A Proteomics Grade Electron Transfer Dissociation-Enabled Hybrid Linear Ion Trap-Orbitrap Mass Spectrometer
Open accessThe DOI matches its Crossref record; 8 of the 8 references it cites were found in a registry or an index.
Abstract
Here we detail the modification of a quadrupole linear ion trap-orbitrap hybrid (QLT-orbitrap) mass spectrometer to accommodate a negative chemical ionization (NCI) source. The NCI source is used to produce fluoranthene radical anions for imparting electron transfer dissociation (ETD). The anion beam is stable, robust, and intense so that a sufficient amount of reagents can be injected into the QLT in only 4-8 ms. Following ion/ion reaction in the QLT, ETD product ions are mass-to-charge (m/z) analyzed in either the QLT (for speed and sensitivity) or the orbitrap (for mass resolution and accuracy). Here we describe the physical layout of this device, parametric optimization of anion transport, an evaluation of relevant ETD figures of merit, and the application of this instrument to protein sequence analysis. Described proteomic applications include complex peptide mixture analysis, post-translational modification (PTM) site identification, isotope-encoded quantitation, large peptide characterization, and intact protein analysis. From these experiments, we conclude the ETD-enabled orbitrap will provide the proteomic field with several new opportunities and represents an advance in protein sequence analysis technologies.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Ong, S.-E., Blagoev, B., Kratchmarova, I., Kristensen, D. B., Steen, H., Pandey, A., & Mann, M. (2002) · Molecular & Cellular Proteomics · doi:10.1074/mcp.m200025-mcp200 · Cited by 5,574
Elias, J. E., & Gygi, S. P. (2007) · Nature Methods · doi:10.1038/nmeth1019 · Cited by 3,925
Peptide and protein sequence analysis by electron transfer dissociation mass spectrometry
Syka, J. E. P., Coon, J. J., Schroeder, M. J., Shabanowitz, J., & Hunt, D. F. (2004) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0402700101 · Cited by 2,370
Self-citationMass spectrometry–based proteomics turns quantitative
Ong, S.-E., & Mann, M. (2005) · Nature Chemical Biology · doi:10.1038/nchembio736 · Cited by 1,572
Large-scale phosphorylation analysis of mouse liver
Villén, J., Beausoleil, S. A., Gerber, S. A., & Gygi, S. P. (2007) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0609836104 · Cited by 730
Feeder-independent culture of human embryonic stem cells
Ludwig, T. E., Bergendahl, V., Levenstein, M. E., Yu, J., Probasco, M. D., & Thomson, J. A. (2006) · Nature Methods · doi:10.1038/nmeth902 · Cited by 681
Protein identification using sequential ion/ion reactions and tandem mass spectrometry
Coon, J. J., Ueberheide, B., Syka, J. E. P., Dryhurst, D. D., Ausio, J., Shabanowitz, J., & Hunt, D. F. (2005) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0503189102 · Cited by 373
Self-citationPhanstiel, D., Brumbaugh, J., Berggren, W. T., Conard, K., Feng, X., Levenstein, M. E., McAlister, G. C., Thomson, J. A., & Coon, J. J. (2008) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0710515105 · Cited by 166
Self-citation
Cited by
Protein Analysis by Shotgun/Bottom-up Proteomics
Zhang, Y., Fonslow, B. R., Shan, B., Baek, M.-C., & Yates, J. R. (2013) · Chemical Reviews · doi:10.1021/cr3003533 · Cited by 1,491
Exosomes: proteomic insights and diagnostic potential
Simpson, R. J., Lim, J. W., Moritz, R. L., & Mathivanan, S. (2009) · Expert Review of Proteomics · doi:10.1586/epr.09.17 · Cited by 1,108
Michalski, A., Damoc, E., Hauschild, J.-P., Lange, O., Wieghaus, A., Makarov, A., Nagaraj, N., Cox, J., Mann, M., & Horning, S. (2011) · Molecular & Cellular Proteomics · doi:10.1074/mcp.m111.011015 · Cited by 832
