The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Bioinspired Graphene Nanopores with Voltage-Tunable Ion Selectivity for Na+ and K+
Abstract
Biological protein channels have many remarkable properties such as gating, high permeability, and selectivity, which have motivated researchers to mimic their functions for practical applications. Herein, using molecular dynamics simulations, we design bioinspired nanopores in graphene sheets that can discriminate between Na(+) and K(+), two ions with very similar properties. The simulation results show that, under transmembrane voltage bias, a nanopore containing four carbonyl groups to mimic the selectivity filter of the KcsA K(+) channel preferentially conducts K(+) over Na(+). A nanopore functionalized by four negatively charged carboxylate groups to mimic the selectivity filter of the NavAb Na(+) channel selectively binds Na(+) but transports K(+) over Na(+). Surprisingly, the ion selectivity of the smaller diameter pore containing three carboxylate groups can be tuned by changing the magnitude of the applied voltage bias. Under lower voltage bias, it transports ions in a single-file manner and exhibits Na(+) selectivity, dictated by the knock-on ion conduction and selective blockage by Na(+). Under higher voltage bias, the nanopore is K(+)-selective, as the blockage by Na(+) is destabilized and the stronger affinity for carboxylate groups slows the passage of Na(+) compared with K(+). The computational design of biomimetic ion-selective nanopores helps to understand the mechanisms of selectivity in biological ion channels and may also lead to a wide range of potential applications such as sensitive ion sensors, nanofiltration membranes for Na(+)/K(+) separation, and voltage-tunable nanofluidic devices.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Cation selective glass electrodes and their mode of operation
Eisenman, G. (1962) · Biophysical Journal · doi:10.1016/s0006-3495(62)86959-8 · Cited by 852
Cited by
Wang, L., Boutilier, M. S. H., Kidambi, P. R., Jang, D., Hadjiconstantinou, N. G., & Karnik, R. (2017) · Nature Nanotechnology · doi:10.1038/nnano.2017.72 · Cited by 824
Sun, P., Wang, K., & Zhu, H. (2016) · Advanced Materials · doi:10.1002/adma.201502595 · Cited by 668
Efficient metal ion sieving in rectifying subnanochannels enabled by metal–organic frameworks
Lu, J., Zhang, H., Hou, J., Li, X., Hu, X., Hu, Y., Easton, C. D., Li, Q., Sun, C., Thornton, A. W., et al. (2020) · Nature Materials · doi:10.1038/s41563-020-0634-7 · Cited by 565
Ion selectivity of graphene nanopores
Rollings, R. C., Kuan, A. T., & Golovchenko, J. A. (2016) · Nature Communications · doi:10.1038/ncomms11408 · Cited by 521
Graphene membranes for water desalination
Homaeigohar, S., & Elbahri, M. (2017) · NPG Asia Materials · doi:10.1038/am.2017.135 · Cited by 444
2D nanostructures for water purification: graphene and beyond
Dervin, S., Dionysiou, D. D., & Pillai, S. C. (2016) · Nanoscale · doi:10.1039/c6nr04508a · Cited by 398
Peng, H., & Zhao, Q. (2021) · Advanced Functional Materials · doi:10.1002/adfm.202009430 · Cited by 389
Nonthermal and reversible control of neuronal signaling and behavior by midinfrared stimulation
Liu, X., Qiao, Z., Chai, Y., Zhu, Z., Wu, K., Ji, W., Li, D., Xiao, Y., Mao, L., Chang, C., et al. (2021) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.2015685118 · Cited by 288
Transport mechanisms in nanopores and nanochannels: can we mimic nature?
Tagliazucchi, M., & Szleifer, I. (2015) · Materials Today · doi:10.1016/j.mattod.2014.10.020 · Cited by 269
Metadata
- Authors
- He, Z., Zhou, J., Lu, X., & Corry, B.
- Venue
- ACS Nano
- Publisher
- American Chemical Society (ACS)
- Published
- 2013-10-25
- Volume
- 7
- Issue
- 11
- Pages
- 10148-10157
- ISSN
- 1936-0851 (ISSN-L)
- 1936-086X
- OpenAlex
- W2054283887
- Cited by
- 249
- References
- 1
- FWCI
- 7.44
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.