Gas-Phase Rearrangements Do Not Affect Site Localization Reliability in Phosphoproteomics Data Sets
Open accessThe DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.
Abstract
Intramolecular transfer of phosphate during collision-induced dissociation (CID) in ion-trap mass spectrometers has recently been described. Because phosphorylation events are assigned to discrete serine, threonine, and tyrosine residues based on the presence of site-determining ions in MS/MS spectra, phosphate transfer may invalidate or confound site localization in published large-scale phosphorylation data sets. Here, we present evidence for the occurrence of this phenomenon using synthetic phosphopeptide libraries, specifically for doubly charged species. We found, however, that the extent of the transfer reaction was insufficient to cause localization of phosphorylation sites to incorrect residues. We further compared CID to electron-transfer dissociation (ETD) for site localization using synthetic libraries and a large-scale yeast phosphoproteome experiment. The agreement in site localization was >99.5 and 93%, respectively, suggesting that ETD-based site localization is no more reliable than CID. We conclude that intramolecular phosphate transfer does not affect the reliability of current or past phosphorylation data sets.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
A quantitative atlas of mitotic phosphorylation
Dephoure, N., Zhou, C., Villén, J., Beausoleil, S. A., Bakalarski, C. E., Elledge, S. J., & Gygi, S. P. (2008) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0805139105 · Cited by 1,608
Self-citationBeausoleil, S. A., Villén, J., Gerber, S. A., Rush, J., & Gygi, S. P. (2006) · Nature Biotechnology · doi:10.1038/nbt1240 · Cited by 1,577
Self-citationProtein identification using sequential ion/ion reactions and tandem mass spectrometry
Coon, J. J., Ueberheide, B., Syka, J. E. P., Dryhurst, D. D., Ausio, J., Shabanowitz, J., & Hunt, D. F. (2005) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0503189102 · Cited by 373
Cited by
Protein Analysis by Shotgun/Bottom-up Proteomics
Zhang, Y., Fonslow, B. R., Shan, B., Baek, M.-C., & Yates, J. R. (2013) · Chemical Reviews · doi:10.1021/cr3003533 · Cited by 1,491
Ju, C., Yoon, G. M., Shemansky, J. M., Lin, D. Y., Ying, Z. I., Chang, J., Garrett, W. M., Kessenbrock, M., Groth, G., Tucker, M. L., et al. (2012) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.1214848109 · Cited by 637
Confident Phosphorylation Site Localization Using the Mascot Delta Score
Savitski, M. M., Lemeer, S., Boesche, M., Lang, M., Mathieson, T., Bantscheff, M., & Kuster, B. (2011) · Molecular & Cellular Proteomics · doi:10.1074/mcp.m110.003830 · Cited by 265
Catch me if you can: Mass spectrometry‐based phosphoproteomics and quantification strategies
Eyrich, B., Sickmann, A., & Zahedi, R. P. (2011) · PROTEOMICS · doi:10.1002/pmic.201000489 · Cited by 104
“[13] could confirm this phenomenon by using synthetic phosphopeptide libraries but demonstrated that the transfer reaction had no effect on site localization precision, since the extent of the rearrangement was insignificant.”
BackgroundFragmentation of Integral Membrane Proteins in the Gas Phase
Skinner, O. S., Catherman, A. D., Early, B. P., Thomas, P. M., Compton, P. D., & Kelleher, N. L. (2014) · Analytical Chemistry · doi:10.1021/ac500864w · Cited by 29
Metadata
- Authors
- Aguiar, M., Haas, W., Beausoleil, S. A., Rush, J., & Gygi, S. P.
- Venue
- Journal of Proteome Research
- Publisher
- American Chemical Society (ACS)
- Published
- 2010-04-16
- Volume
- 9
- Issue
- 6
- Pages
- 3103-3107
- ISSN
- 1535-3893 (ISSN-L)
- 1535-3907
- OpenAlex
- W2049049175
- Cited by
- 54
- References
- 3
- FWCI
- 4.84
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.