single-Molecule-Counting Immunoassays. https://app.cochat.ai/papers/10.1021/nn401661d
- The paper
- Shim, J.-U., Ranasinghe, R. T., Smith, C. A., Ibrahim, S. M., Hollfelder, F., Huck, W. T. S., Klenerman, D., & Abell, C. (2013). Ultrarapid Generation of Femtoliter Microfluidic Droplets for Single-Molecule-Counting Immunoassays. ACS Nano. https://doi.org/10.1021/nn401661d
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.