Self-citationZubarev, R. A., & Makarov, A. (2013) · Analytical Chemistry · doi:10.1021/ac4001223 · Cited by 658
Self-citationTop Down proteomics: Facts and perspectives
Catherman, A. D., Skinner, O. S., & Kelleher, N. L. (2014) · Biochemical and Biophysical Research Communications · doi:10.1016/j.bbrc.2014.02.041 · Cited by 507
Value of Using Multiple Proteases for Large-Scale Mass Spectrometry-Based Proteomics
Swaney, D. L., Wenger, C. D., & Coon, J. J. (2010) · Journal of Proteome Research · doi:10.1021/pr900863u · Cited by 474
Self-citationPhosphopeptide fragmentation and analysis by mass spectrometry
Boersema, P. J., Mohammed, S., & Heck, A. J. R. (2009) · Journal of Mass Spectrometry · doi:10.1002/jms.1599 · Cited by 362
Zhang, Z., Wu, S., Stenoien, D. L., & Paša-Tolić, L. (2014) · Annual Review of Analytical Chemistry · doi:10.1146/annurev-anchem-071213-020216 · Cited by 323
Frese, C. K., Altelaar, A. F. M., Hennrich, M. L., Nolting, D., Zeller, M., Griep-Raming, J., Heck, A. J. R., & Mohammed, S. (2011) · Journal of Proteome Research · doi:10.1021/pr1011729 · Cited by 312
Self-citationDecision tree–driven tandem mass spectrometry for shotgun proteomics
Swaney, D. L., McAlister, G. C., & Coon, J. J. (2008) · Nature Methods · doi:10.1038/nmeth.1260 · Cited by 312
Self-citationPalaniappan, K. K., & Bertozzi, C. R. (2016) · Chemical Reviews · doi:10.1021/acs.chemrev.6b00023 · Cited by 278
Mass Spectrometry-Based Detection and Assignment of Protein Posttranslational Modifications
Doll, S., & Burlingame, A. L. (2015) · ACS Chemical Biology · doi:10.1021/cb500904b · Cited by 261
Mucin‐type O‐glycosylation – putting the pieces together
Jensen, P. H., Kolarich, D., & Packer, N. H. (2010) · The FEBS Journal · doi:10.1111/j.1742-4658.2009.07429.x · Cited by 252
Human Pumilio Proteins Recruit Multiple Deadenylases to Efficiently Repress Messenger RNAs
Van Etten, J., Schagat, T. L., Hrit, J., Weidmann, C. A., Brumbaugh, J., Coon, J. J., & Goldstrohm, A. C. (2012) · Journal of Biological Chemistry · doi:10.1074/jbc.m112.373522 · Cited by 205
“Peptides were then analyzed using nanoflow liquid chromatography (Waters) coupled to an ETD-enabled hybrid linear ion traporbitrap mass spectrometer (Thermo Scientific) via electrospray (65).”
MethodSelf-citationMazur, M. T., Cardasis, H. L., Spellman, D. S., Liaw, A., Yates, N. A., & Hendrickson, R. C. (2010) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0910776107 · Cited by 87
“laboratories to acquire high-resolution full-scan andETD-MS/MS tandem mass spectra for intact proteins with molecular weights in the range of 5–50 kD (16).”
BackgroundRecent Developments in Gas-Phase Ion/Ion Reactions for Analytical Mass Spectrometry
Foreman, D. J., & McLuckey, S. A. (2020) · Analytical Chemistry · doi:10.1021/acs.analchem.9b05014 · Cited by 65
Expanding the mass range for UVPD-based native top-down mass spectrometry
Greisch, J.-F., Tamara, S., Scheltema, R. A., Maxwell, H. W. R., Fagerlund, R. D., Fineran, P. C., Tetter, S., Hilvert, D., & Heck, A. J. R. (2019) · Chemical Science · doi:10.1039/c9sc01857c · Cited by 47
Metadata
- Authors
- McAlister, G. C., Berggren, W. T., Griep-Raming, J., Horning, S., Makarov, A., Phanstiel, D., Stafford, G., Swaney, D. L., Syka, J. E. P., Zabrouskov, V., & Coon, J. J.
- Venue
- Journal of Proteome Research
- Publisher
- American Chemical Society (ACS)
- Published
- 2008-07-10
- Volume
- 7
- Issue
- 8
- Pages
- 3127-3136
- ISSN
- 1535-3893 (ISSN-L)
- 1535-3907
- OpenAlex
- W1988791332
- Cited by
- 145
- References
- 8
- FWCI
- 10.05
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.