Revisiting Peptide Identification by High-Accuracy Mass Spectrometry: Problems Associated with the Use of Narrow Mass Precursor Windows
The DOI matches its Crossref record; 5 of the 5 references it cites were found in a registry or an index.
Abstract
Peptide identification is increasingly achieved through database searches in which mass precursor tolerance is set in the ppm range. This trend is driven by the high resolution and accuracy of modern mass spectrometers and the belief that the quality of peptide identification is fully controlled by estimating the false discovery rate (FDR) using the decoy-target approach. However, narrowing mass tolerance decreases the number of sequence candidates, and several authors have raised concerns that these search conditions can introduce inaccuracies. Here, we demonstrate that when scores that only depend on one sequence candidate are used, decoy-based estimates of the number of false positive identifications are accurate even with an average number of candidates of just 200, to the point that remarkably accurate FDR predictions can be made in completely different search conditions. However, when scores that are constructed taking information from additional sequence candidates are used together with low precursor mass tolerances, the proportion of peptides incorrectly identified may become significantly higher than the FDR estimated by the target-decoy approach. Our results suggest that with this kind of score the high mass accuracy of modern mass spectrometers should be exploited by using wide mass windows followed by postscoring mass filtering algorithms.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Elias, J. E., & Gygi, S. P. (2007) · Nature Methods · doi:10.1038/nmeth1019 · Cited by 3,925
A draft map of the human proteome
Kim, M.-S., Pinto, S. M., Getnet, D., Nirujogi, R. S., Manda, S. S., Chaerkady, R., Madugundu, A. K., Kelkar, D. S., Isserlin, R., Jain, S., et al. (2014) · Nature · doi:10.1038/nature13302 · Cited by 2,198
Mass-spectrometry-based draft of the human proteome
Wilhelm, M., Schlegl, J., Hahne, H., Gholami, A. M., Lieberenz, M., Savitski, M. M., Ziegler, E., Butzmann, L., Gessulat, S., Marx, H., et al. (2014) · Nature · doi:10.1038/nature13319 · Cited by 1,820
Beausoleil, S. A., Villén, J., Gerber, S. A., Rush, J., & Gygi, S. P. (2006) · Nature Biotechnology · doi:10.1038/nbt1240 · Cited by 1,577
Assigning Significance to Peptides Identified by Tandem Mass Spectrometry Using Decoy Databases
Käll, L., Storey, J. D., MacCoss, M. J., & Noble, W. S. (2008) · Journal of Proteome Research · doi:10.1021/pr700600n · Cited by 607
Cited by
A Network of Macrophages Supports Mitochondrial Homeostasis in the Heart
Nicolás-Ávila, J. A., Lechuga-Vieco, A. V., Esteban-Martínez, L., Sánchez-Díaz, M., Díaz-García, E., Santiago, D. J., Rubio-Ponce, A., Li, J. L., Balachander, A., Quintana, J. A., et al. (2020) · Cell · doi:10.1016/j.cell.2020.08.031 · Cited by 762
Self-citationChen, Z.-L., Meng, J.-M., Cao, Y., Yin, J.-L., Fang, R.-Q., Fan, S.-B., Liu, C., Zeng, W.-F., Ding, Y.-H., Tan, D., et al. (2019) · Nature Communications · doi:10.1038/s41467-019-11337-z · Cited by 552
Torralba, D., Baixauli, F., Villarroya-Beltri, C., Fernández-Delgado, I., Latorre-Pellicer, A., Acín-Pérez, R., Martín-Cófreces, N. B., Jaso-Tamame, Á. L., Iborra, S., Jorge, I., et al. (2018) · Nature Communications · doi:10.1038/s41467-018-05077-9 · Cited by 375
A transmitochondrial sodium gradient controls membrane potential in mammalian mitochondria
Hernansanz-Agustín, P., Morales-Vidal, C., Calvo, E., Natale, P., Martí-Mateos, Y., Jaroszewicz, S. N., Cabrera-Alarcón, J. L., Acín-Pérez, R., López-Montero, I., Vázquez, J., et al. (2024) · Cell · doi:10.1016/j.cell.2024.08.045 · Cited by 34
Self-citation
Metadata
- Authors
- Bonzon-Kulichenko, E., Garcia-Marques, F., Trevisan-Herraz, M., & Vázquez, J.
- Venue
- Journal of Proteome Research
- Publisher
- American Chemical Society (ACS)
- Published
- 2014-12-22
- Volume
- 14
- Issue
- 2
- Pages
- 700-710
- ISSN
- 1535-3893 (ISSN-L)
- 1535-3907
- OpenAlex
- W2313102331
- Cited by
- 102
- References
- 5
- FWCI
- 1.63
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Revisiting Peptide Identification by High-Accuracy Mass Spectrometry: Problems Associated with the Use of Narrow Mass Precursor Windows. https://app.cochat.ai/papers/10.1021/pr5007284
- The paper
- Bonzon-Kulichenko, E., Garcia-Marques, F., Trevisan-Herraz, M., & Vázquez, J. (2015). Revisiting Peptide Identification by High-Accuracy Mass Spectrometry: Problems Associated with the Use of Narrow Mass Precursor Windows. Journal of Proteome Research. https://doi.org/10.1021/pr5007284
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.