Interlaboratory Reproducibility of Selective Reaction Monitoring Assays Using Multiple Upfront Analyte Enrichment Strategies
Open accessThe DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.
Abstract
Over the past few years, mass spectrometry has emerged as a technology to complement and potentially replace standard immunoassays in routine clinical core laboratories. Application of mass spectrometry to protein and peptide measurement can provide advantages including high sensitivity, the ability to multiplex analytes, and high specificity at the amino acid sequence level. In our previous study, we demonstrated excellent reproducibility of mass spectrometry-selective reaction monitoring (MS-SRM) assays when applying standardized standard operating procedures (SOPs) to measure synthetic peptides in a complex sample, as lack of reproducibility has been a frequent criticism leveled at the use of mass spectrometers in the clinical laboratory compared to immunoassays. Furthermore, an important caveat of SRM-based assays for proteins is that many low-abundance analytes require some type of enrichment before detection with MS. This adds a level of complexity to the procedure and the potential for irreproducibility increases, especially across different laboratories with different operators. The purpose of this study was to test the interlaboratory reproducibility of SRM assays with various upfront enrichment strategies and different types of clinical samples (representing real-world body fluids commonly encountered in routine clinical laboratories). Three different, previously published enrichment strategies for low-abundance analytes and a no-enrichment strategy for high-abundance analytes were tested across four different laboratories using different liquid chromatography-SRM (LC-SRM) platforms and previously developed SOPs. The results demonstrated that these assays were indeed reproducible with coefficients of variation of less than 30% for the measurement of important clinical proteins across all four laboratories in real world samples.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Addona, T. A., Abbatiello, S. E., Schilling, B., Skates, S. J., Mani, D. R., Bunk, D. M., Spiegelman, C. H., Zimmerman, L. J., Ham, A.-J. L., Keshishian, H., et al. (2009) · Nature Biotechnology · doi:10.1038/nbt.1546 · Cited by 1,037
Agger, S. A., Marney, L. C., & Hoofnagle, A. N. (2010) · Clinical Chemistry · doi:10.1373/clinchem.2010.152264 · Cited by 143
Hoofnagle, A. N., Becker, J. O., Oda, M. N., Cavigiolio, G., Mayer, P., & Vaisar, T. (2012) · Clinical Chemistry · doi:10.1373/clinchem.2011.173856 · Cited by 140
Cited by
Collins, B. C., Hunter, C. L., Liu, Y., Schilling, B., Rosenberger, G., Bader, S. L., Chan, D. W., Gibson, B. W., Gingras, A.-C., Held, J. M., et al. (2017) · Nature Communications · doi:10.1038/s41467-017-00249-5 · Cited by 576
Self-citationClinical potential of mass spectrometry-based proteogenomics
Zhang, B., Whiteaker, J. R., Hoofnagle, A. N., Baird, G. S., Rodland, K. D., & Paulovich, A. G. (2019) · Nature Reviews Clinical Oncology · doi:10.1038/s41571-018-0135-7 · Cited by 210
Kennedy, J. J., Abbatiello, S. E., Kim, K., Yan, P., Whiteaker, J. R., Lin, C., Kim, J. S., Zhang, Y., Wang, X., Ivey, R. G., et al. (2014) · Nature Methods · doi:10.1038/nmeth.2763 · Cited by 184
Pottiez, G., Yang, L., Stewart, T., Song, N., Aro, P., Galasko, D. R., Quinn, J. F., Peskind, E. R., Shi, M., & Zhang, J. (2017) · Journal of Proteome Research · doi:10.1021/acs.jproteome.6b00829 · Cited by 37
“The SRM method not only provides highly selective and sensitive measurements of distinct proteins, but also demonstrates good precision and excellent reproducibility across different laboratories (24), (25).”
Drabovich, A. P., Saraon, P., Drabovich, M., Karakosta, T. D., Dimitromanolakis, A., Hyndman, M. E., Jarvi, K., & Diamandis, E. P. (2017) · doi:10.1101/120873
Self-citation
Metadata
- Authors
- Prakash, A., Rezai, T., Krastins, B., Sarracino, D., Athanas, M., Russo, P., Zhang, H., Tian, Y., Li, Y., Kulasingam, V., Drabovich, A., Smith, C. R., Batruch, I., Oran, P. E., Fredolini, C., Luchini, A., Liotta, L., Petricoin, E., Diamandis, E. P., Chan, D. W., Nelson, R., & Lopez, M. F.
- Venue
- Journal of Proteome Research
- Publisher
- American Chemical Society (ACS)
- Published
- 2012-07-03
- Volume
- 11
- Issue
- 8
- Pages
- 3986-3995
- ISSN
- 1535-3893 (ISSN-L)
- 1535-3907
- OpenAlex
- W2128564638
- Cited by
- 65
- References
- 3
- FWCI
- 3.46
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Interlaboratory Reproducibility of Selective Reaction Monitoring Assays Using Multiple Upfront Analyte Enrichment Strategies. https://app.cochat.ai/papers/10.1021/pr300014s
- The paper
- Prakash, A., Rezai, T., Krastins, B., Sarracino, D., Athanas, M., Russo, P., Zhang, H., Tian, Y., Li, Y., Kulasingam, V., Drabovich, A., Smith, C. R., Batruch, I., Oran, P. E., Fredolini, C., Luchini, A., Liotta, L., Petricoin, E., Diamandis, E. P., . . . Lopez, M. F. (2012). Interlaboratory Reproducibility of Selective Reaction Monitoring Assays Using Multiple Upfront Analyte Enrichment Strategies. Journal of Proteome Research. https://doi.org/10.1021/pr300014s
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.