Large-Scale Multiplexed Quantitative Discovery Proteomics Enabled by the Use of an 18O-Labeled “Universal” Reference Sample
Open accessThe DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Abstract
The quantitative comparison of protein abundances across a large number of biological or patient samples represents an important proteomics challenge that needs to be addressed for proteomics discovery applications. Herein, we describe a strategy that incorporates a stable isotope (18)O-labeled "universal" reference sample as a comprehensive set of internal standards for analyzing large sample sets quantitatively. As a pooled sample, the (18)O-labeled "universal" reference sample is spiked into each individually processed unlabeled biological sample and the peptide/protein abundances are quantified based on (16)O/(18)O isotopic peptide pair abundance ratios that compare each unlabeled sample to the identical reference sample. This approach also allows for the direct application of label-free quantitation across the sample set simultaneously along with the labeling-approach (i.e., dual-quantitation) since each biological sample is unlabeled except for the labeled reference sample that is used as internal standards. The effectiveness of this approach for large-scale quantitative proteomics is demonstrated by its application to a set of 18 plasma samples from severe burn patients. When immunoaffinity depletion and cysteinyl-peptide enrichment-based fractionation with high resolution LC-MS measurements were combined, a total of 312 plasma proteins were confidently identified and quantified with a minimum of two unique peptides per protein. The isotope labeling data was directly compared with the label-free (16)O-MS intensity data extracted from the same data sets. The results showed that the (18)O reference-based labeling approach had significantly better quantitative precision compared to the label-free approach. The relative abundance differences determined by the two approaches also displayed strong correlation, illustrating the complementary nature of the two quantitative methods. The simplicity of including the (18)O-reference for accurate quantitation makes this strategy especially attractive when a large number of biological samples are involved in a study where label-free quantitation may be problematic, for example, due to issues associated with instrument platform robustness. The approach will also be useful for more effectively discovering subtle abundance changes in broad systems biology studies.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Protein biomarker discovery and validation: the long and uncertain path to clinical utility
Rifai, N., Gillette, M. A., & Carr, S. A. (2006) · Nature Biotechnology · doi:10.1038/nbt1235 · Cited by 1,867
Mass spectrometry–based proteomics turns quantitative
Ong, S.-E., & Mann, M. (2005) · Nature Chemical Biology · doi:10.1038/nchembio736 · Cited by 1,572
Cited by
Comparative analysis of proteome and transcriptome variation in mouse
Ghazalpour, A., Bennett, B., Petyuk, V. A., Orozco, L., Hagopian, R., Mungrue, I. N., Farber, C. R., Sinsheimer, J., Kang, H. M., Furlotte, N., et al. (2011) · PLoS Genetics · doi:10.1371/journal.pgen.1001393 · Cited by 624
“We utilized the differential labeling technique as put forth by Qian and colleagues where the label free samples are combined with an internal control labeled with heavy isotope [15].”
BackgroundMethodInfluentialSelf-citationZhu, Y., Piehowski, P. D., Zhao, R., Chen, J., Shen, Y., Moore, R. J., Shukla, A. K., Petyuk, V. A., Campbell-Thompson, M., Mathews, C. E., et al. (2018) · Nature Communications · doi:10.1038/s41467-018-03367-w · Cited by 587
Self-citationMass spectrometry-based proteomics: existing capabilities and future directions
Angel, T. E., Aryal, U. K., Hengel, S. M., Baker, E. S., Kelly, R. T., Robinson, E. W., & Smith, R. D. (2012) · Chemical Society Reviews · doi:10.1039/c2cs15331a · Cited by 441
Self-citationCurrent trends in quantitative proteomics
Elliott, M. H., Smith, D. S., Parker, C. E., & Borchers, C. (2009) · Journal of Mass Spectrometry · doi:10.1002/jms.1692 · Cited by 271
Yildiz, P., & Ozcan, S. (2023) · Talanta · doi:10.1016/j.talanta.2023.124878 · Cited by 2
Metadata
- Authors
- Qian, W.-J., Liu, T., Petyuk, V. A., Gritsenko, M. A., Petritis, B. O., Polpitiya, A. D., Kaushal, A., Xiao, W., Finnerty, C. C., Jeschke, M. G., Jaitly, N., Monroe, M. E., Moore, R. J., Moldawer, L. L., Davis, R. W., Tompkins, R. G., Herndon, D. N., Camp, D. G., Smith, R. D., & Program, T. I. A. T. H. R. T. I. L. S. C. R.
- Venue
- Journal of Proteome Research
- Publisher
- American Chemical Society (ACS)
- Published
- 2008-11-21
- Volume
- 8
- Issue
- 1
- Pages
- 290-299
- ISSN
- 1535-3893 (ISSN-L)
- 1535-3907
- OpenAlex
- W2093348051
- Cited by
- 55
- References
- 2
- FWCI
- 3.12
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.