The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Label-Free, Electrical Detection of the SARS Virus N-Protein with Nanowire Biosensors Utilizing Antibody Mimics as Capture Probes
Open accessAbstract
Antibody mimic proteins (AMPs) are polypeptides that bind to their target analytes with high affinity and specificity, just like conventional antibodies, but are much smaller in size (2-5 nm, less than 10 kDa). In this report, we describe the first application of AMP in the field of nanobiosensors. In(2)O(3) nanowire based biosensors have been configured with an AMP (Fibronectin, Fn) to detect nucleocapsid (N) protein, a biomarker for severe acute respiratory syndrome (SARS). Using these devices, N protein was detected at subnanomolar concentration in the presence of 44 microM bovine serum albumin as a background. Furthermore, the binding constant of the AMP to Fn was determined from the concentration dependence of the response of our biosensors.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Label-free immunodetection with CMOS-compatible semiconducting nanowires
Stern, E., Klemic, J. F., Routenberg, D. A., Wyrembak, P. N., Turner-Evans, D. B., Hamilton, A. D., LaVan, D. A., Fahmy, T. M., & Reed, M. A. (2007) · Nature · doi:10.1038/nature05498 · Cited by 1,352
Importance of the Debye Screening Length on Nanowire Field Effect Transistor Sensors
Stern, E., Wagner, R., Sigworth, F. J., Breaker, R., Fahmy, T. M., & Reed, M. A. (2007) · Nano Letters · doi:10.1021/nl071792z · Cited by 806
Cited by
Electrical biosensors and the label free detection of protein disease biomarkers
Luo, X., & Davis, J. J. (2013) · Chemical Society Reviews · doi:10.1039/c3cs60077g · Cited by 460
Advances and challenges in biosensor-based diagnosis of infectious diseases
Sin, M. L., Mach, K. E., Wong, P. K., & Liao, J. C. (2014) · Expert Review of Molecular Diagnostics · doi:10.1586/14737159.2014.888313 · Cited by 435
Opportunities and Challenges for Biosensors and Nanoscale Analytical Tools for Pandemics: COVID-19
Bhalla, N., Pan, Y., Yang, Z., & Payam, A. F. (2020) · ACS Nano · doi:10.1021/acsnano.0c04421 · Cited by 385
Label-free biological and chemical sensors
Hunt, H. K., & Armani, A. M. (2010) · Nanoscale · doi:10.1039/c0nr00201a · Cited by 371
Recombinant Probes for Visualizing Endogenous Synaptic Proteins in Living Neurons
Gross, G. G., Junge, J. A., Mora, R. J., Kwon, H.-B., Olson, C. A., Takahashi, T. T., Liman, E. R., Ellis-Davies, G. C. R., McGee, A. W., Sabatini, B. L., et al. (2013) · Neuron · doi:10.1016/j.neuron.2013.04.017 · Cited by 357
Self-citation
Metadata
- Authors
- Ishikawa, F. N., Chang, H.-K., Curreli, M., Liao, H.-I., Olson, C. A., Chen, P.-C., Zhang, R., Roberts, R. W., Sun, R., Cote, R. J., Thompson, M. E., & Zhou, C.
- Venue
- ACS Nano
- Publisher
- American Chemical Society (ACS)
- Published
- 2009-05-07
- Volume
- 3
- Issue
- 5
- Pages
- 1219-1224
- ISSN
- 1936-0851 (ISSN-L)
- 1936-086X
- OpenAlex
- W2095627673
- Cited by
- 223
- References
- 2
- FWCI
- 13.46
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.