Integrated Biodetection in a Nanofluidic Device
The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Abstract
The sensing of enzymatic processes in volumes at or below the scale of single cells is challenging but highly desirable in the study of biochemical processes. Here we demonstrate a nanofluidic device that combines an enzymatic recognition element and electrochemical signal transduction within a six-femtoliter volume. Our approach is based on localized immobilization of the enzyme tyrosinase in a microfabricated nanogap electrochemical transducer. The enzymatic reaction product quinone is localized in the confined space of a nanochannel in which efficient redox cycling also takes place. Thus, the sensor allows the sensitive detection of minute amounts of product molecules generated by the enzyme in real time. This method is ideally suited for the study of ultra-small-volume systems such as the contents of individual biological cells or organelles.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
The present and future role of microfluidics in biomedical research
Sackmann, E. K., Fulton, A. L., & Beebe, D. J. (2014) · Nature · doi:10.1038/nature13118 · Cited by 2,995
Ismaya, W. T., Rozeboom, H. J., Weijn, A., Mes, J. J., Fusetti, F., Wichers, H. J., & Dijkstra, B. W. (2011) · Biochemistry · doi:10.1021/bi200395t · Cited by 872
Cited by
Critical Knowledge Gaps in Mass Transport through Single-Digit Nanopores: A Review and Perspective
Faucher, S., Aluru, N., Bazant, M. Z., Blankschtein, D., Brozena, A. H., Cumings, J., Pedro de Souza, J., Elimelech, M., Epsztein, R., Fourkas, J. T., et al. (2019) · The Journal of Physical Chemistry C · doi:10.1021/acs.jpcc.9b02178 · Cited by 365
Dong, T., Matos Pires, N. M., Yang, Z., & Jiang, Z. (2023) · Advanced Science · doi:10.1002/advs.202205429 · Cited by 104
Vannoy, K. J., Ryabykh, A., Chapoval, A. I., & Dick, J. E. (2021) · The Analyst · doi:10.1039/d1an00230a · Cited by 26
Metadata
- Authors
- Rassaei, L., Mathwig, K., Kang, S., Heering, H. A., & Lemay, S. G.
- Venue
- ACS Nano
- Publisher
- American Chemical Society (ACS)
- Published
- 2014-08-08
- Volume
- 8
- Issue
- 8
- Pages
- 8278-8284
- ISSN
- 1936-0851 (ISSN-L)
- 1936-086X
- OpenAlex
- W2315156931
- Cited by
- 65
- References
- 2
- FWCI
- 5.13
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Integrated Biodetection in a Nanofluidic Device. https://app.cochat.ai/papers/10.1021/nn502678t
- The paper
- Rassaei, L., Mathwig, K., Kang, S., Heering, H. A., & Lemay, S. G. (2014). Integrated Biodetection in a Nanofluidic Device. ACS Nano. https://doi.org/10.1021/nn502678t
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.