The DOI matches its Crossref record; 22 of the 22 references it cites were found in a registry or an index.
A Monostyryl-boradiazaindacene (BODIPY) Derivative as Colorimetric and Fluorescent Probe for Cyanide Ions
Open accessAbstract
We developed a novel boradiazaindacene derivative to detect cyanide ions in solution at micromolar concentrations. This structurally simple chemosensor displays a large decrease in emission intensity and a reversible color change from red to blue on contact with cyanide ions. Highly fluorescent polymeric films can be obtained by doping with the chemosensor. Such polymeric materials can be used for the sensing of the cyanide ions in polymer matrices.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Principles of Fluorescence Spectroscopy
Lakowicz, J. R. (1999) · Springer eBooks · doi:10.1007/978-1-4757-3061-6 · Cited by 26,947
Principles of Fluorescence Spectroscopy
(2006) · Springer eBooks · doi:10.1007/978-0-387-46312-4 · Cited by 19,339
The Handbook: A Guide to Fluorescent Probes and Labeling Technologies
Haugland, R. P. (2005) · Cited by 755
Rurack, K., Kollmannsberger, M., Resch-Genger, U., & Daub, J. (2000) · Journal of the American Chemical Society · doi:10.1021/ja992630a · Cited by 685
Gabe, Y., Urano, Y., Kikuchi, K., Kojima, H., & Nagano, T. (2004) · Journal of the American Chemical Society · doi:10.1021/ja037944j · Cited by 668
Luminescence Lifetime-Based Sensor for Cyanide and Related Anions
Anzenbacher, Tyson, D. S., Jursíková, K., & Castellano, F. N. (2002) · Journal of the American Chemical Society · doi:10.1021/ja0259180 · Cited by 460
Coskun, A., & Akkaya, E. U. (2005) · Journal of the American Chemical Society · doi:10.1021/ja052574f · Cited by 404
Self-citationBadugu, R., Lakowicz, J. R., & Geddes, C. D. (2005) · Journal of the American Chemical Society · doi:10.1021/ja044421i · Cited by 392
Neutral anion receptors: design and application
Antonisse, M. M. G., & Reinhoudt, D. N. (1998) · Chemical Communications · doi:10.1039/a707529d · Cited by 339
Topics in Fluorescence Spectroscopy: Probe Design and Chemical Sensing
(1994) · Springer eBooks · doi:10.1007/b112911 · Cited by 303
Anion recognition: synthetic receptors for anions and their application in sensors
Snowden, T. S., & Anslyn, E. V. (1999) · Current Opinion in Chemical Biology · doi:10.1016/s1367-5931(99)00034-4 · Cited by 291
Bis(2-pyridyl)-Substituted Boratriazaindacene as an NIR-Emitting Chemosensor for Hg(II)
Coskun, A., Yilmaz, M. D., & Akkaya, E. U. (2007) · Organic Letters · doi:10.1021/ol062867t · Cited by 244
Self-citationModulation of Boradiazaindacene Emission by Cation-Mediated Oxidative PET
Turfan, B., & Akkaya, E. U. (2002) · Organic Letters · doi:10.1021/ol026245t · Cited by 198
Self-citationDistyryl-boradiazaindacenes: facile synthesis of novel near IR emitting fluorophores
Dost, Z., Atilgan, S., & Akkaya, E. U. (2006) · Tetrahedron · doi:10.1016/j.tet.2006.06.082 · Cited by 197
Self-citationYilmaz, M. D., Bozdemir, O. A., & Akkaya, E. U. (2006) · Organic Letters · doi:10.1021/ol061110z · Cited by 181
Self-citationDetermination of Cyanide in Whole Blood by Capillary Gas Chromatography with Cryogenic Oven Trapping
Ishii, A., Seno, H., Watanabe-Suzuki, K., Suzuki, O., & Kumazawa, T. (1998) · Analytical Chemistry · doi:10.1021/ac980498b · Cited by 163
Cation Sensors Based on Terpyridine‐Functionalized Boradiazaindacene
Goze, C., Ulrich, G., Charbonnière, L. J., Césario, M., Prangé, T., & Ziessel, R. F. (2003) · Chemistry - A European Journal · doi:10.1002/chem.200305084 · Cited by 141
Convenient Synthesis of Green Diisoindolodithienylpyrromethene−Dialkynyl Borane Dyes
Goeb, S., & Ziessel, R. (2007) · Organic Letters · doi:10.1021/ol0627404 · Cited by 115
Unusual Fluorescent Monomeric and Dimeric Dialkynyl Dipyrromethene−Borane Complexes
Goze, C., Ulrich, G., & Ziessel, R. (2006) · Organic Letters · doi:10.1021/ol061601j · Cited by 101
Şaki, N., Tarik, D., & Akkaya, E. U. (2005) · Tetrahedron · doi:10.1016/j.tet.2005.12.021 · Cited by 100
Self-citationPotential for Error when Assessing Blood Cyanide Concentrations in Fire Victims
Moriya, F., & Hashimoto, Y. (2001) · Journal of Forensic Sciences · doi:10.1520/jfs15165j · Cited by 76
Zepik (2001) · doi:10.1002/1521-3773(20010105)40:1
Cited by
Fluorescent indicators based on BODIPY
Boens, N., Leen, V., & Dehaen, W. (2012) · Chem. Soc. Rev. · doi:10.1039/c1cs15132k · Cited by 2,262
Luminescent Chemodosimeters for Bioimaging
Yang, Y., Zhao, Q., Feng, W., & Li, F. (2013) · Chemical Reviews · doi:10.1021/cr2004103 · Cited by 2,236
BODIPY dyes in photodynamic therapy
Kamkaew, A., Lim, S. H., Lee, H. B., Kiew, L. V., Chung, L. Y., & Burgess, K. (2013) · Chem. Soc. Rev. · doi:10.1039/c2cs35216h · Cited by 2,104
Applications of Supramolecular Anion Recognition
Busschaert, N., Caltagirone, C., Van Rossom, W., & Gale, P. A. (2015) · Chemical Reviews · doi:10.1021/acs.chemrev.5b00099 · Cited by 1,249
Sensors for the optical detection ofcyanide ion
Xu, Z., Chen, X., Kim, H. N., & Yoon, J. (2010) · Chem. Soc. Rev. · doi:10.1039/b907368j · Cited by 1,121
Metadata
- Authors
- Ekmekci, Z., Yilmaz, M. D., & Akkaya, E. U.
- Venue
- Organic Letters
- Publisher
- American Chemical Society (ACS)
- Published
- 2008-01-09
- Volume
- 10
- Issue
- 3
- Pages
- 461-464
- ISSN
- 1523-7052 (ISSN-L)
- 1523-7060
- OpenAlex
- W2003908111
- Cited by
- 302
- References
- 22
- FWCI
- 13.31
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.