Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 164

The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.

Band-Target Entropy Minimization (BTEM): An Advanced Method for Recovering Unknown Pure Component Spectra. Application to the FTIR Spectra of Unstable Organometallic Mixtures

Chew, Wee, Widjaja, Effendi, Garland, Marc·2002·Organometallics

Abstract

A newly developed band-target entropy minimization (BTEM) algorithm was tested on experimental FTIR data of Rh 4 (CO) 12 /Rh 6 (CO) 16 mixtures in order to recover the pure component spectra of the constituent complexes. Bands in the nonoverlapping bridging carbonyl region as well as bands in the highly overlapping terminal carbonyl region were targeted for retention. The bands are identified in the vector-space decomposition of the observations, a crucial first step in untangling the superposition of the pure component spectra. In both cases, the targeted band was retained, and exceptionally accurate whole spectral estimates of Rh 4 (CO) 12 and Rh 6 (CO) 16 were obtained. Due to the constructs used in BTEM, enhanced signal-to-noise characteristics result, and spectral nonlinearities arising from changing band positions and changing band shapes are essentially eliminated. For the experimentalist, the utility of BTEM arises from its direct one-spectrum-at-a-time spectral reconstruction approach which is guided by the choice of the targeted region. As such, BTEM appears particularly applicable to spectroscopy possessing highly localized features: i.e., FTIR, Raman, etc. The BTEM algorithm is so useful that the spectral pattern from the minute presence of suspended particles of Rh 6 (CO) 16 could be reconstructed. Indeed, the integrated absorbance of Rh 4 (CO) 12, Rh 6 (CO) 16, and Rh 6 (CO) 16 solids account for only ca. 0.3, 0.09, and 0.04% of the experimental observations. The new BTEM algorithm was compared to other algorithms such as SIMPLISMA, IPCA, and OPA-ALS. The latter either fail with the present data set or are unable to produce reconstructed spectra of similar quality to BTEM. This new algorithm holds considerable promise for the analysis of in-situ spectroscopic reaction data such as those arising in complex organometallic and organic syntheses, where absolutely no a priori information about the constituents/intermediates is available.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1021/om0108752

Cites

1 of 1 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Cited by

See all 164

Metadata

Authors
Chew, W., Widjaja, E., & Garland, M.
Venue
Organometallics
Published
2002-04-22
Volume
21
Issue
9
Pages
1982-1990
ISSN
  • 0276-7333 (ISSN-L)
  • 1520-6041
OpenAlex
W2074309354
Cited by
164
References
1
FWCI
8.27
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.