Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 223

The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.

Label-Free, Electrical Detection of the SARS Virus N-Protein with Nanowire Biosensors Utilizing Antibody Mimics as Capture Probes

Open access
Ishikawa, Fumiaki N., Chang, Hsiao-Kang, Curreli, Marco, Liao, Hsiang-I, Olson, C. Anders, Chen, Po-Chiang, Zhang, Rui, Roberts, Richard W., Sun, Ren, Cote, Richard J., Thompson, Mark E., Zhou, Chongwu·2009·ACS Nano

Abstract

Antibody mimic proteins (AMPs) are polypeptides that bind to their target analytes with high affinity and specificity, just like conventional antibodies, but are much smaller in size (2-5 nm, less than 10 kDa). In this report, we describe the first application of AMP in the field of nanobiosensors. In(2)O(3) nanowire based biosensors have been configured with an AMP (Fibronectin, Fn) to detect nucleocapsid (N) protein, a biomarker for severe acute respiratory syndrome (SARS). Using these devices, N protein was detected at subnanomolar concentration in the presence of 44 microM bovine serum albumin as a background. Furthermore, the binding constant of the AMP to Fn was determined from the concentration dependence of the response of our biosensors.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1021/nn900086c

Cites

2 of 2 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 2 references

Cited by

Metadata

Authors
Ishikawa, F. N., Chang, H.-K., Curreli, M., Liao, H.-I., Olson, C. A., Chen, P.-C., Zhang, R., Roberts, R. W., Sun, R., Cote, R. J., Thompson, M. E., & Zhou, C.
Venue
ACS Nano
Published
2009-05-07
Volume
3
Issue
5
Pages
1219-1224
ISSN
  • 1936-0851 (ISSN-L)
  • 1936-086X
OpenAlex
W2095627673
Cited by
223
References
2
FWCI
13.46
Type
journal article
Language
en
Open access
green

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.